DT500/DT500RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allows us to use various operating modes – automatic (time schedules), manual, frost protection or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat.. Place the batteries into the battery slot located under the cover (see the Battery replacement chapter on the back). Do not use rechargeable batteries
Product Compliance
This product complies with the essential requirements and other relevant provisions of Directives EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com
Safety Information
Use in accordance to national and EU regulations . Use the device as intended , keeping it in dry condition.Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU requlations
DT500 Thermostat | DT500RF Thermostat | |
Thermostat supply | 2 x AA alkaline batteries | 2 x AA alkaline batteries |
Thermostat rating max | 5 (3) A | – |
Outputs | Voltage free NC / NO / COM terminals | – |
Temperature range | 5 °C – 35 °C | 5 °C – 35 °C |
Temperature accuracy | 0.1 °C or 0.5 °C | 0.1 °C or 0.5 °C |
Control algorithm | ITLCSPAN ± 0.25 °C or ± 0.5 °C | ITLCSPAN ± 0.25 °C or ± 0.5 °C |
Radio frequency | – | 868 MHz |
Dimension [mm] | 120 x 90 x 29 | 120 x 90 x 29 |
DTRX5 Receiver | |
Receiver supply | 230 V AC |
Receiver rating max | 16 (5) A |
Outputs | Voltage free NC / NO / COM terminals |
Radio frequency | 868 MHz |
Dimension [mm] | 98 x 98 x 25.2 |
DT500 Thermostat Terminals description
Terminal | Description |
COM | Common Terminal |
NO | Switched Live ON |
NC | Switched Live OF |
DTRX5 Receiver Terminals description
Terminal | Description |
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Power Supply (230 V AC) |
DT500RF Thermostat Wiring Diagram.
Programming – automatic mode
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). To do this, firstly choose programming mode: “5-2” (business days + weekend) or “24h” (each day separately) using parameter d04 from Installer mode. Programmed schedules should use all time periods.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule – it will be maintained until next time interval starts according to programmed schedule.
Temporary Override mode will be disabled when new schedule will be set
Manual Mode and setting setpoint temperature
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
To turn off the Manual Mode press the button. Once the manual mode is off, the hand icon on the thermostat will disappear.
Hourly temperature Override Mode (+Hr)
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
Turning off hourly temperature override mode before time’s up
Temperature of the Frost Protection
Sleep Mode
When the sleep mode is activated, all thermostat functions are paused.
Deactivate the Sleep Mode
Holiday Mode
In this mode the “frost protection” temperature is maintained for a specific number of days.
To turn off the Holiday Mode, hold down
DT500RF Thermostat Pairing with the DTRX5 Receiver
Note: If you are using the DT600RF pack, the pairing between the thermostat and the receiver is already done. During the pairing process, please make sure the thermostat and the receiver are at least 1 meter from each other
Important note: The communication radius of the thermostat with the receiver is of maximum 100m, in open space. In built space, with various obstacles (eg walls, floors, metal structures, furniture elements), the communication radius will be significantly reduced. RF communication can be disrupted by local factors, such as GSM antennas, radio frequency devices or toys, or other equipment that produces electromagnetic interference. Receivers for the boiler must be powered from a stable voltage source, without frequent interruptions or voltage fluctuations (outside the standard
If you want to re-pair the devices with each other, follow the steps below
Test the pairing process
Installer Mode
dxx | Function | Parameter value | Default value |
d01 | Temperature display increments | 0.1 °C or 0.5 °C | 0.5 °C |
d02 | Temperature offset | +/- 3.0°C | 0.0 °C |
d03 | Frost protection setpoint temperature | 5.0 °C – 17.0 °C | 5.0 °C |
d04 | Programmer selection | 5/2 or 24hr (7d) | 5/2 d |
d05 | TPI or SPAN algorithm selection TPI = self-adaptive algorithmSPAN = hysteresis (fixed temperature deviation) | ITLC or SPAN | ITLC |
d06 | TPI or SPAN adjustment (if you selected SPAN in parameter d04, then parameter d05 will display the SPAN settings, the same applies to the TPI algorithm) | 6CP or 9CP /0.25 °C or 0.5 °C | 6CP / 0.5 °C |
To insert and replace the batteries, follow the steps below:
Reset of the DT500/DT500RF thermostat
Press and hold
SALUS
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice.
Download manuals:
SALUS DT500 Thermostat User Guide
OTHER MANUALS:
Salus DT500RF PROGRAMMABLE WIRELESS THERMOSTAT Product Data Sheet
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…