Flush-mounted room thermostat
Control of the room temperature in individual rooms of ventilation or air conditioning plants that are:
The RDU340 is suitable for use with VAV systems in connection with the VAV compact controller types G…B181.1E/3.
The RDU340 can also be used as an AHU temperature controller in connection with valve actuators, as well as for universal heating and cooling applications with DC 0…10 V actuators.
The RDU340 controls
Use in systems with:
Prior to snapping the front panel to the base, use the DIP switches on the inner side of the front panel to commission the thermostat’s applications and the behavior of the output signal.
Application and output signal, DIP switches, diagram
V1 Heating or heating/cooling valve actuator
B1 Return air temperature sensor or external room temperature sensor (optional)
E1 Electric heater
B2 Changeover sensor (optional)
Note
During startup, the thermostat reloads the control parameter factory settings after each DIP switch settings change
Product no. |
Operating voltage | Control output | Backlit LCD | Infrared receiver | Housing color | ||
3-pos | on/off | DC 0…10 V | |||||
RDU340 | AC 24 V | — | white |
DC 0…10 V actuator
Designation | Product no. | Data Sheet*) | |
Cable temperature sensor or changeover sensor, cable length 2.5 m NTC (3 kn at 25 °C) | QAH11.1 | 1840 | |
Room temperature sensor NTC (3 kn at 25 °C) | QAA32 | 1747 | |
Electrical actuator, DC 0…10 V (for radiator valve) | SSA61… | 4893 | |
Electrical actuator, DC 0…10 V (for 2- and 3-port valves / V…P45) | SSC61… | 4895 | |
Electrical actuator, DC 0…10 V (for small valve 2.5 mm) | SSP61… | 4864 | |
Electrical actuator, DC 0…10 V (for small valves 5.5 mm) | SSB61… | 4891 | |
Electrical actuator, DC 0…10 V (for CombiValves VPI45) | SSD61… | 4861 | |
Electromotoric actuator, DC 0…10 V (for valves 5.5 mm) | SQS65… | 4573 | |
Electrothermal actuator, AC 24 V, NC, DC 0…10 V, 2 m (for radiator valves and small valve 2.5 mm) | STA63 | 4884 | |
Electrothermal actuator, AC 24 V, NO, DC 0…10 V, 2 m (for radiator valves and small valve 2.5 mm) | STP63 | 4884 | |
DC 0…10 V damper / valve actuator | GQD161… | 4605 | |
GDB161… | 4634 | ||
GLB161… | |||
GMA161… | 4614 | ||
GEB161… | 4621 | ||
GCA161… | 4613 | ||
GBB161… |
4626 | ||
GIB161… |
VAV compact controller | GDB181.1E/3 | 3544 |
The documents can be downloaded from http://siemens.com/bt/download
Designation | Product no. | Data Sheet*) |
Changeover mounting kit (50 pcs/package) | ARG86.3 | N3009 |
Plastic mounting spacer for flush mounted thermostats for increasing the headroom in the conduit box by 10 mm | ARG70.3 | N3009 |
Conduit box for flush mounted thermostat | ARG71 / S55770-T137 | N3009 |
The documents can be downloaded from http://siemens.com/bt/download.
Ordering
When ordering, indicate both product number and designation: E.g. RDU340 room thermostat
Order valve actuators separately
Mechanical design
The thermostat consists of 2 parts:
The rear of the mounting base contains the screw terminals. The base fits on a square conduit box with 60.3 mm fixing centers. Slide the front panel in the mounting base and snap on.
Operation and settings
Mount the room thermostat on a recessed square conduit box with 60.3mm fixing centers. Do not mount on a wall in niches or bookshelves, behind curtains, above or near heat sources, or exposed to direct solar radiation. Mount about 1.5 m above the floor.
Mounting
Wiring
See the mounting instructions M3078 enclosed with the thermostat.
Warning!
No internal line protection for supply lines to external consumers (Y10, Y21)
Risk of fire and injury due to short-circuits!
Commissioning
Note
After powerfail the thermostat restarts in the same mode as before.
Control sequence
The control sequence may need to be set via parameter P01 depending on the application. The factory setting for the single duct application is “Cooling only”.
Calibrate sensor
Recalibrate the temperature sensor if the room temperature displayed on the thermostat does not match the room temperature measured (after min. 1 hour of operation). To do this, change parameter P05.
Setpoint and range limitation
We recommend to review the setpoints and setpoint ranges (parameters P08…P12) and change them as needed to achieve maximum comfort and save energy
Disposal
The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage.
Application:
Single duct in VAV/CAV Heating or cooling for universal or AHU
Application:
Single duct with electric heater in VAV/CAV Heating and cooling with electric heater for universal or AHU
Warning
Dimensions in mm
© Siemens Switzerland Ltd, 2008 – 2019
Technical specifications and availability are subject to change without notice.
Issued by
Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a CH-6300 Zug
Tel. +41 58 724 2424
www.siemens.com/buildingtechnologies
Siemens Smart Infrastructure
DOWNLOAD MANUALS:
SIEMENS RDU340 Flush-mount room thermostat Product Specifications Guide
SIEMENS RDU340 Flush-mount Room Thermostat Product Specifications Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…