RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allows us to use various operating modes – automatic (time schedules), manual, frost protection or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com
Safety Information Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.
RT510 Thermostat | RT510TX Thermostat | |
Thermostat supply | 2 x AA alkaline batteries | 2 x AA alkaline batteries |
Thermostat rating max | 3 (1) A | – |
Outputs | Voltage free NO / COM / NC terminals | – |
Temperature range | 5 – 35°C | 5 – 35°C |
Temperature accuracy | 0.1°C or 0.5°C | 0.1°C or 0.5°C |
Control algorithm | TPI or hysteresis ±0.25°C | TPI or hysteresis ±0.25°C |
Radio frequency | – | 868 MHz |
Dimension [mm] | 120x96x27 | 120x96x27 |
RXRT510 Receiver | |
Receiver supply | 230 V AC |
Receiver rating max | 16 (5) A |
Outputs | Voltage free NO / COM terminals |
Radio frequency | 868 MHz |
Dimension [mm] | 96x96x27 |
RT510 Terminals description
Terminal | Description |
1 – COM | Common Terminal |
2 – NC | Switched Live OFF |
3 – NO | Switched Live ON |
RXRT510 Receiver terminals description
Terminal | Description |
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
DIP Switch Settings
Control feature | TPI | Span |
Operation | When TPI is selected on | When Span is selec- |
DIP switch № 2, the DIP | ted on DIP switch № | |
switch № 1 is functional. | 2, the DIP switch № | |
You can choose the | 1 is not functional. | |
Cycles Per Hour between | The SPAN value is | |
a lower comfort level | set to ± 0.25°C – it is | |
(6CPH) and a higher | recommended to use | |
comfort level (9CPH). | with heating devices. |
RT510 Wiring diagram
RT510RF Wiring diagram
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
Programming – automatic mode
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). You have the option to choose between a 5-2 days programme or a daily one by using the parameter d04 from Installer mode.Programmed schedules should use all time periods.
Manual Mode and setting setpoint temperature
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
To turn off the Manual Mode press
Hourly temperature Override Mode (+Hr)
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
Turning off hourly temperature override mode before time’s up
Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed in Installer Mode in d03 parameter.
Sleep mode
When the sleep mode is activated, all thermostat functions are paused.
Holiday Mode
In this mode the “frost protection” temperature is maintained for a specific number of days.
To turn off the Holiday Mode, hold down
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
If you want to re-pair thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Next switch to the OFF position and again to ON position quickly. The red flashing LED will confirm entering the pairing mode.
Begin the pairing process
End the pairing process
Test the pairing process
If you purchased an RXRT510 or RT510TX and intend pairing with other devices in the 5×5 range, please refer to the Receiver Units manual or the relevant manuals available at www.salus-controls.eu
Installer mode
dxx | Function | Parametr | Default value |
d01 | Temperature display increments | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/- 3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C – 17.0°C | 5.0°C |
d04 | Programmer selection | 5/2 or 24 hr (7d) | 52 d |
Reset of the RT510 thermostat
Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.
Reset of the RT510TX thermostat
Remove the batteries without pressing any button. Wait 2 minutes and insert the batteries again. Your device will be restarted.
When you want to change the batteries your device will use the internal memory to back up your settings. You have 30 seconds to change the batteries before losing your settings.
Download Manual
SALUS RT510 Wired Programmable Thermostat Quick Guide
OTHER MANUALS
SALUS RT510 Wired Programmable Thermostat User Manual
SALUS RT510 Wired Programmable Thermostat Wiring Daigram
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…