JOY Fancoil 5DO (85..260 V ~)
Modern design, flush mounting fan coil room thermostat. Used for individual control of temperature in commercial and residential buildings. It is tailored for two-pipe and four-pipe fan coil units with two-wire electric valves. The device combines a modern design with a 2,5” LCD and a touchsensitive surface, 3 time program options each with 4 time periods options.
JOY Fancoil EC AO2DO (85..260 V ~)
Modern fan coil room thermostat to control fan coil units with EC fans. It is suitable for 2- and 4-pipe systems. It has 2 relays and 1 analogue output 0-10V (heating valve, cooling valve and EC fan). The device combines a modern design with a 2,5” LCD and a touch-sensitive surface, 3 time program options each with 4 time periods options.
JOY Fancoil EC 3AO (24 V ~/=)
Modern design, flush mounting fan coil room thermostat. Used for individual control of temperature in commercial, industrial and residential buildings. It is tailored for two-pipe and four-pipe fan coil units with two-wire electric valves or controlling a 6-way valve. The device combines a modern design with a 2,5” LCD and a touch-sensitive surface, 3 time program options each with 4 time periods options.
SECURITY ADVICE – CAUTION
The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment.
CAUTION! Risk of electric shock due to live components within the enclosure, especially devices with mains voltage supply (usually between 90..265 V).
Please comply with
Declaration of conformity
The declaration of conformity of the products can be found on our website https://www.thermokon.de/
NOTES ON DISPOSAL
As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled and not disposed of as domestic waste. Please note the relevant regulations for local disposal.
MOUNTING ADVISE ROOM SENSORS
The Accuracy of the room sensors are influenced by the technical specifications as well as the positioning and the installation type.
During Assembly:
Assembly not recommendet in…
MOUNTING ADVICE JOY
Plasterboard boxes shall be covered by wall paper or paint to avoid that the plasterboard box’s front rim will be partially visible underneath JOY. Maybe consider using white plasterboard boxes (i.e. Kaiser 9063-77).
APPLICATION NOTICE
NOTES ON THE UPDATE FUNCTION
Configuration software:
Config | Windows 10 is required to use the uConfig configuration software The JOY room thermostat can be parameterised using the uConfig configuration software. An SD card is used to transfer the created configuration file to the device. The installer for the configuration software can be found in the Download-Section on our website. The installer retrieves all necessary files and plug-ins from our web server. In this version an update function is integrated in the software. Download-Section
JOY Fancoil 5DO | JOY Fancoil EC AO2DO | JOY Fancoil EC 3AO
Measuring values | temperature, humidity (optional) | |||
Measuring range temp. | 0..+50 °C | |||
Accuracy temperature | ±1 K (typ. bei 21 °C) | |||
Measuring range humidity (optional) | 0..100% rH non-condensing | |||
Accuracy humidity (optional) | ±2% between 10..90% rH (typ. at 21 °C) | |||
Control function | setpoint adjustment +0..+50 °C, fan stages | |||
Display | LCD 2,5“, 240×160 px, white backlighting | |||
Functions | integrated PI- and 2-point-/ 3-point-controllers, 2nd control loop: 2-point controller | |||
Enclosure | PC and glass, optional black or white | |||
Protection | IP30 according to EN 60529 | |||
Connection electrical | Terminal 1..8 terminal block max. 1,5 mm² | Terminal 9..12 terminal block max. 1.0 mm² | ||
Ambient condition | 0..+50 °C, max. 85% rH non-condensing | |||
Weight | 195 g | |||
Mounting | flush mounted with standard EU box (Ø=60 mm) | |||
» JOY Fancoil 5DO | ||||
Output switch contact | 3x normally open contacts (fan speed), 240 V, load max. 3 A | 2x normally open contacts (heating/cooling), 240 V, load max. 500 mA | ||
Power supply | 85..260 V ~ | |||
Power consumption | max. 2,5 VA (260 V ~) | |||
Inputs | DI1 input for NTC 10 K or floating contact | DI2 digital input for non-floating contact (230 V ~) | DI3 digital input for floating contact | |
» JOY Fancoil EC AO2DO | ||||
Output voltage | 1x 0..10 V, max. load 5 mA, EC FAN control | |||
Output switch contact | 2x normally open contacts (heating/cooling), 240 V max. load 500 mA | |||
Power supply | 85..260 V ~ | |||
Power consumption | max. 3 VA (260 V ~) | |||
Inputs | DI1 input for NTC 10 K or floating contact | DI2 digital input for non-floating contact (230 V ~) | DI3 digital input for floating contact | |
» JOY Fancoil EC 3AO | ||||
Output voltage | 3x 0..10 V, max. load 5 mA, EC Fan control, heating & cooling or control 6-way valves (configurable via Software) | |||
Power supply | 24 V = (±10%) oder 24 V ~ (±10%) SELV | |||
Power consumption | max. 2,5 W (24 V =) | |||
Inputs | DI1 input for NTC 10 K or floating contact | Di 2 | DI 3 2 digital inputs for non-floating contact |
Fan stages (all types)
In automatic mode the fan speed is linked to the controller. The assignment of the fan stage to the control (heating / cooling, only heating, only cooling) is freely selectable. To ensure that the fan motor starts reliably, a period of time can be configured in which the fan starts with maximal value. Using one or more time channels, the fan control have to be set per timechannel and per period. Via the touch surface the user has the option to override the settings of the device every time. When the next time channel starts, the fan speed is set to the configured value. The fan is set to automatic mode when the user changes the occupancy state (occupied↔unoccupied).
