Here’s what you will see on the home screen:
Here’s what you will see on the home screen:
System mode
Shows your current setting:
(heat/cool/auto/off/aux)
Humidity
Shows the indoor humidity in your home.
Indoor temperature
Shows the indoor temperature in your home. Click to slide up or down to adjust preferred temperature.
Menu
Allows you to control your system, schedule a vacation, and more.
Voice control
Allows you to enable / disable microphone.
Status
Ventilator/dehumidifies / humidifies
Quick changes
Touch this button to easily Check the time, set the current mode, adjust the brightness/sound,switch between home and away.
Alerts and reminders
The alarm sign will appear if the temperature or humidity exceeds the designed limit.
Five-core lead length 500mm (18#AWG) input: R,C,G,Y,G
Two ways to install thermostat
STEP1
Power off your Heating , Ventilation , and Air Conditioning(HVAC) system by using the master switch or circuit breaker box. This is important for your safety.
STEP2
Confirm your system is off by turning on your heat(during winter)or your AC(during summer).Wait a few minutes-you should not feel air coming from your vents.
STEP3
Remove your old thermostat cover from the wall.
TIPS:
CHECKPOINT: COMPATIBILITY
Does your old thermostat’s backplate have any of these indicators?
STEP4
Take a picture of the wires connected to the terminals of your old thermostat. you may need to reference this photo later on.
CHECKPOINT: C WIRE
Do your have a C wire connected to you old thermostat ?
TIPS: The wiring on your old thermostat may look different, just check to see if there’s a C wire.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
If you have a C wire, it will power your thermostat. you won’t need the Electric Control Module included in the box.
TIPS:
TO install accessories(humidifier,dehumidifier or ventilator)please refer to the wiring diagrams at wiring.
STEP5
Carefully disconnect and label the wires from your old thermostat one at a time, using the labels provided.
TIPS: If you have a jumper between RC, RH, OR R, leave it alone. Only label the wires that run from your wall into a terminal block.
STEP6
Unscrew the mounting plate of your old thermostat to remove it from the wall.
WARNING: Be careful, as some thermostat may contain mercury.
Recycle your old thermostat safely with your local hazardous waste facility.
STEP7
Decide if you want to use the Base platewith your thermostat.
The Base plateis useful if you want to hide marks or holes left on the wall by your old thermostat.
If using the Base plate,align the mounting holes on the Base plateand backplate and press them into place together.
STEP8
Pull the wires through the hole in the middle of the backplate and then attach the backplate to the wall using the drywall anchors and screws provided.
TIPS: Use a 3/16” drill a hole for the drywall anchors.
CHECKPOINT: INSERT YOUR R WIRE(S)
Do your have more than one R wire?(That includes R,RC,and RH)
STEP9
Insert your remaining wires into the side (not the front) of their corresponding terminal blocks.
STEP10
Tug on the wire gently to ensure they are securely connected.
TIPS:
STEP11
Gently press your thermostat into the backplate until it “clicks” into place.
TIPS: If the thermostat “rocks”or is not flush with the wall,be sure the excess wires are pushed all the way into the wall.
STEP12
Turn the power to your HVAC system back on using the master switch or at the circuit breaker box.
Congratulations, you did it!
Say hi to your new thermostat! To complete your setup and registrations, follow the instructions on your thermostat screen.
Install your thermostat without a C wire
If you don’t have a C wire, you will need to use the Electric Control Module included to reliable power your thermostat.
CHECKPOINT: 3 OR 4 WIRES
The Electric Control Module requires your system to have either of the following:4 wires W1, Y1,G, and R(or RC or RH)
Do you have these wires?
STEP5
Take your Electric Control Module, wire labels, tools, and your smartphone, and go to your HVAC system.
STEP6
Open your HAVC system’s cover to reveal at the control board.
STEP7
Take a picture of the wires connected to your control board. You may need to reference this photo later on.
WARNING: HVAC system contain high voltage wires. Use caution when working with the control board. If you’d rather leave it up to a professional.
STEP8
Label only the R, Y, or Y1, G, and W or W1 wires with the matching labels provided. If you have more than one wire going into these terminals, only label those going to your thermostat.
STEP9
Disconnect the wires labeled R,Y,G,and W from the control board.
Important Attention please,at this time, you need to change the wire number. As follow:
STEP10
Connect the wires you disconnected from the control board into their matching green terminal blocks on the Electric Control Module.
