Before setting up the thermostat, download the SALUS SOLO application on your IOS or Android device. After downloading the application, follow the steps in this guide to connect devices.
Device Boot Sequence
Mobile Setup
When a Thermostat is first powered or if a Factory Reset is performed, the above boot sequence will be displayed. The last screen displays the thermostat model and firmware version number. When the text
Manual Setup
The SALUS SOLO application is the most efficient way to configure the thermostat. If no Wi-Fi is available, you may configure the thermostat using the manual mode. Pressing any button switches displays
Connecting a Wi-Fi Thermostat to the SOLO Application
Selecting
Home Screen Elements
| Screen Element | Description |
| Main Menu | Access to Profile, Sign Out, About, Add Device, Home (This Screen) |
| Device Label | Unique identifier for each device |
| Cloud Server Connection | The icon will flash if there is an issue with connection to the cloud server . |
| Current Set Point | The current thermostat target temperature |
| Increase/Decrease Set Point | Set point adjustment . The current set point will react immediately to touch . |
| Heat/Cool Mode | Touch to cycle through OFF / HEAT / COOL / AUTO |
| Current Room Temperature | Displays the current room temperature |
| Fan Mode | Touch to toggle between ON/AUTO |
Device Detail Elements
| Setting | Description | ||
| Span | Controls the allowable difference between the set point and room temperature . | ||
| Default | Range | Increment | |
| 1°F (0 .5°C) | 1°F to 2°F (0 .5°C to 1 .0°C) | 1°F (0 .5°C) | |
| Frost Set Point | Temperature below which the thermostat calls for heat regardless of target set point . Intended to prevent freezing . | ||
| Note: Frost Protection must be Enabled for this item to be displayed | |||
| Default | Range | Increment | |
| 41°F (5°C) | Off; 41°F to 63°F (5°C to 17°F) | 1°F (0 .5°C) | |
| Frost Protection | Enable or disable frost protection to prevent freezing in the building . | ||
| Default | Range | ||
| Disable | Disable or Enable | ||
| Offset | The calibration offset changes the temperature displayed by the amount shown compared to the sensed temperature . | ||
| Default | Range | Increment | |
| 0 | -6°F to 6°F (-3°C to 3°C) | 1°F (0 .5°C) | |
| Deadband, Maximum Set Point for Heating and Minimum Set Point for Cooling are accessible only if Advanced Settingsis chosen. | |||
| Deadband | The allowable difference in temperature between heating and cooling set points in Mode . | ||
| Note: Both heating and cooling must be selected in System Settings for this item to be displayed. | |||
| Default | Range | Increment | |
| 4°F (2°C) | 2°F to 4°F (1°C to 2°C) | 1°F (0 .5°C) | |
| Maximum Set Point for Heating | The maximum allowable temperature for the heating set point . | ||
| Note: At least one heating stage must be selected in System Settings for this item to be displayed. | |||
| Default | Range | Increment | |
| 90°F (32°C) | 41°F to 95°F (5°C to 35°C) | 1°F (0 .5°C) | |
| Minimum Set Point for Cooling | The minimum allowable temperature for the cooling set point . | ||
| Note: At least one cooling stage must be selected in System Settings for this item to be displayed. | |||
| Default | Range | Increment | |
| 50°F (10°C) | 41°F to 95°F (5°C to 35°C) | 1°F (0 .5°C) | |
| Setting | Description | |
| Temperature Display | Temperature units in degrees Fahrenheit (US Customary Units) or Celsius (SI Metric) . | |
| Default | Range | |
| °F | °F/°C | |
| Hour Format | 12- or 24-hour time format . | |
| Default | Range | |
| 12:00 | 12:00/24:00 | |
| Time Zone | North American time zone selection . | |
| Default | Range | |
| Pacific | Alaska, Central, Eastern, Hawaii, Mountain, Pacific | |
| Setting | Description | |||
| HVAC Type | Choose Conventional for furnace or boiler applications, choose Heat Pump for electric heat pumps, choose dual fuel for gas/electric systems . | |||
| Default | Range | |||
| Conventional | Conventional, Heat Pump, Dual Fuel | |||
|
Heat/Cool Stage | Number of heating (H) or cooling (C) stages with or without Auxiliary/Emergency Heat (+Aux/E) | |||
| Default | HVAC Type | Range | ||
| ST920WF | ST921WF | |||
| 1H | Conventional | 1H, 2H, 1H1C, 2H1C,2H2C, 1H2C, 1C, 2C | 1H, 2H, 1H1C, 2H1C,1H2C, 1C, 2C | |
| Heat Pump | 1H, 1C, 1H1C, 1H+AUX/E,1H1C+AUX, 2H, 2C, 2H2C, 2H+AUX/E, 2H2C+AUX/E | 1H, 1C, 1H1C, 1H+AUX/E,1H1C+AUX, 2H, 2C, 2H2C | ||
| Dual Fuel | 2H, 2H1C, 3H, 3H2C | 2H, 2H1C | ||
| Fan Control | Choose the energy input type (gas or electric) for fan control logic . | |||
| Note: Conventional HVAC Type must be selected for this item to be displayed. | ||||
| Default | Range | |||
| Gas | Gas or Electric | |||
| Changeover | Choose B (Cool Default) or O (Heat Default) for Heat Pump Systems . | |||
| Note: Heat Pump or Dual Fuel HVAC Type must be selected for this item to be displayed. | ||||
| Default | Range | |||
| B | B or O | |||
SALUS SOLO Wi-Fi Thermostats are configured as Non-Programmable by default. Use the following instructions to set up a programmable schedule on the device.
SALUS NA, Inc.
(888) 387-2587
sales@salusinc.com
www.salusinc.com
Copyright © SALUS North America, Inc. 2020
Download Manual
Salus ST921WF 2H 1C Wi-Fi Thermostat User Manual
Other Manual
Salus ST921WF 2H/1C Wi-Fi Thermostat Product Specification Guide
Salus ST921WF 2H/1C Wi-Fi Thermostat Installation Guide
Bad Ragaz Casino No Deposit Bonus Codes For Free Spins 2026 Details pertaining to the…
Online Slot Games For Money Playing online casinos UK on a mobile device Spin the…
Prime Fortune Casino No Deposit Bonus Codes For Free Spins 2026 Fantasy sports became a…
Online Casino Real Money Uk No Deposit Get ready to play the most realistic card…
Sin88 Casino No Deposit Bonus Codes For Free Spins 2026 This can be part of…
How To Always Win Blackjack Casino offer terms and conditions in UK Here is how…