Seltron

Seltron ST1B Digital Room Thermostats Technical Data Sheet

Seltron ST1B Digital Room Thermostats

Presentation

ST is the new generation of modern room thermostats. They are used for the control of room temperature in smaller houses or for the zone control of room temperature in larger residential facilities. In addition to the room temperature, it also measures the relative air humidity and pressure.

Typical application

  • Radiator or convector heating.
  • Floor heating (low-temperature control of the supply temperature must be ensured).
  • Wall or ceiling heating or cooling.
  • Electric floor heating.

Features

  • Up to 5 preset applications.
  • 2 preset time programmes.
  • Simple use and setup.
  • Display of the measured and desired temperature.
  • PARTY, ECO and HOLIDAY user functions.
  • Weekly program timer for time programmes.
  • Automatic switchover between winter and summer time.
  • No new setup required in the event of power failure.
  • Measurement of relative air humidity, air pressure, weather forecast display.
  • Simple installation and connection.

Description of settings buttons

  1. Illuminated LCD display.
  2. Increasing, move forwards.
  3. Overview of information displays.
  4. Light sensor.
  5. Change in operation mode, Escape.
  6. Reducing, move backwards.
  7. PARTY function switch on/off.
  8. ECO function switch on/off.
  9. HOLIDAY function switch on.

Technical Data Sheet

Typical application ST1B ST1N ST1E
Battery-powered
Mains power supply
Heating or cooling control of residential rooms
Heating or cooling control of business premises
Technical characteristics
No. of mechanical relays 1 1 1
No. of temperature sensor inputs 1 1 1
System control
Radiator or convector heating
* Floor heating or cooling
* Wall or ceiling heating or cooling
Electric floor heating
* Low-temperature control of the supply temperature must be ensured
Heating circuits control
Direct heating circuit
Mixing heating circuit
Heat source control
Flow boilers
Liquid or solid fuel boiler
User functions
Room heating or cooling
PARTY function – activation of the comfort operation mode
ECO function – low-energy temperature activation
HOLIDAY function – holiday energy-saving mode
Heating system protection
Room frost protection
Limiting the maximum screed temperature or wall heating
Setup and installation
Possibility of wall installation
Possibility of installation into a flush-mounted box
Simple installation and connection

Outlined functions

Large backlit display
The ST room thermostats feature a large display that allows the users to read the information from a distance. The ST model is equipped with a light sensor for an optimum visibility, with the help of which the illumination of the display is adapted to the light in the room.

Preset time programmes
ST room thermostats provide the selection between two preset time programmes. The user is able to create the time programmes according to their wishes, or they may use to preset time programmes and adapt them if necessary.

PARTY, ECO, HOLIDAY user functions
The thermostat is equipped with quick buttons through which we enter user functions directly, such as PARTY , ECO and HOLIDAY. By choosing the PARTY function, the daytime room heating is prolonged.
By choosing the ECO function, the heating temperature reduces for a certain period of time.
In the holiday operation mode, we set the heating temperature during our prolonged absence.

Measurement of relative air humidity, air pressure, weather forecast display
ST measures the air humidity and pressure in the room. Based on the air pressure, also the weather forecast is possible.

Installation options
Battery powered room thermostats or thermostats with a standard electrical connection are available. They can be installed into a pre-prepared flush mounted socket or on the wall.

Technical specifications                                                ST1B                        ST1N                       ST1E
Backlit LCD display
Weekly program timer
Power supply 2 × AAA (1.5 V) 230 V/50 Hz 230 V/50 Hz
Own consumption 0.1 mW 0.2 W 0.2 W
Clock power supply CR1025 battery (Li-Mn) 3 V
Time display hours:minutes (24-hour)
Clock accuracy +/-1 s (24 h) at 20 °C
Degree of protection IP30 according to SIST EN 60529
Safety class according to SIST EN 60730-1 II
Type of temperature sensors Murata NTC (10 kohm)
Housing material PC + ABS
Operating temperature 0÷40 °C
Storage temperature -20÷65 °C
Product weight 220 g 140 g 177 g
No. of pieces in the packaging unit 24 pcs

Dimensions

Electrical connection

Applications for ST1B and ST1N

Applications for ST1E

Seltron d.o.o.
Tržaška cesta 85 A
SI-2000 Maribor
Slovenia
T: +386 (0)2 671 96 00
F: +386 (0)2 671 96 66
sales@seltron.eu
www.seltron.eu

Reference

DOWNLOAD MANUAL:

Seltron ST1B Digital Room Thermostats Technical Data Sheet

Seltron ST1B Digital Room Thermostats Technical Data Sheet

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago