The thermoregulator terneo st is designed to maintain a constant temperature of 5…40 °C in underfloor heating systems based on:
According to the data from the temperature sensor placed in the floor, the thermostat controls the heating: it turns off the heating, when the desired temperature is reached and turns it on, when it drops by 1 °C.
Adjustment range | 5…40 °С |
Maximum load current (for category AC-1) | 16 А |
Rated load capacity (for category AC-1) | 3 000 VА |
Input voltage | 230 V ±10 % |
Weight in the complete set | 0,18 kg ±10 % |
Basic mounting dimensions | 75 × 75 × 39 mm |
Temperature sensor | NTC thermo-resistor 10K OM at 25 °C (R10) |
The length of the sensor connected cable | 3 m |
Number combinations under heat, at least | 50 000 cycles |
Number of combinations without heating, no less than | 20 000 000 cycles |
Temperature hysteresis | 1 °С |
Measured temperature range | –28…+75 °С |
Degree of protection GOST14254 | IP20 |
IMPORTANT. Before the installation and operation of the device, please read by the end of this document. This will help to avoid possible danger, mistakes and misunderstandings.
RELIABILITY OF THE POWER RELAY: provides protection against frequent switching in the thermostat. If there was less than 1 minute between relay switching, the relay activation will be delayed, marking the countdown with a flashing dot.
NON-VOLATILE THERMOSTAT STORAGE
saves all settings in the event of a power outage.
Thermoregulator supports two types of sensors: analog sensor (R10) or digital sensor (D18).
Analog sensor is connected to terminals 1 and 2. Wires colors are of no importance.Digital sensor is connected to terminal 1 using white wire and to terminal 2 using blue wire. If the thermoregulator changes to Percentage load control mode (page 7), try connecting to terminal 2 using blue wire and to terminal 1 using white wire. If, at both attempts, the thermoregulator does not see the sensor, contact the Service Center.
Power voltage (230 V ± 10 %, 50 Hz) is supplied to terminals 4 and 5, at that phase (L) is determined by indicator and is connected to terminal 5, and neutral (N) — to terminal 4.
Load (connecting wires from heating element) is connected to terminals 3 and 6.
THE THERMOSTAT IS MOUNTED AND CONNECTED after the installation and load testing
IN THE CASE OF INCORRECT WIRING, is possible failure of the thermostat. make sure that external sensor and mains voltage are connected correctly.
Wiring 1. Connection of the circuit breaker and SSD
To protect a people against electric shock leakage is installed the SSD (safety shutdown device). This event is obligatory when installing floor heating in wet areas. For working of SSF the heating cable screen must be grounded (connected to the protective conductor PE) or, if there is two-wire network, it is necessary to make protective neutral earthing. That is to connect the screen to a zero before SSF. In Wiring 2 protective neutral earthing is shown with dotted line.
The thermoregulator is mounted in the standard mounting box 60 mm in diameter, with mounting screws.
For installation you must:
The thermoregulator terminals are designed for a wire with section not more than 2,5 mm . To reduce the mechanical loads on the terminals it is desirable to use a soft wire. The ends of the wires must be cleaned and crimped with ferrules with insulation. The wires are tightened in the terminals using a screwdriver with a blade width no more than 3 mm. The screwdriver with a blade width more than 3 mm can cause mechanical damage to the terminals. This may result in the loss of right for warranty. The terminals should be tighten with torque 0,5 N·m.
The sensor mounting should provide its easy replacement in a future. The mounting tube (reinforced-plastic tube Ø 16 mm) is brought from the mounting box with the thermoregulator to the area heated for about
0,5 m. The tube bends and length should provide unobstructed movement of the sensor. The end of the tube brought to the heated area should be thoroughly insulated by for instance an insulating tape to protect against grout. The sensor is put in the tube after the covering setting.
If necessary the sensor connecting wires may be shortened and extended (for not more than 20 m). It is prohibited to use two strands of multistrand cable, which is used for the heater power supply, for length extension. The best solution is to use a separate cable brought to the sensor mounted in a separate tube. There should be no power cables near sensor connecting wire, as they may interfere.
Figure 1. Mounting the thermo stat and «warm floor system
MOUNTING OF THE SENSOR MUST BE PERFORMED SO THAT IT WAS POSSIBLE TO EASILY REPLACE IT.
Wiring 2. Wiring and simplified internal circuit
THE RESISTANCE OF THE SENSOR at different temperatures
Switching on/ switching off
Press «+» button and hold for 4 seconds, 3 dashes will appear on the screen one by one. After appearing on the screen «on» / «oFF» release the button.
After switching on the thermoregulator starts to display the temperature of the sensor. On-load voltage is supplyed when the temperature is below the setpoint temperature. Whereby the indicator light turns red. At the first start-up, the setpoint temperature is 25 °C.
In the waiting mode (when the buttons aren`t currently being used) the brightness of the indicator and the screen will be reduced to 30 %.
After switch-off thermoregulator switches to the sleep mode. To switch off thermoregulator completely you should switch off the circuit breaker.
factory setting 25 °С)
When button «+» or «+» is pressed thermoregulation switches to the mode of display and change of preset temperature. While flashing, if button «+» is pressed tpreset will be increased, if button «–» is pressed tpreset will be decreased. In 3 sec after the last press thermoregu lator switches to sensor temperature display and if it is below the preset temperature the voltage is supplied to load.
Function menu (table 1)
Hold down «–» button for a certain number of seconds to view desired menu item. Then change the parameter with the «+» and «–» buttons.
3 seconds after the last pressing, the thermoregulator will automatically return to the sensor temperature display.
Button blocking
(child and public protection)
In order to enable (disable) button blocking press the «+» and «–» buttons at the same time for 6 seconds till the «Loc» («oFF») sign appears on the screen.
The internal overheating protection
Letters «ЗНЕ» are displayed on screen.
Thermoregulator has switched to percentage control with the sensor being connected.
Table 1. FUNCTION MENU
Percent control (factory setting 50%)
At the first switching on, this value is 50 % «50П», while the load in the 30-minute time interval will be turned off for 15 mi-nutes.
Heating temperature control is not available in this mode.
Neither indicator nor the screen light up upon thermoregulator switch-on.
ADDITIONAL INFORMATION
WARRANTY CARD
Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU
Manufacturer and vendor: DS ELECTRONICS, LTD
SERVICE CENTER CONTACT
+38 (091) 481-91-81
Viber WhatsApp Telegram
support@dse.com.ua
Download Manual:
Terneo ST SMART Thermostat Operation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…