Environmental | ||
Temperature | 32 to 104 F (0 TO 40 C) | |
Humidity | 10% to 90% (non-condensing) | |
Standards | ||
Wireless | Wi-Fi (802.11 b/g/n 2.4 GHz) IMPORTANT! 802.11r fast roaming is not supported. | |
Security | 70 mA typical, 250 mA maximum | |
Max Power | 6 watts | |
Power | ||
Input | 24V AC | |
Current Draw | 70 mA typical, 250 mA maximum | |
Max Power | 6 watts | |
Cable Requirements | ||
Power | #18 AWG | |
HVAC | #18 AWG Thermostat Wire (solid) | |
Remote Sensors | #24 AWG – 500 feet (152 m) max | |
Regulatory | ||
Safety / Emissions | FCC Part 15 | |
FCC ID: | ASU-CLIW200 | |
IC: | 10052A-CLIW200 | |
RoHs | Compliant |
Welcome
This document describes how to:
The following is needed for a trouble free installation:
CAUTION! When replacing an older thermostat that contains Mercury in a sealed tube, do not discard into trash. Refer to the thermostat-recycle.org website for information on how to properly dispose.
Location and Mounting Overview
For new installations or when relocating the thermostat, follow the guidelines below:
Remove Old Thermostat
When connecting wires to the CLI-W200, follow the guide-lines set below to ensure a safe and secure connection.
Connecting Power
The CLI-W200 does not run on batteries and requires a separate power source to operate. To power the thermostat, a voltage must be applied to the RH and 24C terminals. If only the power wires removed were from the R and C terminals of the old thermostat (See Remove Old Thermostat section above), use the diagram below to make connections.
Additional Powering Schemes
If the HVAC system uses separate power sources to run the heating and cooling, you should have three wires labeled for power (R, C, and RC). In this scenario, remove the jumper shunt from JP1. The next section describes this.
Jumper Shunt – JP1
Jumper JP1 on the thermostat board connects the RH and RC terminals. The thermostat is shipped from the factory with a jumper shunt installed. For systems with more than one power source, remove the jumper shunt.
Use the table below to connect the signaling wires from the HVAC system. Depending on the type of system installed in your home will determine which wires are connected. In some installations, only the power wires described in the previous sections are required.
TIP: Refer to the Making Connections section above to ensure a safe and secure connection is made.
Temperature Sensors
There are connections for two temperature sensors.
Smart Sensor Connection
A 1-wire humidity/temperature (CLI-THFM1) sensor that sup-ports measuring both humidity and temperature can also be added to the system. Connect the sensor to the 1-Wire, 5V DC, and GND terminals as shown in diagram below.
Network and Configuration Requirements
With the thermostat installed and wired, it can now be added to the local network and once communicating with the Savant Pro System Host an HVAC configuration can be created and uploaded to the Host. Locate the CLI-W200 Thermostat De-ployment Guide available on the Savant Customer Communi-ty to finish installation of the thermostat.
Network Configuration
To ensure the IP Address will not change due to a power outage, Savant recommends DHCP reservation be configured. Using this method, static IP Addresses for all devices can be managed from a single User Interface, avoiding the need to access devices individually. Setting DHCP reservation varies from router to router. Refer to the documentation for the router to configure DHCP reservation.
Additional Information
Does the CLI-W200 require batteries?
No, the CLI-W200 is powered using the power from the HVAC system. If no common (C) wire was removed from the old thermostat, a common wire must be added.
How does CLI-W200 get software updates?
Software is updated Over The Air (OTA). Whenever an update is available on the Savant Cloud, the update will take place automatically. The CLI-W200 must be connected to a local network that has WAN access for the updates to occur.
Will CLI-W200 still work if the Wi-Fi connection is lost?Yes, most thermostat functions will still function when not connected to Wi-Fi. However, functions such as schedules and OTA updates can not occur.
My thermostat was received damaged. What should I do?
If the thermostat was purchased through a contractor or retailer, contact the contractor or retailer to return it. If ther-mostat was purchased from the Savant Store, contact Savant through the Savant Customer Community.
Are both Fahrenheit and Celsius supported?
Yes
Does the thermostat support measuring humidity?
Yes, Savant offers a 1-wire smart sensor (CLI-THFM1) that measures both humidity and temperature.
Does the thermostat support setting both a heating and cooling set point?
No, The CLI-W200 thermostat is a single set point thermo-stat. However, the thermostat does support adding a +/- range to the set point. For example, adjusting the set point to 70° with a range of +/- 3° will manage the temperature so it stays between 67° and 73°.
Regulatory
The following statements are applicable to the CLI-W200x
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equip-ment off and on, the user is encouraged to try correct the interference by one or more of the following measures:
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
FCC and IC Identifier for Savant Thermostat
This device electronically displays the FCC declaration of conformity logo as well as the FCC and IC identifier. This information can be found on the device by accessing:
HVAC Mode menu
Industry Canada Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operate with minimum distance 20cm between the radiator and your body.
© 2018 Savant Systems, LLC,
For product information
Address: 45 Perseverance Way, Hyannis Ma. 02601
Telephone: 508.683.2500
Savant.com
04/13/2018
Download Manual:
Savant CLI-W200 Smart Thermostat QUICK START GUIDE
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…