The SALUS Quantum WQ610 and WQ610RF thermostats are Boiler Plus compatible thermostats, designed specifically to control central heating boilers and also in the case of the RF versions, electrical panel heaters. They have our new load compensation (ITLC) software with Volt free switch and also Opentherm 4.0 connections, so you can choose the method of control to suit your boiler/installation. Please note that the Boilers need to have an OpenTherm Association license to be fully compatible with WQ610 range(should you wish to connect to the OpenTherm terminals A and B). Please verify if this requirement is met with your Boiler Manufacturer.
This product complies with the essential requirements and other relevant provisions of the following EU Directives: RED:2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on: www.saluslegal.com WQ610RF: 2405-2480MHz; <14dBm
WQ610 Thermostat | WQ610RF Thermostat | |
Thermostat supply | 230V AC | Lithium Battery (Rechargeable) |
Thermostat rating max | 3 (1) A | – |
OpenTherm terminals | A / B | – |
Outputs | Voltage-free NO / COM terminals | – |
Temperature range | 5°C — 35°C | 5°C — 35°C |
Thermostat display accuracy | 0.5°/ 0.11 | 0.570.1X |
Thermostat display resolution | 0.5°C | 0.5°C |
ErP control class | Class V | Class V |
Radio Frequency | 2.4 61-1z | |
Dimension [mm] | 86 x 86 x 27 [mm] | 86x 86 x 11[mm] |
WQ610 Receiver | |
Receiver supply | 230 V AC |
Receiver rating max | 16 (5) A |
OpenTherm terminals | A / B |
Outputs | Voltage-free NO / COM terminals |
Radiofrequency | 2.4 Glz |
Dimension [mm] | 98 x 98 x 32[mm] |
WQ610 Thermostat Terminals Description
Terminal | Description |
A/B | OpenTherm Communication Wires only |
NO | Volt-free connection (Switch) |
COM | Volt-free connection (Common) |
L;N | Supply (230 V AC) |
WQ610RX Receiver Terminals Description
Terminal | Description |
B/A | OpenTherm Communication Wires only |
NO | Volt-free connection (Switch) |
COM | Volt-free connection (Common) |
L;N | Supply (230 V AC) |
WQ610 Wiring Diagram
To activate thermostat, press TICK buttonfor 3 seconds (RF version) only. | Language ”ENGLISH” is flashing, press UP or DOWN, choose your language, then TICK to confirm. |
Using UP or DOWN, choose the time format between 24 hr and 12 hr format. | Using UP or DOWN, set the hour and then press TICK, which will then move to minutes, that can be changed in the same way. |
Using UP or DOWN, set the year and then press TICK. | Using UP or DOWN, set the month and then press TICK, which will then move to days, that can be changed in the same way. |
If you select NO, the thermostat will use dafult settings and revert to the normal screen. | Once you have properly connected your thermostat with the Open Therm terminals the OT message will be shown on the screen. For more Opentherm details, go to the Opentherm: Configuration section. |
Advanced Settings allow the installer/landlord to adjust the thermostat to suit individual installation requirements. Do not adjust the settings unless you are competent to do so. The Advanced Settings may be locked by the creation and activation of a 4-digit PIN code. Please keep your PIN safe and secure.