STEP11
Tug on the wires gently to ensure they are securely connected.
TIPS:
STEP12
Connect the five wires coming out of your Electric Control Module to their corresponding terminals on the control board.
CHECKPOINT: Electric Control Module
Check that you have installed the Electric Control Module correctly. It should be installed between your thermostat wiring and your control board.
STEP13
Mount the Electric Control Module inside your HAVC system, taking care not to strain the wires. Close the HVAC cover panel securely return to your thermostat.
TIPS: Make sure your HVAC panel is fully closed. Some systems will not turn on if the cover panel has not been closed properly.
STEP14 Back at your thermostat:
Carefully disconnect and label the wires from your old thermostat one at a time, using the labels provided. If you have a jumper between RC, RH, or R leave it alone. Only label the wires that run from your wall into a terminal block.
Important: Attention please,at this time, you need to change the wire number. As follow:
Take a phone before disconnecting the wires from your old thermostat , You may need to reference this photo later on.
Take a phone before disconnecting the wires from your old thermostat ,You may need to reference this photo later on.
STEP15
Unscrew the mounting plate of your old thermostat to remove it from the wall.
WARNING: Be careful, as some thermostats may contain mercury. Recycle your old thermostat safely with your local hazardous waste facility.
STEP16
Decide if you want to use the Base plate with your thermostat. The Base plate is useful if you want to hide marks or holes left on the wall by your old thermostat.
If using the Base plate, align the mounting holes on the Base plate and backplate and press them into place together.
STEP17
Pull the wires through the hole in the middle of the backplate and then attach it to the wall using the drywall anchors and screws provided.
TIPS: Use a 3/16” drill a hole for the drywall anchors.
STEP18
First, connect these 4 wires as show: RC,C,S,W1. Then connect any remaining wires to their corresponding terminal.
TIPS:
Press the terminal block levers to insert the wires more easily.
CHECKPOINT: DON’T SKIP AHEAD
Did you connect the correct wires to the RC,C,S,W1 terminals, as shown below?
STEP20
Tug on the wire gently to ensure they are securely connected.
STEP20
Gently press your thermostat into the backplate until it “clicks” into place.
TIPS: If the thermostat “rocks”or is not flush with the wall, be sure the excess wires are pushed all the way into the wall.
STEP21
Turn the power to your HVAC system back on using the master switch or at the circuit breaker box.
Wiring must comply with applicable codes, ordinances and regulations.
SASWELL NTC 100K Room Sensor With 3 Meter Wiring
Used for outdoor temperature detection when there is water pump protection.
SASWELL Wireless Room Sensor
Used for detecting human activities.(refer to PIR sensor manual)
Boiler or radiant system with air handler and conventional cooling or heat pump.
Accessory devices
The T18 can control an accessory HVAV device like a humidifier, dehumidifier, or ventilation device from its AC terminals.
Note:You will need to configure the accessory device when you first power on your T18.
2-wire accessory (humidifier/dehumidifier/ventilator)
1-wire accesory
(humidifier/dehumidifier/ventilator)
T18 automatically connects Rc to AC- when 1-wire configuration is selected during accessory setup.
Warning: Damage may occur if accessory is connected to AC
1-wire Integrated dehumidifier
T18 automatically connects RC to AC- when 1-wire configuration is selected during accessory setup.
Warning: Damage may occur if accessory is connected to AC
HRV/ERV
Note: To determine which wires from your ERV/HRV need to be connected to the AC+/AC- terminal on your T18, You need follow the product prompts to choose 1-wire or 2-wire.
Congratulations, you did it!
Say hi to your new thermostat! To complete your setup and registrations, follow the instructions on your thermostat screen.
Items needed for Wi-Fi connection:
How do I connect Alexa and WiFi ?
Please refer to the following steps at T18 that will help you.
T18: “MEUN” > “USER SETTINGS” > “START CONNECT WIFI” > “OK”
If login alexa failed,try to click“Login With Alexa” or “skip login with alexa”.
Set the bedroom(Device name) to Cool/heat/auto/aux/off mode
You can say “change/switch/turn/make bedroom to cool mode”
You can say such as follow:
Download manual:
Saswell T18UTK-7 WIFI Smart Thermostats Installational Manual
Saswell T18UTK-7 WIFI Smart Thermostats Installational Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…