This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU and 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Care for the natural environment is of paramount importance to us. The awareness that we manufacture electronic devices obliges us to dispose of used electronic components and devices safely. Therefore the company has received a registration number issued by the Chief Inspector for Environmental Protection. The crossed out symbol the trash can on the product means that the product must not be disposed of with ordinary waste containers. Sorting waste for recycling helps to protect the environment. It is the user’s responsibility to surrender used equipment to a designated collection point for recycling waste from electrical and electronic equipment.
The RT510 room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy. The heating system will not work if a time switch or programmer has switched it off. The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18⁰C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.
Please note:
The ideal position to thermostat mounting is about 1,5m under floor level far from heating or cooling sources. The thermostat can’t be exposed to sunlight or any extreme conditions like for example draft.
Because of fire and explosion risk there is not allowed to use the thermostat in an atmosphere of explosive gases and flammable liquids (eg coal dust). In case if any of listed dangers occur you have to use additional protection measures – anti-dust and explosive gases (tight cover) or prevent their formation.
Furthermore, thermostats can’t be used in condensation of water vapor conditions and be exposed to water action.
PLEASE NOTE! The LCD screen can be activated by using any button.
To power up the thermostat you have to put the batteries inside. Then thermostat will display following sequence:
In this chapter you can set time and day of the week. RT510 thermostat has no date settings. You can choose the day of the week (from Monday to Sunday).
Please follow the steps below:
RT510 thermostat offers few operating modes:
In manual mode, the thermostat maintains a constant temperature set by the user. To set temperature setpoint follow steps below:
To turn off the Manual Mode press button. Once the manual mode is off, the hand icon on the thermostat will disappear.
In this mode, the user can set the schedules for the thermostat (temperature setpoints for specific periods of time). There are two types of schedules: 5/2 (working days+weekends) and 7d (7 individual schedules for each day separately). The schedule type can be chosen by parameter d04 (please refer to the Installer mode section). The schedule is divided by 6-time programs (which means the user can have a maximum of 6 temperature changes during a day). To program a schedule its necessary to fill in all 6 programs. To set a schedule please follow the steps below:
This function is available only in schedule mode (AUTO). If a new setpoint temperature will be set during the schedule – it will be maintained until next time interval starts according to a programmed schedule.
The temporary Override mode will be disabled when the new schedule will be set.
This function is available in scheduled and manual mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to the previous mode. To set this mode please follow steps below:
To turn off hourly temperature override mode before time’s up, press the + Hr button until a number of hours disappear from the display.
In this mode the setpoint temperature is automatically set to frost setpoint to prevent pipes from frosting. If the room temperature is lower than the frost setpoint, frost protection will be enabled. To set frost protection mode follow steps below:
The Frostpoint temperature can be reviewed by pressing the UP button once, but can only be changed in Installer Mode.
In this mode the “frost protection” temperature is maintained for a specific number of days. To set the holiday mode please follow steps below:
To turn off the Holiday Mode, hold the down the button for 3 seconds. The airplane icon should disappear from the display.
In sleep mode thermostat stay in frost protection temperature but it is switched off and doesn’t consume any energy and it is impossible to make an action until you activate the thermostat again. To activate/deactivate sleep mode follow steps below:
Temperatures below 10 °C are displayed without the leading ‘0’. Temperatures exceeding the measurable range will be indicated by ‘HI’ for temperatures above the upper limit, and ‘LO’ for temperatures below the lower limit, as shown in the images.
Battery voltage is checked every minute. When the battery voltage drops to a certain level, the Low-Battery warning
When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 seconds to change the batteries before losing your settings. To change batteries please follow steps below:
To enter installer parameters please follow the steps below. Please refer to the parameters table description before any changes. Use
DETAILED TABLE WITH ALL INSTALLER PARAMETERS:
dxx | Function | Parameter | Default value |
d01 | Temperature display accuracy | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/- 3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C – 17.0°C | 5.0°C |
d04 | Schedule type | 5/2 or 24 hr (7d) | 5/2 d |
DIP switches are used to set chosen control algorithm. They are under back cover of the thermostat (please refer to the picture below):
Type of control | TPI | Hysteresis |
How it works | When TPI is selected on DIP switch № 2, then DIP switch № 1 is functional. You can choose the Cycles Per Hour between a lower comfort level (6CPH) and a higher comfort level (9CPH). | When Span is selected on DIP switch № 2, then DIP switch № 1 is not functional. The SPAN value is set to ± 0.25°C. |
To RESET RT510 thermostat to it’s factory default settings please follow the steps below:
The RT510 thermostat requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the thermostat). There are no user-serviceable parts within the unit; any servicing or repairs could only be carried out by Salus Controls or their appointed agents.
Power supply | 2 x AA batteries |
Rating max | 3 (1) A |
Output signal | NO/COM/NC relay |
Setpoint temperature range | 5 – 35°C |
Display temperature accuracy | 0.1°C or 0.5°C |
Control algorithm | TPI or Hysteresis: ±0.25°C |
Communication | Wired |
Dimension [mm] | 120 x 96 x 27 |
SALUS CONTROLS warrants this product to be free from any defects in material or workmanship and to perform as specified for a period of five years from the date of installation. SALUS CONTROLS reserves the sole responsibility for breach of this warranty by repairing or replacing the defective product. This product includes software that matches the distributor’s identification at the time of sale. The manufacturer/distributor provides a guarantee covering all functions and specifics of the product in accordance with this marking. The distributor’s warranty does not cover the correct operation of the functions and features available as a result of a product software update.
The full warranty conditions are available at www.salus-controls.eu
PRODUCER:
Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science Park East Avenue, Shatin, New Territories, Hong Kong
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change the specification, design and materials of products listed in this brochure without prior notice.
Download Manual
SALUS RT510 Wired Programmable Thermostat User Manual
OTHER MANUALS
SALUS RT510 Wired Programmable Thermostat Quick Guide
SALUS RT510 Wired Programmable Thermostat Wiring Daigram
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…