ST2 is a powerful and efficient modular room thermostat with exchangeable modules. It can be used in heating or (and) cooling systems. It is suitable for radiator, convector and surface heating systems. This manual applies for:
LEGEND
1 this option is not available in all ST2 editions
Heating activation
Press the key
Room heating operates according to the program timer CH1, domestic hot water warming operates according to the program timer CH2.
Stand-by
Press the key
Frost protection remains active
The frost protection temperature is 6 °C and can be changed in program group P1.3 (page 26).
Day temperature
Turn the knob to set the requested day temperature between 10 °C and 30 °C (Picture 4).
Night temperature
Hold a key
Hold the key
Room heating with the comfort temp. operates according to the program timer CH3 and has precedence over to room heating according to the program timer CH1.
If the comfort heating mode is inactive, the comfort temperature setting is also inactive. The comfort temperature mode is set in program group P1.8 (page 26).
PARTY – day temperature operation
Press key
ECO – night temperature operation
Press key
The ECO temperature reduction is set in program group P1.2 (page 26).
Hold the key
To stop HOLIDAY mode at any time, again hold the key
The HOLIDAY mode temperature is set in program group P1.4 (page 26). Factory pre-setted HOLIDAY temperature is 12 °C.
If the ST2, by battery exchange, isn’t functional for a while, the time is set to Monday, 20:00.
Selecting the program channel
Hold the key
Modifying the time program
Press key
Now press key
Every channel in the program timer (CH1, CH2 and CH3) has 32 program spaces. Time commands for day and night temperature mode, time commands for active and inactive d. h. w. warming and time commands for active and inactive comfort temp. mode are successively followed.
Unused time commands are indicated as – -:- – (picture 15). Room thermostat ST2 displays only used program spaces.
Room thermostat ST2 has 6 pre-setted time programs for room heating and 6 pre-setted time programs for domestic hot water warming. For each channel CH1 and CH2 is possible to select between 4 fixed (Pr1, Pr2, Pr3, and Pr4) and 2 users set time programs (Pr1 and Pr2 ).
Pre-setted time program selection
Hold the key
The selected time program always overwrites the previous one. To keep the current time program active, select – – -.
Table 1: Pre-setted time programs Pr1, Pr2, Pr3, Pr4
In the program timer, CH1 and CH2 are factory pre-stored time programs Pr1
User-pre-setted programs Pr1
Pre-setted time programs with a symbol
By default is in program Pr1
In order to protect against legionaries disease, this room unit has a special function that warms the d. h. w. over 63 °C.
The function is activated with a five-minute ON interval in the program timer (CH2).
Example :
Day | ON | OFF |
Mo-Fr | 6:00 | 8:30 |
Mo-Fr | 11:00 | 13:30 |
Mo-Fr | 16:00 | 22:00 |
Fr | 5:00 | 5:05 |
Sa-So | 6:00 | 20:00 |
The ST2 will warm the d. h. w. over 63 °C every Friday at 5 a. m.. If no d. h .w. temperature sensor is connected to the room there-most will warm the d. h. w. for 2 hours.
We suggest you, to run the anti-legionaries program once in a week during the nighttime.
Manual d. h. w. warming activation
Hold key
Manual domestic hot warming is automatically deactivated when requested d. h. w. temperature is reached or at the latest after 1 hour.
Thermostat locking
Hold the key
Setting or modifying the parameters by locked ST2 isn’t possible or it’s limited.
ST2 locking is set in service group S1.9 (page 29).
Selection between heating or cooling
To switch over between heating and cooling and in reverse, hold the key
With the telephone is possible to remotely activate the day temperature mode. Remote activation is signalized with the symbol
Auxiliary temperature sensor – temperature overview
The temperature of the additional temperature sensor is displayed if in the normal display mode the command “Escape˝ is applied, . Only if the additional temperature sensor is connected.
Command to quickly save and quit (Escape)
Every time you wish to quick store and quit set-up, hold the key
All modifications made, are stored. This command isn’t valid for program and service settings.
Empty batteries are indicated with the symbol
Battery exchange should be done within 20 seconds. In another case you will have to set the accurate time again.
All data and settings are joined into 16 groups:
Menu
To enter the menu, hold the key
Menu navigation
In the menu, keys have new meanings, marked below them (Picture 21). To move between the groups press key
Group locking is setted in Service group S3 (page 30).
Room thermostat data d1
This group is sort of ST2. ID. In this group are information about ST2, modifying isn’t possible. The information are displayed in the following order:
Program group P1
Program group P1 is used for the thermostat user settings. To change the selected parameter, hold key
This procedure, for modifying the parameter, is the same for all program and service groups
Group P1 contains the following parameters; (factory setting):
1 Activation is every Saturday at:
Program group P2
In program group P2 are the following parameters; (factory setting):
Program group P3
In program group P3 are the following parameters; (factory setting):
Service group S1
Service group S1 is intended for thermostat service settings. In program group S1 are the following parameters; (factory setting):
1 Heating optimization: ST2 automatically calculates the switch-on time and at set time (night-day changeover) the requested temperature is already reached.
Service group S2
Service group S2 is intended for additional thermostat service settings. In program group S2 are the following parameters; (Factory setting):
Service group S3
Service group S3 is intended for special thermostat settings.
In program group S3 are the following parameters:
Access to parameter S3.1 is possible in the following way. Hold key for 20 seconds (picture 24). Release the key after you hear a beep. On the display appears parameter (S3.1). Now it’s possible to modify this or any other parameter.
1 Parameter S2.8, S2.9, and S2.10 are intended only for heating circuits with 3-point control
Radio connection – test mode for ST2TX
Check if your receiver has the same radio channel number as settled in parameter S2.8 on ST2TX. Now activate test mode. Hold key and press and hold the key for 5 seconds (picture 25). Release the keys after you hear a beep.
