Congratulations on the purchase of your tekmar programmable thermostat with communication. This thermostat combines easy-to-use programming with advanced features to increase both comfort and energy efficiency. Your tekmar thermostat allows you to :
The control uses a Liquid Crystal Display (LCD) as the method of supplying information on the operation of the thermostat.
Access Levels
This thermostat has five access levels:
This brochure only covers the features available in the SEC, LTD and USER levels. Only qualified service people should adjust the INST and ADV access levels.
Menu
All of the items displayed by the thermostat are organized into seven menus:
These menus are listed in the Menu Field on the top left hand side of the display.
Use the Menu button to advance to the next menu
Item
Each menu has several items. The abbreviated name of the selected item will be displayed in the item field of the display. To view the next available item, press and release the Item button.
Adjustment
To make an adjustment to a setting in the thermostat:
Default Item
When you display an item in the View menu for more than 5 seconds it becomes the default item. After you navigate other menus, the display reverts back to the default item after 60 seconds of button inactivity.
The Time is the only exception. It can be displayed indefinitely.
Use the View menu to view the current temperatures being sensed by the thermostat. To view the available temperatures, use the Menu button to go to the View menu. Use the Item button to view the temperatures.
The Room Set temperature is the temperature that the thermostat is currently set to maintain.
To view the Room Set temperature:
To adjust the Room Set temperature when there is no schedule in use:
If your thermostat is using a schedule, the current event of Wake, UnOcc, Occ, Sleep or Away displays on the screen.
To change the temperature for a schedule event:
If your thermostat is using a schedule and you would like to temporarily change the current heating temperature:
Adjusting the Temporary Zone Hold
You can adjust the length of the Temporary Zone Hold.
To adjust the length of the Temporary Zone Hold:
The thermostat has four modes of operation:
To choose the Mode of Operation:
If a floor sensor is installed, you can set the minimum floor temperature.
Caution: Setting a high floor minimum temperature can result in overheating the room.
To set the floor minimum temperature:
If a fan is connected to the thermostat, the fan on time can be adjusted:
To set the fan on time:
The thermostat keeps a record of the number of hours the fan runs. Once the number of hours exceeds the Filter time, a Filter symbol is displayed in the thermostat display.
To reset the Filter timer after you replace the filter:
Viewing the Current Time
To view the current time:
Use the Menu button to select the Time menu.
Scenes is a feature that your installer selects when he sets up each thermostat in your system.
Please refer to the Job Record J 545 for a record of how your installer made these settings
Scenes allow you to change the temperature of all the thermostats that use the Scene feature from a single thermostat.
Several of the Scenes are preset from the factory. However, your installer can customize several of the scenes based on your needs.
Refer to the Scene table below for a description of each scene.
Scene | Description | Thermostat Operation |
1 | Permanent 1 | Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away |
2 | Permanent Away 2 | Away DHW demands are ignored (applies to reset modules) Setpoint demands operate (applies to reset modules) |
3 | Permanent Unoccupied 3 | Unoccupied |
4 | Permanent 4 | Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away |
5 | Permanent 5 | Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away |
6 | Temporary Occupied 6 | Occupied for 3 hours |
7 | Temporary 7 | Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away for 4 hours |
8 | Temporary 8 | Scheduled event, Wake, Unoccupied, Occupied, Sleep, Away for 8 hours |
To select a scene:
Example:
A house is normally in scene Permanent 1. There is a master bedroom that operates on a schedule and there is a guest bedroom that is normally set to Unoccupied. When a guest arrives, the scene is to change to Permanent 4. Scene 4 changes the guest room to operate on the setback schedule.
Location | Scene | Temperature |
Master Bedroom | 1 | Schedule |
4 | Schedule | |
Guest Bedroom | 1 | UnOccupied |
4 | Schedule |
If you are going away for an extended period of time, the AWAYHOLD feature allows you to override the regular schedule of the thermostat for a set number of days. During the Away Hold, the thermostat operates at the Away temperature set by your installer.
After the Away Hold has expired, the thermostat returns to its normal operation.
If you have multiple tekmar thermostats installed, you need only to do the following on one thermostat.
To set the number of days you will be away:
To start the Away Hold:
Use the Monitor Menu to view the high and low temperatures sensed by your thermostat.
To view the temperatures:
During installation, your installer will have selected a schedule for your thermostat.
To view the schedule your installer has selected:
Schedule | Description |
None | No schedule is used. |
Zone | The schedule only applies to this thermostat. |
MST1, MST2, MST3, MST4 | This thermostat is a system schedule master. There are four possible system schedules. |
MBR1, MBR2, MBR3, MBR4 | This thermostat is a system schedule member. The number indicates which of the four system schedules the thermostat is following. |
Selecting the Schedule Type
The schedule type determines how frequently the schedule repeats itself. This thermostat includes four schedule types:
Schedule Type | ||||
Day | 24 Hour | 5-2 | 5-11 | 7 day |
Sa |
• | • | • | • |
Su | • | • | ||
Mo |
• |
• | • | |
Tu | • | |||
We | • | |||
Th | • | |||
Fr | • |
Selecting the Schedule Mode
The schedule allows for either 4 or 2 temperatures per day.
To select the schedule mode:
Setting the Schedule
The installer of this thermostat may have already entered
a schedule. Please refer to Job Record J545.
To set the schedule:
Schedule Mode | Event | 24Hr | Sat | Sun | Mon | Tue | Wed | Thu | Fri |
4 events per day | Wake | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM |
Unoccupied | 8:00 AM | 8:00 AM | 8:00 AM | 8:00 AM | 8:00 AM | 8:00 AM | 8:00 AM | 8:00 AM | |
Occupied | 6:00 PM | 6:00 PM | 6:00 PM | 6:00 PM | 6:00 PM | 6:00 PM | 6:00 PM | 6:00 PM | |
Sleep | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | |
or | |||||||||
2 events per day | Occupied | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM | 6:00 AM |
Unoccupied | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM | 10:00 PM |
You can display temperatures in either Fahrenheit (°F) or in Celsius (°C).
To change the units of temperature:
The thermostat’s display has a backlight. By default the backlight is temporarily On. You can also set the backlight to be either permanently On or permanently Off.
To change the backlight setting:
Clean the thermostat’s exterior using a damp cloth. Moisten the cloth with water and wring out prior to wiping the thermostat.
Do not use solvents or cleaning solutions.
When the thermostat encounters a problem, a Warning Symbol appears and a description of the error message is displayed. To troubleshoot how to correct the error, please refer to the Data Brochure or contact a qualified installer. An electronic version of the Data Brochure D 545 is available on the tekmar website: www.tekmarcontrols.com.
Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product (“Product”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same. The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s passthrough warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date. The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract. The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers.
Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser’s sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers.
The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar’s instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact information regarding the appropriate Representative.
tekmar Control Systems Ltd., Canada
tekmar Control Systems, Inc., U.S.A.
Head Office: 5100 Silver Star Road Vernon, B.C. Canada V1B 3K4
(250) 545-7749 Fax. (250) 545-0650
Web Site: www.tekmarcontrols.com
Product design, software and literature are Copyright © 2007 by:
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
All specifications are subject to change without notice.
Printed in Canada. U 545 – 08/07.
Download manuals:
Tekmar 545 Programmable Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…