RDE100.1DHW is a room thermostat that allows you to set the ideal room temperature at the time you want. In addition, it offers independent control of DHW. There are several switching patterns available that can be set to your specific needs.
Do you want to adjust the time and day?
You can set the current time of day.
set ok + – mode | Proceed as follows:
|
Do you want to lock the buttons?
mode | Press and hold mode for at least 7 seconds to activate a button lock. Repeat to unlock. The unit operates normally when the buttons are locked, but no changes are possible while the buttons are locked. |
Are your rooms too warm/too cold?
+ – ok set mode | Press + or – to increase or decrease the room temperature setpoint in increments of 0.5 °C / 1 °F. Proceed as follows:
|
Do you want to change the operating mode?
mode
! | The thermostat provides Comfort mode, Economy mode, and Auto mode. Changeover between the operating modes can be made manually by pressing mode. It is used during non-occupancy periods, for example at night. Note Frost protection is a function always active in the background. As soon the room temperature falls below 5 ºC, the unit automatically activates the heating |
Do you want to set permanent temperature setpoints?
set ok + – mode
! |
Note: This permanent setpoint is used during Auto timer mode. |
Do you want to set your Holiday mode?
set ok + – mode
! | Use the Holiday mode to set the thermostat to a constant temperature while absent.
Note: If you press mode while Holiday mode is active, the function is turned off and the If the Comfort and Economy setpoint values are both locked, the lowest locked setpoint value is the Holiday mode setpoint value. You can adjust the setpoint temperature from 5 ºC up to the lowest locked setpoint value. |
Option 1: Time switch with individual day selection (P11=0)
set ok + – mode
| You can select Comfort or Economy at 15 minute intervals throughout the day. The 0:00 to 24:00 hour time bar allows you to set the operating mode for the selected day(s). Example:
When Auto timer mode is enabled, changeover between the operating modes is automatic after the settings are saved. Proceed as follows:
|
Option 2: Time switch with the same 7 day selection (P11=1)
set ok + – mode
| You can set all the 7 day time switches at the same time. Example:
Proceed as follows:
|
Option 3: Time switch with 5-2 day selection (P11=2)
set ok + – mode
| You can set Monday – Friday time switch at once and Saturday – Sunday time switch at once. Example:
Proceed as follows:
|
Default value | Day/s | Comfort mode | Economy mode |
Mo (1) – Fr (5) | 6:00 – 8:00 hr 17:00 – 22:00 hr | 22:00 – 6:00 hr 8:00 – 17:00 hr | |
Sa (6) – Su (7) | 7:00 – 22:00 hr | 22:00 – 7:00 hr |
Do you want to activate DHW control?
DHW can also be switched on/off while frost protection |
Do you want to enter your own time switch for DHW control?
set ok | You can enter the DHW Auto Time switch as follows:
allows you to set DHW on or off for the selected day(s). Example:
There are 3 options for DHW Time switch setting: Individual day, 7 day and 5/2 day. To set the DHW Time switch, please follow the same steps as in the section “Do you want to enter your own time switch”. |
Default value | Day/s | DHW control ON | DHW control OFF |
Mo (1) – Fr (5) | 6:00 – 8:00 hr 17:00 – 22:00 hr | 22:00 – 6:00 hr 8:00 – 17:00 hr | |
Sa (6) – Su (7) | 7:00 – 22:00 hr | 22:00 – 7:00 hr |
Does symbol
Symbol
Do you want to change the parameters?
+ – ok mode | If you want to change control parameters, proceed as follows:
|
Parameter no. | Description | Setting range (default) |
P01 | Time format | 1 = 24:00 hours (default) 2 = 12:00 AM/PM |
P02 | Selection of °C or °F | 1 = °C (default) 2 = °F |
P03 | Standard temperature display | 1 = room temperature (default) 2 = setpoint |
P04 | Temperature sensor calibration | -3…3 °C Step 0.5 °C (-6…6 °F, step 1 °F) Default: 0 °C |
P06 | Comfort setpoint lock | 0 = OFF (default) 1 = ON à locked according to setting in permanent temperature setpoint |
P08 | Economy setpoint lock | 0 = OFF (default) 1 = ON à locked according to setting in permanent temperature setpoint |
P09 | Buzzer | 0 = OFF 1 = ON (default) |
P10 | Show frost protection icon | 0 = OFF (default) 1 = ON |
P11 | Time switch type for autotimer and DHW | 0 = individual Days (default) 1= all 7 days 2= 5/2 days |
P12 | Periodic pump run | 0 = OFF (default) 1 = ON |
P13 | DHW timer bar timeout | 0 = no DHW bar 1 = 1 minute (default) 2 = 2 minutes Adjustable range 0 to 15 minutes |
P21 | Button scanning rate for the capacitive buttons Note: a higher scanning rate means shorter battery life. | 0.2 = 0.25 s 0.5 = 0.5 s 1.0 = 1.0 s (default) 1.5 = 1.5 s |
P22 | Reload factory settings | 0 = OFF (default) 1 = reload |
P23 | Software version information | No adjustment possible |
P78 | Control behavior | 0 = On/Off, 1.0K 1 = On/Off, 0.3K 2 = TPI fast 3 = TPI medium 4 = TPI slow (default) |
P89 | Forward shift on max | 0, 0.5,…24 h Default: 0 h |
P90 | Early shutdown max | 0, 0.5,…6 h Default: 0 h |
DOWNLOAD MANUALS:
SIEMENS RDE100.1DHW Room thermostat Operating Manual
OTHER MANUALS:
SIEMENS RDE100.1DHW Room Thermostat Product Specifications Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…