Signal power indication by receivers RX22, versions up to V1.9
If the radio connection is established, R1 is activated and deactivated every 2 seconds. Receiver every 10 seconds lowers the reception intention, which is signalized with the light R2. Radio connection will operate without interceptions if R1 is activated and deactivated also by lowered signal intensity.
Signal power indication by receivers RX22, version V2.0 or higher
If the radio connection is established, R1 is activated and deactivated every 2 seconds. Signal light R2 indicates the signal intensity with flashing. Signal intensity is indicated with 1 to 5 flashes. The radio connection will operate without interruptions if the light R2 flashes at least 2 times.
Test mode automatically expires after 5 minutes. You can also end it by using the command ”Escape”.
To restore the factory settings hold keys
Table 2: Possible applications for particular modules
The place of the mount is very important for proper ST2 operation. Suitable places are inner walls, which aren’t sun lighted or exposed to sources of heat and wind. ST2 should be mounted approximately 150 cm above the floor (Picture 27).
Wall plate mount
Remove the ST2 from the wall plate, by doing the following. With one hand hold ST2 in the height of the keys and with the other hand the wall plate. Now pull them apart (Picture 28).
Unscrew and temporarily remove the protection cover (Picture 29). The room thermostat is intended for wall mounting. In case you don’t have installed a flush box, tear away the drilling template from the package and mark drilling holes. Use enclosed screws to fasten the wall plate on the wall (Picture 30). After you have done connecting the wires (see chapter Connecting the wires), screw back the protection cover. Now put ST2 back onto the base by doing the following. Hook ST2 on top of the wall plate and push it with the bottom towards the wall plate (Picture 19- CLOSE).
WARNING: Mounting and wiring connections must be done by a qualified installer or authorized company. Local regulations or VDE 0100 and EN IEC 60364 regulations for electrical installations must be considered by doing the wiring connections.
Bring the wires through the opening in the bottom of the wall plate (Picture 30-position A). How to connect the module is detailed and described on pages 115 to 133.
Connecting the auxiliary temperature sensor
Always connect the auxiliary tem-perature sensor into the connector terminals a and b on the wall ST2 plate (Picture 45). Set the parameters for this sensor in service group S1.
Sensor malfunction
If auxiliary temp. the sensor is in a short circuit, the display writes out
If the auxiliary sensor is disconnected, the display writes out
ST2R – ST2 with relay module R
With a room thermostat ST2 is possible to control:
The table on page 115 shows parameter S1.1 settings for thermostat ST2R.
ST2RDR – ST2 with double relay module RDR
With a room thermostat, ST2RDR is possible to control:
The table on page 122 shows parameter S1.1 settings for thermo-stat ST2RDR.
ST2TX – ST2 with relay module R with module for wireless control TX
ST2JV – ST2 with module for gas boilers JV
With a room thermostat, ST2JV is possible to control:
The table on page 128 shows parameter S1.1 settings for thermostat ST2JV.
ST2JVDR – ST2 with module for gas boilers JV and auxiliary relay module DR
With ST2JVDR is possible to control:
Room thermostats ST2 meet the requirements and rules of the following directives:
PRODUCT DESCRIPTION:
Room thermostat
MODEL:
ST2R, ST2RDR, ST2TX, ST2JV, ST2JVDR
APPLIED STANDARDS:
Disposal of Old Electrical & Electronic Equipment
Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help preventpotential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
Type | Description | S1.1 |
ST2R | Boiler control (picture 31) | 1 |
ST2R | Direct heating circuit pump (picture 32) | 1 |
ST2R | Heating circuit with mixing valve (picture 33) | 1 |
ST2R | Gas boiler (picture 34) | 1 |
ST2R | Electric floor heating (picture 35) | 5 |
ST2R | Domestic hot water warming (picture 36) | 6 |
ST2R default setting for parameter S1.1=1.
Boiler Control
Direct heating circuit pump
Heating circuit with mixing valve
Gas Boiler
Electric floor heating
Domestic hot water warming
Type | Description | S1.1 |
ST2RDR | Direct heating circuit (picture 37) | 1 |
ST2RDR | Direct heating circuit and domestic hot water warming (picture 38) | 2 |
ST2RDR | Indirect heating circuit – 3-point control (picture 39) | 3 |
ST2RDR | Direct heating circuit and boiler with built in domestic hot water storage tank 1 (picture 40) |
4 |
ST2RDR | D. h. w. warming (picture 41) | 6 |
ST2RDR | Direct heating circuit and cooling (picture 42) | 9 |
ST2RDR default setting for parameter S1.1=2.
1 Boiler is activated when there is need for domestic hot water.
Direct heating circuit
Direct heating circuit and domestic hot water warming
Indirect heating circuit – 3 point control
Direct heating circuit and boiler with built in domestic hot water storage tank
D. h. w. warming
Type | Description | S1.1 |
ST2JV | Gas boiler Junkers (picture 41) | 7 |
ST2JV | Gas boiler Vaillant (picture 42) | 7 |
ST2JV default setting for parameter S1.1=7.
Gas boiler Junkers
Type | Description | S1.1 |
ST2JVDR | Gas boiler Junkers and domestic hot water circulation (picture 44) | 8 |
ST2JVDR | Gas boiler Vaillant and domestic hot water circulation (picture 45)
| 8 |
ST2JV default setting for parameter S1.1=7.
D. h. w. warming
Gas boiler Junkers
We reserve the right for changes and improvements
Download Manual:
Seltron ST2 Digital Room Thermostats USER MANUALS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…