terneo vt thermostat is designed to maintain constant temperature from 0 to 35 °С in electric heating systems. According to data from the internal temperature sensor, the thermostat turns off the heating when the desired temperature is reached and turns on when it decreases by 1 °C.
Adjustment range | 0…35 °С |
Maximum load current (for category AC-1) | 16 А |
Rated load capacity (for category AC-1) | 3 000 VА |
Input voltage | 230 V ±10 % |
Weight in the complete set | 0,18 kg ±10 % |
Overall dimensions (w × h × d) | 75 × 75 × 39 mm |
Temperature sensor | NTC thermo-resistor 10 kOhm 25 °C (R10) |
Number combinations under heat, at least | 50 000 cycles |
Number of combinations without heating, no less than | 20 000 000 cycles |
Temperature hysteresis | 1 °С |
Degree of protection GOST14254 | IP20 |
IMPORTANT. Before the installation and operation of the device, please read by the end of this document. This will help to avoid possible danger, mistakes and misunderstandings.
RELIABILITY OF THE POWER RELAY provides protection against frequent switching in the thermostat. If there was less than 1 minute between relay switching, the relay activation will be delayed, marking the countdown with a flashing dot.
NON-VOLATILE THERMOSTAT STORAGE saves all settings in the event of a power outage.
THE EFFECT OF INTERNAL HEATING OF COMPONENTS ON TEMPERATURE MEASUREMENT IS TAKEN INTO ACCOUNT BY THE THERMOSTAT CORRECTION SYSTEM. Be sure to enter data on the connected load power in settings (Tab. 1). After a short-term voltage outage, it may take some time to stabilize the measurements (no more than 50 minutes).
Power voltage (230 V ± 10 %, 50 Hz) is supplied to terminals 4 (neutral, N) and 5 (phase, L).
Load (connecting wires from heating element) is connected to terminals 3 and 6.
THE THERMOSTAT IS MOUNTED AND CONNECTED after the installation and load testing.
For installation you must:
The thermostat terminals are designed for a wire with section not more than 2,5 mm . To reduce the mechanical loads on the terminals it is desirable to use a soft wire. The wires are tightened in the terminals using
a screwdriver with a blade width no more than 3 mm. The terminals should be tighten with torque 0,5 N·m. Use of aluminum is not desirable The sections of the wires, which is connected to the thrmostat, must be at least copper 2 × 1,0 mm. The screwdriver with a blade width more than 3 mm can cause mechanical damage to the terminals. This may result in the loss of right for warranty. It is important to remember that it is desirable to place the on the inner wall of the room. It is recommended to store out the thermostat of direct sunlight and drafts (Fig. 1). It is necessary for the thermostat to switch the current to no more than 2/3 of the maximum current specified in the specification. If the current exceeds this value, the load must be connected through a contactor (magnetic actuator, power relay), which is optimized for this current (Wiring 2).
SET THE LOAD POWER TO 100 W WHEN CONTROLLED VIA CONTACTOR for correct measurement of air temperature by thermostat.
The warranty for devices is valid for from the date of sale, provided that the instructions are followed. The warranty period for products without a warranty certificate is counted from the date of production. terneo 36 months If your device is not working properly, we recommend that you first read the section «Possible problems». If you cannot find an answer, contact Service Center. In most cases, these actions resolve all issues. If you continue to have issues with the device, please send it to a Service Center or to the store where you purchased the device. If your device is defective due to our fault, we will repair or replace it under warranty within 14 business days. Please see the full text of the warranty and the data you need to send to your Service Center on the website https://www.ds-electronics.com.ua/en/. If you have a warranty case, please, contact the General distributor in your area.
WARRANTY CARD
Hold down
Preset temperature (factory setting 25 °С)
When button
Switching to sleep mode
Button blocking (child and public protection)
Table 1. FUNCTION MENU
Heating temperature does not correspond to the settings
Load is off, screen and indicator are off
The load does not work, the
Every 5 seconds the screen displays «Ert»
Manufacturer and vendor: DS ELECTRONICS, LTD
SERVICE CENTER CONTACT:
Download Manual:
Terneo VT SMART Thermostat Technical Datasheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…