Transmitter
Receiver
There are one 4 DIP switch on the back of the receiver and one 4 DIP switch + one 3 DIP switch on the back of the thermostat.Before installation, the installer needs to set the DIP switches first. The 4 DIP switches are used for RF code setting. The thermostat and receiver are automatically paired when you receive them, however, if there is another unit nearby(e.g. in a neighbours home) the thermostat may tigger their receiver. To avoid this you can change the RF address code on both the thermostat and receiver as per Fig.3. The 3 DIP switch on the thermostat is used to set below control modes. Please set the position of the DIP switch as per the DIP switch label(see Fig.3)
TPI ON/TPI OFF: The default setting is TPI off. When TPI is set to off,the thermostat will work based on hysteresis algorithm.With this algorithm,when the difference between the room and the setpoint temperatures is less than the sensitivity threshold( 0.5°C and 1.0°C optional, please refer to the operation guide for setting the sensitivity threshold/switching differential ),the thermostat considers it has reached the setpoint temperature. When TPI is set to on,initially only hysteresis algorithm is available. After your thermostat has been in use for a short duration, the thermostat will have learned your home characteristics, such as your thermal inertia and your heating insulation. then the thermostat will switch to work as per TPI control automatically for a better temperature regulation. if the location of the thermostat is changed from one room to another room, the user needs to set the DIP switch to OFF position first and then reset to ON position again, so that the thermostat can relearn your room characteristics for best TPI performance
Optimum Start/Delayed Start: The default setting is optimum start. When this mode is selected, you set the time you want to be warm and Optimum Start will do the rest. On warmer days it will start later. Optimum Start ensures that you are warm when you want to be (and not before), reducing wasted energy and saving money. When delayed start has been selected, You set the earliest start time, based on an estimate and Delayed Start will do the rest. Delayed Start will delay the boiler firing time on warmer days, when it is possible to save energy.
Delayed Stop ON/ Delayed Stop OFF: The default setting is Delayed stop OFF. When Delayed Stop is OFF, the thermostat will turn off the heater as per hysteresis algorithm or TPI control normally. When Delayed Stop is ON, the thermostat will calculate how long the house will take to cool down , then turns off the boiler at the earliest possible moment, when it calculates that the temperature will not decay by more than 1/2℃
There are three easy steps for installation of the receiver: Step one: Flip down the front plate; Step two: Wiring according to the diagram and the labelled ports of the switch; and Step three: Install the switch in the wall or mounting box with screws (as shown in Fig.3 ) When cutting the aperture for the output flexible cord, ensure no sharp edges remain
There are two easy steps to fix the stand
This unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring Regulations. Isolate mains supply before commencing installation. Please read all installation instructions before proceeding. Example circuit diagrams for typical installations are shown. These diagrams are schematic and should be used as a guide only. Please ensure that all installations comply with the current IEE regulations. For reasons of space and clarity not every system has been included and the diagrams have been simplified, for instance some Earth connections have been omitted. Other control components shown in the diagrams i.e. Valves, Room Stats etc. are general representations only. However, the wiring detail can be applied to the corresponding models of most manufacturers. Your product is not user serviceable. Do not dismantle this product. Due to our policy of continuous product improvement and development, the specifications in this guide may be subject to change without prior notice.
Sangamo
Download Manual:
Sangamo CHPRSTATDPRF Wireless Digital Programmable Thermostat Installation Instructions
Other Manual:
Sangamo CHPRSTATDPRF Wireless Digital Programmable Thermostat User Instructions
Sangamo CHPRSTATDPRF Wireless Digital Programmable Thermostat Product Specification Guide
Sangamo CHPRSTATDPRF Wireless Digital Programmable Thermostat Installation Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…