CAUTION:
Installation Location
The thermostat should be mounted on an inner wall 1.5m above the floor in a position where it is readily affected by changes of general room temperature with freely circulating air. Prevent direct exposure to sunlight. Do not place this unit at a location where air circulation is low or where there is great temperature changes (e.g. near the door). Do not place the thermostat near any heat-generating sources (hot air vents, TV or lights).
Wiring
TheSMT-110 has 6 terminals at the back of the thermostat which are labeled as “C”, “Y” “G”, “RC”, “R” and “O/W B”. Different wirings are for different Mode types. “C” Terminal is optional for 24Vac Powered Mode type 1 (HO) : Two-wire Heat only
Start/Reset
Normal Display Mode
Temperature Setting Display Mode:
To adjust the Heat/ Cool setting
Internal Mode Setting Display:
To adjust the internal setting of SMT-110:
Model Type Selection
Function Setting Selection
Description of the Mode Types
Mode type | Function type | Setting | |||
HO | Heat only | HS | Span of Heater | 1°C / 2°F | |
2°C/ 4°F | |||||
dU | Temperature Display Unit | °C | |||
°F | |||||
HF |
Heat with fan | HS | Span of Heater | 1°C/ 2°F | |
2°C/ 4°F | |||||
dU | Temperature Display Unit | °C | |||
°F | |||||
FC | Fan Control Method | O | Gas Heater– equipment controls fan | ||
E | Electric furnace – thermostat controls fan | ||||
CL |
Cool | dU | Temperature Display Unit | °C | |
°F | |||||
CS | Span of Cool | 1°C/ 2°F | |||
2°C/ 4°F | |||||
Cd | Compressor Minimum-Off Delay | 1 | 1 minute compressor off delay | ||
2 | 2 minute compressor off delay | ||||
3 | 3 minute compressor off delay | ||||
4 | 4 minute compressor off delay | ||||
5 | 5 minute compressor off delay | ||||
HP |
Heat pump | HS | Span of Heater | 1°C/ 2°F | |
2°C/ 4°F | |||||
CO | Changeover Valve | C | O/B terminal energized in cooling (default) | ||
H | O/B terminal energized in heating | ||||
dU | Temperature Display Unit | °C | |||
°F | |||||
CS | Span of Cool | 1°C/ 2°F | |||
2°C/ 4°F | |||||
Cd | Compressor/ Heater Minimum-Off Delay | 1 | 1 minute compressor off delay | ||
2 | 2 minute compressor off delay | ||||
3 | 3 minute compressor off delay | ||||
4 | 4 minute compressor off delay | ||||
5 | 5 minute compressor off delay | ||||
SL | Mode Adjustment | 1 | Heat, Cool, Off Selectable | ||
2 | Auto, Off Selectable | ||||
3 | Heat, Cool, Off, Auto Selectable | ||||
HC |
Electrical /gas heat with cool (Default setting) | HS | Span of Heater | 1°C/ 2°F (Default setting) | |
2°C/ 4°F | |||||
dU | Temperature Display Unit | ° C (Default setting) | |||
°F | |||||
CS | Span of Cool | 1°C/ 2°F (Default setting) | |||
2°C/ 4°F | |||||
Cd |
Compressor Minimum-Off Delay | 1 | 1 minute compressor off delay | ||
2 | 2 minute compressor off delay | ||||
3 | 3 minute compressor off delay | ||||
4 | 4 minute compressor off delay (Default setting) | ||||
5 | 5 minute compressor off delay | ||||
SL | Mode Adjustment | 1 | Heat, Cool, Off Selectable | ||
2 | Auto, Off, Selectable | ||||
3 | Heat, Cool, Off, Auto Selectable (Default setting) | ||||
FC |
Fan Control Method | O | Gas furnace – equipment controls fan | ||
E | Electric furnace – thermostat controls fan (Default setting) |
Replaceable Batteries Instruction
Batteries shall be installed with proper polarity and correct battery type. Do not use old and new batteries simultaneously. Batteries shall be removed if consumed or if the product is to be left unused for a long time. Use 1.5V/ cell ALKALINE batteries 2 pieces.
Due to continual product improvement, these specifications are subject to change without notice.
Warranty – One Year Return to Base
Smart Temp Australia Pty Ltd
Unit 20, 1488 Ferntree Gully Road
Knoxfield Vic 3180
Tel (03) 9763 0094
www.thermostat.com.au
DOWNLOAD MANUALS:
Smarttemp SMT-110 Digital Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…