Before installing, set the bank of 4 DIP Switches on the back to configure the unit according to the chart below:
DIP Switches Shown in Factory Default Positions. (black = raised actuator of the switch)
PUMPED allows independent control of CH and HW.
GRAVITY does not allow CH without HW but can provide HW without CH.
This unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring Regulations. Isolate mains supply before commencing installation. Please read all installation instructions before proceeding. Ensure that the fixed wiring connections to the mains supply are via a fuse rated at not more than 3 amps and a class ‘A’ switch having a contact separation of a minimum of 3mm in all poles. The recommended cable sizes are 1.0mm2 or 1.5mm2 If the unit is fitted to a metal surface, IT IS ESSENTIAL that the metal be earthed. DO NOT use a surface mounting box.No earth connection is required as the product is double insulated but ensure continuity of earth throughout the system.
Example circuit diagrams for typical installations are shown over. These diagrams are schematic and should be used as a guide only. Please ensure that all installations comply with the current IEE regulations. For reasons of space and clarity, not every system has been included and the diagrams have been simplified, for instance, some Earth connections have been omitted. Other control components are shown in the diagrams i.e. Valves, Room Stats, etc. are general representations only. However, the wiring detail can be applied to the corresponding models of most manufacturers.
New Installations
Cylinder and Room Thermostat Key:
C=Common Call = Call for heat or break on rise SAT = Satisfield on rise N= Neutral
Fitting The Programmer
Loosen the two retaining screws on the bottom of the back plate. Now fit the programmer to the back plate, ensuring the lugs of the back plate engage with the slots on the programmer.
Swing the bottom of the programmer into position ensuring the connection pins on the back of the unit are located in the terminal slots in the back plate. Tighten the two screws to fix the unit securely.
Switch on the mains supply. Referring to the user guide:
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery, and/or disposal. End-of-life products should be handled in line with local regulations. Alternatively, return end-of-life products to Sangamo for correct disposal.
CUSTOMER CARE POLICY As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we welcome your comments and complaints, as they can help us to improve our services to you, our customer. Due to our policy of continuous product improvement and development, the specifications in this guide may be subject to change without prior notice.
Download Manual:
Sangamo PR2n Programmable Thermostat Installation Instructions
Other Manual:
Sangamo PR2n Programmable Thermostat Product Specification Guide
Sangamo PR2n Programmable Thermostat User Instructions
Sangamo PR2n Programmable Thermostat Installation Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…