Press MENU. | Using UP or DOWN, navigate to Advanced submenu and press TICK. |
Press TICK to enter Daylight Saving Time Menu. | Using UP or DOWN, select ON or OFF. Press TICK to confirm. |
Press TICK to select the type of heating control you prefer. | ITLC helps to improve system efficiency and end user comfort. The default is ITLC Radiators (disabled if Opentherm is connected). Press TICK to confirm or DOWN to see the next option. |
This option is only for electrical radiators. Press TICK to confirm or DOWN to see the next option. | This is a simple ON/OFF algorithm control based on the set point. Using UP or DOWN, you can select the SPAN value. Press TICK to confirm or DOWN to go to the next option. |
Using TICK, then UP and DOWN you can select FROST value . (5 – 17 degrees C). Press TICK to confirm or DOWN to see the next option. | Using TICK, then UP and DOWN you can set the maximum and the minimum room temperature. |
If you think that the temperature displayed on the thermostat is not accurate due to its location, you can calibrate it using this menu with values between -3.5 / +3.5 degree. | This will start your boiler early to improve energy saving. |
This will stop your boiler early to improve energy saving. | Press TICK to allow installer or landlord to set service reminders and lock the temperature level. |
Using UP or DOWN, you can select YES and press TICK to confirm,or you can select NO and go to point 20. | Using UP or DOWN, select the number of days the service alert should last for. |
Using UP or DOWN, select the warning period before the service alert will be activated, then press TICK. | Using UP or DOWN, select the lock temperature and then press TICK. |
Press TICK and enter the installer’s phone number using UP and DOWN buttons. | Allows you to create a PIN that may be used to limit access to your settings. Using UP or DOWN, create your PIN access, then tick to confirm. |
This option will allow you to lock your advanced settings using your access PIN. Using UP or DOWN, create your lock advanced settings, then TICK to confirm. | Using UP or DOWN, enter the PIN code number. Press TICK to confirm every digit. |
This option will allow you to set the displayed temperature accuracy. | The temperature display accuracy can be 0.5 or 0.1 |
Use your created PIN to lock access to the advanced settings menu. |
Temporary Manual Override
For overriding the schedule to bring the HEAT on, use the UP button to increase the temperature and press TICK to accept the change.
This setting will be valid until the next scheduled program.
This menu will only be visible if your boiler is OpenTherm compatible and you have connected to terminals A and B.
OpenTherm is a method of control used by modern heating systems. Instead of switching a boiler on and off at intervals, modulating control allows the amount of heat provided by the boiler to be controlled to match the varying demand from the thermostat. This means the customer has greater system efficiency, energy saving and room comfort from our heating controls.
CH (Central Heating) | HW (Hot Water) |
MIN TEMP: 25 °C | MIN TEMP: 40 °C |
MAX TEMP: 80 °C | MAX TEMP: 80 °C |
DEFAULT TEMP: 75 °C | DEFAULT TEMP: 60 °C |
This screen display will be displayed when OT is connected. To change the settings for DHW and/or CH – press MENU and go to ADVANCED SETTINGS. | Using UP or DOWN, navigate to HW SETPOINT and press ICK. |
Using UP or DOWN, adjust the temperature and then press TICK. | Press TICK to enter the menu. Using UP or DOWN, set the maximum open therm central heating temperature. |
Using UP or DOWN, set the value then press TICK for 3 sec to confirm and exit to the main screen. |
SERVICE REQUEST ERROR | LOCKOUT RESET ERROR |
LOW WATER PRESSURE ERROR | GAS FLAME FAULT ERROR |
AIR PRESSURE FAULT ERROR | WATER OVER TEMPERATURE ERROR |
WQ610RF: Pairing with the Receiver
Turn the receiver OFF and ON twice to reset. Ensure receiver switches are ON and AUTO. Red LED should be flashing. Enter thermostat MENU and scroll down until you will see “PAIR WITH RECEIVER” option. Select YES to proceed with Pairing.
Now your thermostat is looking for the receiver. A 10-minute counter will appear on the screen.
flashing.
Your thermostat will indicate that the connection has been tested successfully and will return to normal operation.
Head Office:
SALUS Controls Units 8-10Northfield Business Park Forge Way, Parkgate Rotherham, S60 1SD
Email: sales@salus-tech.com
www.salus-tech.com
Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change the specification, design, and materials of products listed in this brochure without prior notice.
For a PDF Installation guide please go to www.salus-manuals.com
Issue Date: Feb 2020
Download Manual:
SALUS WQ610RF Wireless Slim Programmable Thermostat Installation Guide
other manuals:
SALUS WQ610RF Wi-Fi Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…