This programmer can automatically switch your central heating or hot water ON and OFF up to 3 times a day, at whatever times you choose. Timekeeping is maintained through power interruptions by a nonreplaceable battery designed to last for the lifetime of the programmer. The clock is automatically put forward 1 hour at 1:00am on the last Sunday of March and back 1 hour at 2:00am on the last Sunday of October. The clock is factory pre-set to UK time and date, but you can alter the time setting if you wish. During installation, the installer selects 24 hour, or 5 day/2day, or 7 day programming and 2 or 3 on/off periods per day, via a 4 position DIP switch on the back of the unit (see installation instructions
Configuration
When setting time, date or changing programme times the first screen displayed indicates the configuration as set up by the installer. (See ‘Setting The Time section)
Configuration | Display |
2 ON/OFF Pumped System | 2PU |
3 ON/OFF Pumped System | 3PU |
Times for Central Heating and How Water can be independently set. |
The 24 hour, or 5 day/2day, or 7 day programming option as set up by the installer can also be verified at this stage by how the Monday to Sunday indicators are displayed
Programming Option | Mon to Sun Indicators flash |
7 DAY | Mon to Sun individually shown |
5/2 DAY | Mon to Fri together then Sat & Sun together |
24 HOUR | Mon to Sun together shown |
Built In Programme
For convenience, the programmer has a built in programme which will be satisfactory for many people, but which can be changed very easily (see section CHANGING PROGRAMME TIMES). Once the unit is powered up this built in programme will run. If the user changes from the built in programme and wishes to return to it, then pressing the reset button with a non metallic pointed tool will return the unit to the built in / default programme
Factory Programme Settings
2Pu | 3Pu | Mon-Fri | Sat-Sun |
1st ON | 1st ON | 6:00am | 7:00am |
1st OFF | 1st OFF | 8:30am | 9:00am |
– | 2nd ON | 12:00 noon | 12:00 noon |
– | 2nd OFF | 12:00 noon | 12:00 noon |
2nd ON | 3rd ON | 4:30pm | 4:30pm |
2nd OFF | 3rd OFF | 10:30pm | 11:30pm |
ON | Central Heating and Hot Water is ON continuously |
AUTO | Central Heating and Hot Water will be switched ON or OFF as programmed |
ALL DAY | Central Heating and Hot Water will be switched ON only once each day between the first ON time and last OFF time |
OFF | Central Heating and Hot Water is OFF continuously |
Setting The Time
Setting The Date
Changing Central Heating Times
Changing Hot Water Times
Press SET button until tap icon [3] flashes in the display and 1 ON [4] appears. This indicates the time shown on the display is the first ON time and proceed in same manner as ‘To change the Central Heating Times’ above.
7 Day Programmer Option
If the unit is installed as a 7 day programmer, the initial programme displayed will be for Monday. You can go to any date of the week by pressing the DAY button repeatedly. The ON/OFF times can be changed for each day as described above in the section “CHANGING PROGRAMME TIMES”. If you press the COPY button, the current programme will be copied onto the next day.
NOTE: it is not possible to copy Sunday to Monday
5/2 Day Programmer Option
If the unit is installed as a 5 day/2 day programmer, the initial programme displayed will be for Monday to Friday. Pressing the DAY button will take you to the programme for Saturday and Sunday. The ON/OFF times can be changed for each day group as described above in the section “CHANGING PROGRAMME TIMES”. If you press COPY button, the current programme will be copied onto the next day group.
24 Hour Programmer Option
If the unit is installed as a 24 hour programmer, the built in programme will be the same for each day. The COPY & DAY buttons have no affect if installed as a 24 hour programmer
Programming Notes
Reset
Press the reset button with a non-metallic pointed tool to restore the built in programme. As well as restoring the built in programme, it also resets the time to 12:00pm and the date to 01/01/2014. Initially the display shows all segments lit for a few seconds, but then will show the current configuration. See ‘Setting The Time’ section to continue. As a safety feature after reset the unit will be in OFF operating mode. Reselect your required operating mode.
The ADVANCE function allows the user to move to the next ON or OFF programme for a “one off” event, without having to change the program or change the operating mode.
Warning: The ADVANCE function is only available when programme is in AUTO or ALL DAY operating modes.
To advance Central Heating 1 or 2 Press the appropriate Central Heating channel ADV button. This will turn the Central heating ON if it is in an OFF period and OFF if it is in an ON period. It will stay in this state until either ADV button is pressed again, or until a programmed ON/OFF period commences. The word ADV [5] will appear in the left hand of the LCD.
To advance Hot Water Press the Hot Water channel ADV button. This will turn the Hot Water ON if it is in an OFF period and OFF if it is in an ON period. It will stay in this state until either ADV button is pressed again, or until a programmed ON/OFF period commences. The word ADV [5] will appear in the tleft of the LCD
For +Hr Central Heating 1 or 2
Press the appropriate Central Heating channel +HR button to make the desired selection with one, two or three hours extra heating [6] and cancel options offered.
Warning: The +HOUR function is only available when programme is in AUTO, ALL DAY or OFF operating modes. If the Central heating operating mode is OFF, then it will switch on for the extra hours selected. If the Central heating mode is AUTO or ALL DAY, then during an OFF period, it will switch on for the extra hours selected. If during an ON period, then it will temporarily extend that programme by the number of hours selected.
For +Hr Hot Water
Press the Hot Water channel +HR button. to make the desired selection with one, two or three hours extra heating [6] and cancel options offered.
Warning: The +HOUR function is only available when programme is in AUTO, ALL DAY or OFF operating modes. If the Hot Water operating mode is OFF, then it will switch on for the extra hours selected. If the Hot Water mode is AUTO or ALL DAY, then during an OFF period, it will switch on for the extra hours selected. If during an ON period, then it will temporarily extend that programme by the number of hours selected.
NOTE: If the programmer is in the OFF mode and then +HR button is pressed (+1 HR, + 2 HR, or + 3 HR) and the resulting time of the boost overlaps a START / ON time in the AUTO mode program memory then the boost will disengage. If this happens simply press +HR button again and the boost will activate for the time period chosen
The Holiday function allows the user to turn all channels to the OFF operating mode, for a settable amount of days from 01-99 days. During this function a suitcase icon will be displayed.
The number of days will decrease at midnight each day. The +HR boost override can be used during a holiday period.
Power Interruption
In the event of a mains supply failure the screen will go blank but the back-up battery ensures that the programmer continues to keep the time and retain your stored programme. When power is restored, if there has been no change to the rear DIP switch, the programmer returns to its expected operating condition. If the configuration setting on the rear DIP switch has been altered during the power interruption the screen will initially show the new configuration. And the appropriate factory default programme (see BUILT IN PROGRAMME section) will be installed. Press SET button to return to RUN mode.
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT. This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively, return end of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we welcome your comments and complaints, as it can help us to improve our services to you, our customer. Due to our policy of continuous product improvement and development, the specifications in this guide may be subject to change without prior notice.
Sangamo
Download Manual:
Sangamo PR3n Programmable Thermostat User Instructions
Other Manual:
Sangamo PR3n Programmable Thermostat Product Specification Guide
Sangamo PR3n Programmable Thermostat Installation Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…