Heating/ cooling with PI-controller (PWM) (only 5DO and EC AO2DO)
The time response of the PI control loop depends on the control parameters xp for the proportional area and tn for the reset time of the integral range. In case of an error, the P portion immediately changes the position value proportionally to the error variable, while the integral portion takes effect after a certain time. The resulting actuating variable is output as a pulse-width-modulated signal directly to the outputs.
Heating/ cooling with 2-point-/ 3-point-controller (only 5DO and EC AO2DO)
In the case of temperature control, the 2-point controller only knows the switching states heating ON and heating OFF. The 3-point controller also knows the switching state of cooling. Two – and three-point controller work with a hysteresis.
Heating/ cooling with PI-controller (0..10 V) (only EC 3AO and EC AO2DO)
The time response of the PI control loop depends on the control parameters xp for the proportional area and tn for the reset time of the integral range. In case of an error variable, the P portion immediately changes the position value proportionally to the error variable, while the integral portion takes effect after a certain time. The resulting manipulated variable is output as an analogue 0..10 V signal directly to the outputs.
EC Fan automatic mode with PI-controller (only EC 3AO and EC AO2DO)
(for EC AO2DO with two-point/three-point controller, the temperature range for controlling the 0..10 V EC fan is parameterised separately) The 0..10 V (0..100%) control of the fan is proportional to the calculated manipulated variable of the PI controller. example: Calculated actuating variable 65% = Fan control with 6,5 V Calculated actuating variable 22% = Fan control with 2,2 V
EC Fan manual with PI-controller (only EC 3AO and EC AO2DO)
Up to 5 steps (stages) can be set using the configuration software. The set number is divided linearly to the manipulated variable of 0..100%. example: max. steps (stages) = 5
Value Screen
Header (value/ symbol display)
On the touch surface, there are adjustment options for setpoint and fan speed regulation.
While pressing these buttons, the white ring-LED of the Power-button lights up for visual feedback.
Standby mode (not compatible with Keycard-switch function)
In standby mode, the display and all outputs are switched off (controller deactivated). The frost and heat protection monitoring remains active
To access the diagnostics menu, select the header in the start screen of the parameter menu, and press the ENTER key. Here you will find various information, such as device type, software version, state of the inputs and outputs and controller state (current manipulated variable).
Access to Parameter menu
Press buttons for 3 seconds simultaneously
MENU → TIME CHANNELS
In the Time Channels menu, setpoint and timer can be set. Up to 3 time channels with 4 time periods each can be parameterized. The time channels are prioritized. Channel 3 has the highest priority. After selecting the line of the time channel to be edited, the next submenu is called up with the “Right” key. It is possible to set any time period within one week in the first two lines with the “Left” (-)/ “Right”(+) keys. In addition, the ECO mode is available in the menu sections. In ECO mode, the dead zone between heating and cooling is automatically set to the ECO dead zone configured in the “General Settings” menu (default: 10 K).
MENU → INPUTS
Up to 3 inputs are configurable for functions such as windows contact, dew point, occupancy, change-over or external sensor option. The overview of possible combinations can be found in the software specification of the JOY
MENU → TIME/DATE
Time, Date and display format can be configured in the menu settings. The room thermostat is equipped with a real-time clock so that it automatically adjusts for daylight-saving time. This function can be disabled in the datetime settings.
MENU → SENSOR SETTINGS
Offset correction for internal and external sensor value. The temperature display can also be changed from °C to °F.
Common device settings:
Brightness
Configuration of the LCD brightness/ LED ring brightness during button operation/ usage.
Valve protection
A valve protection function actuates the heating and cooling valves regularly to prevent locking during non-usage times. The function is executed fridays at 11.00 (heating valve) and 11.15 (cooling valve). The corresponding valve is triggered for 5 minutes, if not activated during the last 96 hours.
ECO deadband
The dead band can be adjusted (default 10.0 K) further information in the software specification file
Factory setting
By selecting “Factory setting”, the room thermostat will be reset and restore the device to factory default settings.
ACCESSORIES (OPTIONAL)
DOWNLOAD MANUALS:
THERMOKON Digital Room Thermostat PRODUCT DATA SHEET
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…