Copying of this user manual without the permission of Sen Controls
Next to the thermostat is a separate receiver (switch unit) Saswell SAS2010DE with which wireless communication is performed (868MHz). Both devices are part of the sales package SAS908XWHB-7-RF (SL1). The receiver manages the connection function and system switching, and the thermostat enables the temperature control and setting. The system provides wireless, simple, and comfortable use of your heating system. The system also allows the setting of the heating schedule program for 7, 5 + 2, 5 + 1 + 1 days, and 4 oz. 6 switches per day. The SAS908XWHB-7-RF (SL1) system can also be used with a combination of ON / OFF thermostat actuators. The kit is designed for indoor use. The device is of type “class 2”. As extra functions, the thermostat has the option to lock the keypad with a user set 4 number code and an automatic open window detection, which stops the heating to prevent energy loss, and an option to set the thermostat’s temperature refresh rate in seconds. The instructions for use and maintenance are part of the general terms and conditions of sale. We reserve the right to change the details, technology, and performance. The guarantee is valid only with the original invoice. We allow the possibility of errors in the text. The warranty and warranty statement is located at the end of this manual.
Environmental Protection
Do not place electronic products and batteries after the end of their life in mixed municipal waste, use collection points of separate waste. By properly removing the product, you will prevent negative effects on human health and the environment. Recycling of materials contributes to the protection of natural resources. More information on the recycling of this product is offered to you by administrative units, household waste treatment organizations or the point of sale where you purchased the product.
Before use, carefully read the manual not only for the thermostat but also for the heating device (heat pump, etc.)
Quick start and tips
Temperature changing, programming heating schedules (at what hour the program starts), and all confirmations are done by short pressing button P, when the value is blinking. You can change the values, when they are blinking, by pressing buttons(decrease value) or (increase value) and again confirming the values by short pressing button P. To exit any editing just short press the button R. All values, and settings will be saved. Also if you are editing settings or configuring the device and you don’t press any button for 20 seconds, the device will exit the current editing and save its current values.
Button description
Display description
Battery installation
First, remove the rear cover from the room unit. Do this by carefully pulling the cover from the top and bottom of the cover and pulling it outwards. Then insert two AA (LR6) 1.5V batteries the correct polarity. After insert the unit’s back cover.
Installation of the room unit
You can place the thermostat on the wall in the desired room or on the attached bracket, with which you can have the unit anywhere in the room. Perform the wall mounting by removing the back cover and marking where you will drill holes for it. Then, screw the cover into the designated, marked place and “attach” the room unit. Place the thermostat in a location where it is not directly exposed to a heat source or to sunlight (example in the picture). The receiver should not be mounted directly on the metal surface.In the case of using the bracket, just slide the unit into the bracket.
Advice on thermostat installation and position in the room
Short description of possible errors, the device might show on the display:
Error shown on display | Description |
Crossed battery | Bad batteries – requires the replacement of batteries as soon as possible. |
roomERR | Thermostat sensor failure. |
No display or the display is malfunctioning | Temporary display malfunction. Press reset button softly. |
Unable to unlock the thermostat, I forgot the code | Remove the batteries from the thermostat for a longer period of time (60 min +) or press the reset button with a clip or some thin object. The thermostat will restart unlocked. Go to the settings and set the code you want. |
I changed the settings and now the thermostat is not working as it should. I want to reset them to factory defaults. | Go to the settings menu. Press and hold the R. key for 3 seconds. The display shows “def”. The settings will be reset to factory default values. |
Er2 | Error in connection with the receiver. Check the connection. Check that the receiver is turned on and that the devices are within range. Repeat pairing with the receiver. |
If the device is not in use for a long time and there is no need for heating, remove the batteries to prevent battery leakage and extend the battery life.
Setting the clock
Pressing the button enters the clock and day setting mode. When in editing mode, the current setting position will blink. First, you are setting the time – hours and minutes. You can change the value by pressing or buttons. When you are done setting the time, press the button and you will continue to set the current day. Again, you change the value by pressing \ buttons. When you are done setting the time/date values, press the R button to exit and save.
Programming the heating modes and schedules
By short-pressing the P key, you enter heating mode programming. For every program and schedule you can look up to the default tables on the next pages. When you are in editing mode, you can use the P button to switch between the settings (days, clock, temperature and timer) and keys to change the desired values (when the selected value flashes). We can choose the settings for 7, 5 + 2, 5 + 1 + 1 days and 4 or 6 time switches. As the default program schedule setting is set the 7-day program with 6-time programs. For changing these values, please refer to advanced settings. If you won’t change any of the schedules, the default settings will stay. For reference, check the tables in the next pages. If you are not happy with the settings you’ve made, you can always set them back to factory default by holding button R for 3 seconds. All changes made to the schedules will be lost and set to factory default! The display will show dEF. When editing, if you don’t press any button for about 15 seconds, the device will save any changes made until then. You can return to editing by going back with the same procedure.
Example of setting the default 7-day schedule with 6 switches. Use the tables at the start of this manual for reference.
