This brochure will provide you with the information you need to benefit the most from your tekmarNet® thermostat. Please visit www.tekmarcontrols.com for more detailed information on this or any other tekmar product. This thermostat provides heating for one zone in your building. It will maintain your air temperature with an on board room sensor. Floor temperature control may also be enabled in this thermostat when a floor sensor is installed. This thermostat can lower its temperature setting at night or when you are away from the house.
The touchscreen of this thermostat makes it easy to change commonly used settings. Touch any item to adjust the setting. You will hear a sound each time you touch the display. When you are finished making changes, touching the home button will return to the home screen. If you do not touch the screen for 3 seconds, the home screen is automatically displayed.
tekmarNet® Thermostat 552 Home Screen
Display of the time, schedule, and away key on the home screen is optional and can be turned on or off in the programming menus. To enter the programming menus, press and hold the Home button for 3 seconds.
Display Symbols
This thermostat will display symbols on its screen in order to indicate what mode it is in, what temperature it is operating at, or what equipment it is trying to turn on. This section describes each of those symbols.
Adjust the Temperature
To change the set temperature, touch the
The temperature is not adjustable if the thermostat is in the Away scene, the Off mode or has been set to the “Limited” or “Secure” access level by the installer.
Adjust the Temperature – Temporary Hold
A temporary hold allows a user to change the temperature for a period of time and then automatically return to the permanent temperature setting. This is especially useful in commercial buildings that are in use for short amounts of time. When selected, touching the up or down arrows changes the temperature for either 3, 6, 9 or 12 hours. If the thermostat is using a schedule, ‘Schd’ provides a temporary hold until the next scheduled event time. After the temporary hold time expires, the thermostat returns to normal operation. By default, the temporary hold feature is off.
Mode Heat or Off Heating
the operation can easily be turned off by selecting the “Off” mode. Touch the Mode key on the screen to change between Heat and Off. The temperature is not adjustable while the thermostat is off. If near-freezing temperatures are detected the system will operate to maintain 40°F (4.5°C), even in the Off mode.
Secondary Temperature Display
This thermostat can display the outdoor, floor or room set temperature in the smaller number area at the top right of the screen. To toggle the item currently displayed, touch the secondary temperature. Display of the floor or outdoor temperature requires a connection to an external floor or outdoor air sensor.
To change the current time, touch the clock on the display.
This thermostat is capable of running at a lower temperature setting when you are asleep or out of the building. When the schedule setting is on, day
Going Away Setting
This thermostat can save additional energy while you are away by operating at a lowered temperature. To enable this feature, touch “Going Away” on the screen. This is only available when the Away Key has been turned on in the Scene menu.
Access Levels
This thermostat has access levels. It will typically be installed and programmed by a heating professional and then locked in a “User”, “Limited”, or “Secure” access level. System critical settings will not be available for adjustment. For more information on these settings, please consult your installing contractor or this product’s Installation and Operation Manual. This brochure focuses on settings available to the “User”.
To Enter the Programming Menus
Press and hold the Home button for 3 seconds to enter the programming menus.
Select a Programming Menu
Setting Items
Screen Clean Menu
Entering the Screen Clean menu gives you 30 seconds to clean the thermostat and display with a moist cloth. Do not use solvents to clean the thermostat.
Entering the Set Temp menu allows you to permanently change both the day
Floor Temperature Only
If the air sensor has been disabled, the thermostat will only maintain floor temperature and ignore air temperature. This operation is recommended for areas such as bathrooms to ensure that tile floors are warm to the touch.
Floor and Air Temperature
If the air sensor is turned on and a floor sensor is connected, the thermostat will maintain your desired air temperature as well as a minimum floor temperature. This operation is recommended for areas with large windows that allow the sun to shine into a room and keep it warm without the need for heat. This can allow the floors to cool off during the afternoon. When the sun goes down, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room. This operation is also recommended for rooms with hardwood floors. The floor maximum setting prevents damage to the wood floor from overheating.
Set date, month, and year
Required for daylight savings time.
Daylight Save
Automatic daylight saving time update for the spring and fall.
Time Mode
Select either 12 or 24-hour time format.
Clock
Select on to display the time clock in the Home menu (available when schedules are not used).
Schedule Menu Settings
Lowering the room temperature setting reduces the amount of fuel required to heat the building resulting in energy savings. When operating on a programmable schedule, a
Display | Action |
| Day temperature |
| Night temperature |
This thermostat can operate on a programmable schedule in order to automatically lower the room temperature setting. Options include:
Schedules with four events per day are common for residential use while two events per day are common for commercial installations.
Schedule Menu Settings (Continued)
The schedules can be repeated every:
A 7-day schedule allows a unique time to be set to change the temperature for each day of the week. The schedule also includes a “SKIP” option that allows the programmable schedule to skip a temperature change and remain at the previous temperature setting. The “SKIP” setting can be found between 11:50 PM (23:50 hours) and 12:00 AM (0:00 hours). When a programmable schedule is selected, there is a time delay for the room to warm up from the temperature to the
Display Menu Settings
Units
Select temperature units in degrees Fahrenheit or Celsius.
Backlight Options
Select how the display backlight operates.
ON = The display is always at full brightness.
DIM
DIM = When the thermostat is not in use, the display is dim while the schedule or scene is . The display backlight is off when the schedule or scene is
ON
OFF = The display backlight is always off.
Secondary Item
Select whether the outdoor or floor temperature is shown in the upper right-hand corner in the Home menu.
Scene Menu Settings
Scenes
Scenes provide system-wide overrides to save energy. Select whether scenes are not used (none) or if the away scene is available.
Away Key
If scenes are available, select if the away key is available or not. When used in conjunction with a tekmarNet® system control to operate the heating appliance, the domestic hot water tank is not heated while in away scene.
The monitor menu allows you to view the following temperatures and running hours:
This menu provides advanced-level information.
Access
Change the access level on the thermostat.
Status Info
Displays the current status of the thermostat including any overrides from the tekmarNet® system control. Toggles between “Status Info” and the current status.
Software Version and Type Number
More Information
This User Brochure contains standard information on how to make adjustments to an installed product. More detailed information can be found in this product’s Installation and Operation Manual (552_D) at www.tekmarcontrols.com Product design, software, and literature are Copyright ©2014 by tekmar Control Systems Ltd., A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarControls.com All specifications are subject to change without notice
Download Manual:
tekmar 552_U Touchscreen Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…