CHPPR2 is a two channel programmer, designed for separate control of your heating and stored hot water. The heating and hot water programs are independent of each other, giving you the opportunity to save money and control your heating in the most energy saving manner possible
Open the front cover to show the hidden panel and complete all the settings as per below operation guide.
Configuration
When setting time, date or changing programme times the first screen displayed indicates the configuration as set up by the installer. (See ‘Setting The Time section)
The 24 hour, or 5 day/2day, or 7 day programming option as set up by the installer can also be verified at this stage by how the Monday to Sunday indicators are displayed.
Built in Programme
For convenience, the programmer has a built in programme which will be satisfactory for many people, but which can be changed very easily (see section CHANGING PROGRAMME TIMES). Once the unit is powered up this built in programme will run. If the user changes from the built in programme and wishes to return to it, then pressing the reset button with a non metallic pointed tool will return the unit to the built in / default programme
Factory Programme Settings
If the unit is installed as a 24 hour programmer, the built in programme will be the same for each day (i.e. Sat-Sun be same as Mon-Fri above
2 PU & 2 Gr | 3 PU & 3Gr | Mon – Fri | Sat – Sun |
1st ON | 1st ON | 6:00am | 7:00am |
1st OFF | 1st OFF | 8:30am | 9:00am |
– | 2nd ON | 12:00 noon | 12:00 noon |
– | 2nd OFF | 12:00 noon | 12:00 noon |
2nd ON | 3rd ON | 4:30 pm | 4:30 pm |
2nd OFF | 3rd OFF | 10:30 pm | 11:30 pm |
ON | Central Heating and Hot Water is ON continuously |
AUTO | Central Heating and Hot Water will be switched ON or OFF as programmed |
ALL DAY | Central Heating and Hot Water will be switched ON only once each day between the first ON time and last OFF time |
OFF | Central Heating and Hot Water is OFF continuously |
Setting the Time
Setting the Date
Change Central Heating Times
Change Hot Water Times
Press SET button until tap icon [3] flashes in the display and 1 ON [4] appears. This indicates the time shown on the display is the first ON time of hot water(see Fig. 10) and proceed in same manner as ‘To change the Central Heating Times’ above.
7 Day Programmer Option
If the unit is installed as a 7 day programmer, the initial programme displayed will be for Monday.You can go to any date of the week by pressing the DAY button repeatedly. The ON/OFF times can be changed for each day as described above in the section “CHANGING PROGRAMME TIMES”. If you press the COPY button, the current programme will be copied onto the next day
5/2 Day Programmer Option
If the unit is installed as a 5 day/2 day programmer, the initial programme displayed will be for Monday to Friday. Pressing the DAY button will take you to the programme for Saturday and Sunday. The ON/OFF times can be changed for each day group as described above in the section “CHANGING PROGRAMME TIMES”. If you press COPY button, the current programme will be copied onto the next day group.
24 Hour Programmer Option
If the unit is installed as a 24 hour programmer, the built in programme will be the same for each day. The COPY & DAY buttons have no affect if installed as a 24 hour programmer.
Programming Notes
The unit will automatically return to normal running mode if a period of 30 seconds passes without any buttons being pressed. Programming past midnight is NOT allowed. To overcome this the program needs to be split in two parts from midnight as per example-
Reset
Press the reset button with a non-metallic pointed tool to restore the built in programme.As well as restoring the built in programme, it also resets the time to 12:00pm and the date to 01/01/2020. Initially the display shows all segments lit for a few seconds, but then will show the current configuration. See ‘Setting The Time’ section to continue.
The ADVANCE function allows the user to move to the next ON or OFF programme for a “one off” event, without having to change the programme or change the operating mode
To Advance Central Heating:
Press the Central Heating channel ADV button. This will turn the Central heating ON if it is in an OFF period and OFF if it is in an ON period. It will stay in this state until either ADV button is pressed again, or until a programmed ON/OFF period commences. The word ADV [5] will appear in the left hand of the LCD
To Advance Hot Water
Press the Hot Water channel ADV button. This will turn the Hot Water ON if it is in an OFF period and OFF if it is in an ON period. It will stay in this state until either ADV button is pressed again, or until a programmed ON/OFF period commences. The word ADV [5] will appear in the tleft of the LCD
For +Hr Central Heating:
For +Hr Hot Water
Holiday Mode
The Holiday function allows the user to turn all channels to the OFF operating mode, for a settable amount of days from 01-99 days. During this function, a suitcase icon will be displayed
Power Interruption
In the event of a mains supply failure, the screen will go blank, but the programmer continues to keep the time and retain your stored programme. When power is restored, if there has been no change to the rear DIP switch, the programmer returns to its expected operating condition. If the configuration setting on the rear DIP switch has been altered during the power interruption, the screen will initially show the new configuration. And the appropriate factory default programme (see BUILT IN PROGRAMME section) will be installed. Press SET button to return to RUN mode.
Service Interval Function Setting:
If you are a tenant, under The Gas Safety (Installation & Use) Regulations 1998, your private landlord, local authority or housing association must carry out a 12 monthly gas safety check tomake sure gas fittings and appliances are safe to use If set by the installer, 28 days prior to the boiler service due date, a rotating visual warning message SEr, dUE, dXX will remind you that a service is due (XX shows the number of days remaining in the warning period).
The display backlight will also flash on and off from 7 days prior to the boiler service due date. During this warning period, the programmer will continue to operate normally and you have full access to all its features.
If the boiler is not serviced within the 28 days then the programmer will operate only according to one of two settings (selected by the installer on installation). All buttons will be disabled. The display backlight will continue to flash.
A visual warning message OFF, SEr, dUE indicates the installer has set the programmer for a Total Shutdown and your heating/hot water will no longer operate.
A visual warning message 15, rUn, SEr, dUE indicates the the installer has set the programmer for a Partial Shutdown and your heating/hot water will operate for a random15 minute portion of each programmed hour only Therefore, to ensure your comfort level is maintained, it is important to respond to any requests for a gas safety check/boiler service appointment and to keep to the appointment. Contact details for the installer/landlord may be shown on a Service Contact label affixed to the product. The installer will cancel or reset the Service Interval Timer as part of the safety check/ boiler service.
HEALTHY AND SAFTEY
This unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring
Regulations.
Isolate mains supply before commencing installation. Please read all installation instructions before proceeding.
Example circuit diagrams for typical installations are shown. These diagrams are schematic and should be used as a guide only. Please ensure that all installations comply with the current IEE regulations. For reasons of space and clarity not every system has been included and the diagrams have been simplified, for instance some Earth connections have been omitted. Other control components shown in the diagrams i.e. Valves, Room Stats etc. are general representations only. However, the wiring detail can be applied to the corresponding models of most manufacturers. Your product is not user serviceable. Do not dismantle this product. Due to our policy of continuous product improvement and development, the specifications in this guide may be subject to change without prior notice.
Sangamo
Download Manual:
Sangamo CHPPR2 Programmable Thermostat User Instructions
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…