To access advanced thermostat settings, turn off the device by briefly pressing
Settings explanation
Step | Setting name (default value) | Change option | Description |
1 | CL (0) | -4 do +4 | Temperature display correction |
2 | AH (35.0) | 20 – 35 (v °C) | Maximum output, operating temperature |
3 | AL (5.0) | 5 – 20 (v °C) | Lowest output, operating temperature |
4 | FC (C) | C / F | Temperature display in Celsius or Fahrenheit |
5 | bL (05) | 00 / 05 / 15 | Backlight duration in seconds |
6 | db (0.5) | 0.2 – 5.0 | Temperature range: temperature difference between switching on and off. If, for example, the temperature on the system is set at 22 ° C and the range at 0.5 ° C the heating system starts to operate if the room temperature drops to 21.5 ° C and switches off when the temperature reaches 22.5 ° C. A smaller set hysteresis can affect the life of the thermostat and the connected devices! |
Settings continue on the next page |
Step | Setting name (default value) | Change option | Description |
7 | P51 (7) | 0 / 2 / 3 / 7 | Programming option 7: Separate setting for each day 3: 5 days + 1 + 1 2: 5 days + 2 weekends 0: programs disabled |
8 | P52 (6) | 4 / 6 | Number of time programs: In one day we can have 4 or 6 different hour and temperature regimes. (see the tables below) |
9 | OC(24) | 12 / 24 | 24 hours or 12 hours clock display |
10 | ES (OFF) | On / Off | Smart Adaption, Adjustment – If you have this feature turned on, the thermostat will start heating and functioning before the next heating program is switched on and will try to get to the desired temperature as comfortable as possible. If this function is turned on, the device is constantly learning and adjusting, and calculates how much sooner it has to start with the heating. This is done by algorithm learning curve. |
11 | Ad (30) | 5 – 90 | Setting the room temperature refresh rate in seconds. Here you can adjust how quickly the sensor will refresh the room temperature display. Faster is more accurate but has more fluctuations. More seconds equals more stable operation and room comfort. |
12 | Cod (0000) | 0000-9999 | Keypad unlock code setting. With P button you can move over different code position setting. |
Temporary temperature change (Temporary hold)
The device has the option of temporarily changing the temperature with the option “temporary hold”. This option is simply activated by manually changing the temperature. If the option is activated, “TEMPORARY HOLD” appears on the screen (see display description, No. 11). The desired temperature remains active until the change of program schedule occurs. With the button, you can also cancel the activated option.
Constant temperature change (Permanent hold)
The device has the option of constant temperature change with the option “permanent hold”. The option allows you to keep a constant temperature every day and hour of the week, independent of the program settings as it overrides them. This option is simply activated with a long press (5 seconds). If the option is activated, “PERMANENT HOLD” appears on the screen (see display description, No. 11). Set the desired temperature using buttons. The “permanent hold” option remains active until it is canceled briefly.
Key Lock and unlock with code feature
This feature allows you to lock the thermostat, and when the function is turned on, any changes to the settings are disabled. Activate the function by holding down q and p buttons at the same time for three seconds. When the function is activated, the lock symbol is displayed (see display description – 14). You can switch off the function (unlock the thermostat) by again holding q and p keys for 3 seconds and then enter the unlock code you’ve set in the thermostat settings (default 0000). To set the next code, press the P. key. Change the number with q and p. Confirm the code with R. The code can be changed in the advanced thermostat settings. The lock symbol disappears on the screen. The lock symbol disappears on the screen.
Automatic OPEN WINDOW detection function
The thermostat has automatically turned on the function of detecting if there’s an open window nearby. The function turns on, when the room temperature suddenly falls for 1.5°C or more in the last 3 minutes and then the thermostat turns off the heating to prevent unnecessary energy loss. The function turns off when the room temperature increases or after 30 minutes after the function activates or if the user presses any of the thermostat’s buttons. The thermostat then returns to its previous working mode.
Smart adjustment
The thermostat has the option of activating the smart adjustment function, which allows the thermostat algorithm to learn the last 7 days of heating and to predict how long it takes to start heating to reach the desired set temperature
The units of the transmitter (thermostat or room unit) and the receiver are connected (paired) by default. If not, follow the procedure below:
The process is complete. Switch on both devices! Now test the communication by raising and lowering the heating temperature on the thermostat – the receiver should confirm the communication by briefly flashing the yellow indicator and turning it on or off. turning off the heating. If the process was unsuccessful, repeat the process from the beginning or get help on our website, youtube channel or contact us at help@sen-controls.eu.
Warning: The contents of these instructions can be changed without prior warning – due to limited printing options, the symbols presented may vary slightly from the on-screen symbols – the contents of these instructions cannot be reproduced without the consent of the manufacturer. The device can be freely used in the EU. All statements of conformity (CE, RoHS) are freely available on the website www.sen-controls.eu and subsites eg. https://en.sen-controls.eu or other. The documents are also available on product subsites under or on request by email at info@sen-controls.eu.
WARRANTY CARD AND INSTRUCTIONS FOR THE RECLAMATION PROCEDURE
The owner invokes a guarantee claim by declaring the impairment to an authorized workshop, repairer, point of sale, either in writing or orally. The buyer is responsible if he causes damage to the appliance by late notification. Upon expiration of the warranty period, the right to claim a warranty claim has expired. The validated warranty card with the original invoice must be attached. Sen Controls d.o.o. undertakes to replace the device with a new one if it fails to function properly in this warranty period.
Please add a detailed explanation of the error of the device, along with a properly completed warranty card.
Type of the device | Wireless thermostat |
Manufacturer | SASWELL |
Model | SAS908XWHB-7-RF(SL1) |
Date of purchase | |
SIGNATURE AND STAMP OF THE SELLER |
The distributor, import, and service for EU is Sen Controls d.o.o., Belokranjska cesta 29, 8340 Črnomelj, Slovenia, tel.: +386 40 299 299 www.sen-controls.eu
info@sen-controls.eu
If you have any questions or problems with our products, contact us on help@sen-controls.eu.
Download Manual:
Saswell SAS908XWHB-7-RF Double Way Wireless Thermostat User Manual
Saswell SAS908XWHB-7-RF Double Way Wireless Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…