RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allow us to use various operating modes – automatic (time schedules), manual, frost protection, or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com
Use in accordance with national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
RT510 Thermostat | RT510TX Thermostat | |
Thermostat supply | 2x AA alkaline batteries | 2 x AA alkaline batteries |
Thermostat rating max | 3 (1) A | – |
Outputs | Voltage free NO / COM / NC terminals | – |
Temperature range | 5 – 35°C | 5 – 35°C |
Temperature accuracy | 0.1°C or 0.5°C | 0.1°C or 0.5°C |
Control algorithm | TN or hysteresis ±0.25°C | TPI or hysteresis ±0.25°C |
Radiofrequency | – | 868 MHz |
Dimension [mm] | 120x96x27 | 120x96x27 |
RXRT510 Receiver | |
Receiver supply | 230 V AC |
Receiver rating max | 16 (5) A |
Outputs | Voltage free NO / COM terminals |
Radiofrequency | 868 MHz |
Dimension [mm] | 96x96x27 |
1. Boost function 2. Manual Mode 3. Frost protection / Holiday Mode 4. Increase button 5. Decrease button | 6. When in Manual Mode, ON will turn the boiler on. 7. When in Manual Mode, OFF will turn the boiler off. 8. Receiver operates in automatic mode according to the thermostat 9. Receiver output is controlled by the On/Off slide switch. |
1. Day of the week 2. Program number 3. Program indicator 4. Settings 5. Temperature measured / set 6. Boost function 7. Low battery status 8. Wireless connection with the receiver | 9. Heating Mode On 10. Manual Mode On 11. Holiday Mode On 12. Frost Protection Mode On 13. Temperature unit 14. AM / PM 15. Clock |
Terminal | Description |
1 – COM | Common Terminal |
2 – NC | Switched Live OFF |
3 – NO | Switched Live ON |
Terminal | Description |
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
Control feature | TPI | Span |
Operation | When TPI is selected on DIP switch № 2, the IP switch № 1 is functional. You can choose the Cycles Per Hour between a lower comfort level (6CPH) and a higher comfort level (9CPH). | When Span is selected on DIP switch № 2, the DIP switch № 1 is not functional. The thespian value is set to ± 0.25°C – it is recommended to use with heating devices. |
In this mode, the user can set the schedules for the thermostat (temperature setpoints for a specific period of time). You have the option to choose between a 5-2 days program or a daily one by using the parameter d04 from Installer mode. Programmed schedules should use all time periods.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule – it will be maintained until the next time interval tarts according to a programmed schedule.
Manual Mode and setting setpoint temperature
In this mode, the thermostat does not work according to the programmed schedule but it will maintain the selected temperature.
Press
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, the thermostat returns to the previous model.
Turning off hourly temperature override mode before time’s up
Turning Off the Frost Protection mode
In this mode, the “frost protection” temperature is maintained for a specific number of days.
If you want to re-pair the thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Next switch to the OFF position and again to the ON position quickly. The red flashing LED will confirm entering the pairing mode.
Begin the pairing process
End the pairing process
Once devices are successfully paired, the LED on the receiver will go solid red.
Press and hold the TEST / PAIRING button for 3 seconds to end the pairing process.
Test the pairing process
dxx | Function | Parametr | value |
d01 | Temperature display increments | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/- 3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C – 17.0°C | 5.0°C |
d04 | Programmer selection | 5/2 or 24 hr (7d) | 52 d |
Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.
Remove the batteries without pressing any button.
Wait 2 minutes and insert the batteries again.
Your device will be restarted.
Download Manual
SALUS RT510RF+ Programmable Room Thermostat Installation Guide
SALUS RT510RF Programmable Room Thermostat User Manual
SALUS RT510RF+ Programmable Room Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…