SIEMENS

Siemens RDD100 Room Thermostat Operating Instruction

Siemens RDD100 Room Thermostat

RDD100.. – the room thermostat that allows you to set the ideal room temperature at the time you want.

Display

  • Indicating that batteries need to be replaced (only with battery-powered version)
  • Comfort mode
  • Economy mode
  • Frost protection (heating) is active
  • Display of room temperature, setpoint, etc.
  • Room temperature in degrees Fahrenheit
  • Room temperature in degrees Celsius
  • Button lock activated
  • Heating ON
  • Current room temperature
  • Change operating mode
  • Decrease value
  • Increase value
  • Battery holder

Do you want to change the operating mode?

  • The thermostat provides Comfort mode , Economy mode . Changeover between the operating modes can be made manually by pressing .
  • Comfort mode is the permanent (24 h) selection of Comfort. Select this mode to maintain Comfort temperature permanently. It is used during occupancy periods, for example.
  • Economy mode is the permanent (24 h) selection of Economy. Select this mode to maintain the Economy temperature permanently. It is used during non-occupancy periods, for example at night.
  • Note: Frost protection is a function always active in the background. As soon the room temperature falls below 5 ºC, the unit automatically activates the heating .

Energy saving tips without sacrificing comfort

  • Use Economy mode for long periods of non-occupancy

Do you want to lock the buttons?

  • Press and hold for at least 7 seconds to activate a button lock. Repeat to unlock.
  • The unit operates normally when the buttons are locked, but no changes are possible while the buttons are locked.

Are your rooms too warm/too cold?

  • +/- Press + or – to increase or decrease the room temperature setpoint in increments of 0.5 °C /
  • 1 °F. Proceed as follows:
    • Press + or – to adjust the setpoint temporarily. Press to save the value or wait for the program to exit automatically.
    • To permanently modify the temperature setpoints, use parameters P05 and P07. To lock the setpoints, use parameters P06 and P08.

Does symbol appear on the display? (Only with battery-powered version)
Symbol is displayed when the batteries are low. Replace them with 2 new alkaline batteries type AAA. Proceed as follows:

  • Get 2 new alkaline batteries type AAA
  • Remove the battery holder, then the batteries, insert the new batteries and, within 1.5 minutes, replace the battery holder
  • Ensure the exhausted batteries are disposed of correctly, in compliance with environmental requirements

Do you want to change the parameters?

  • +/- If you want to change control parameters, proceed as follows:
    • Press + and – simultaneously for 5 seconds
    • Release them and parameter “P02” is displayed
    • Press + or to scroll to the parameter that needs to be adjusted
    • Press to select this parameter
    • Press + or to adjust the value
    • Press to confirm and save the adjusted value
    • Select and modify other parameters
    • The program automatically returns to the normal screen after a timeout.

Parameter list

Parameter no. Description Setting range (default)
P02 Selection of °C or °F 1 = °C (default)
2 = °F
P03 Standard temperature display 1 = room temperature (default)
2 = setpoint
P04 Temperature sensor calibration -3…3 °C Step 0.5 °C
(-6…6 °F, step 1 °F) Default: 0 °C
P05 Comfort setpoint 5…35 °C, step 0.5 °C (41…95 °F,  step 1 °F)
Default: 20 °C,  68 °F
P06 Comfort setpoint lock 0 = OFF (default)
1 = ON è locked according to setting in P05
P07 Economy setpoint 5…35 °C, step 0.5 °C (41…95 °F,  step 1 °F)
Default: 16 °C,  61 °F
P08 Economy setpoint lock 0 = OFF (default)
1 = ON è locked according to setting in P07
P09 Buzzer 0 = OFF
1 = ON (default)
P10 Show frost protection icon 0 = OFF (default)
1 = ON
P21 Button scanning rate for the capacitive buttons (touch keys, RDD100.1 only)
Note: a shorter scanning rate means shorter battery life.
0.2 = 0.25 s
0.5 = 0.5 s
1.0 = 1.0 s (default) 1.5 = 1.5 s
P22 Reload factory settings 0 = OFF (default)
1 = Reload
P23 Software version information No adjustment possible

REFERENCE:

DOWNLOAD MANUALS:

Siemens RDD100 Room thermostat Operating Instruction

OTHER MANUALS:

Siemens RDD100 Room Thermostat Product Specifications Guide

Siemens RDD100 Room Thermostat Operating Instruction

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago