Salus

Salus AHTR3024 Digital Thermostat Installation Guide

Salus AHTR3024 Digital Thermostat

Contents of the box

Product Description

Thank you for purchasing the SALUS AHTR3024 Thermostat. This thermostat is a device that lets you customize the heating and cooling of your home as needed. The AHTR3024 device from SALUS Controls is a stylish and accurate digital room thermostat that is fitted with a  large easy-to-read LCD  screen and a one-touch button. You can now simply adjust your home temperature as desired in order to create a comfortable home environment. We hope you enjoy our product.

Product Compliance & Safety Information

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003.

Safety Information
Use in compliance with safety regulations. The unit is to be used for the control of room temperature inside the house.

Installation
This accessory must be fitted by a competent person, and installation must comply with the guidance, standards, and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.

Note: For changing the temperature display from ºC to ºF, go to Installer Mode Menu and change d00 to 1.

Mounting the Thermostat

Install the AHTR3024 digital room thermostat at roughly 1.5m or 4.92ft above floor level. It should be mounted in a location where the thermostat is easily accessible and away from direct sunlight. You can mount the thermostat directly on the wall or you can install it on top of a wall-box.

Terminal Connection

Note: You can wire the thermostat directly to the AKL08 wiring center or to an actuator (purchased separately).

Thermostat Icons

Button Functions

You can change the Modes by tapping the desired one. and position the box on the desired one.

Note: In Auto Mode the change in Manual Override Mode is temporary. This is indicated by the icon. When used as a stand-alone, the change is permanent.

Frost Protection

Note: All electrical installation work should be carried out by a suitably qualified electrician or another competent person.

Night Setback Function (NSB)

NSB Mode depends on the NSB wired connection.

  • 0V=NSB OFF
  • 24V=NSB ON

This function will be activated only when the device is running in Auto Mode.

If the thermostat receives an NSB signal then it will switch to If the NSB is turned off, the unit will function and You can manually set the thermostat on NSB by moving the box on the icon.

Note: The NSB function will be available only when you also have another device that can send an NSB signal (AHTR3024 thermostat, external clock, NSB switch or another clock thermostat).

Note: LCD backlight is activated by pressing any key.

Setting the Thermostat

Device No Function Valves Definition Default Value
d00 Select ºC/ºF 0 ºC 0
1 ºF

d01

Heating Control

0 PWM

0

1 On-Off: 0,5 ºC (+_0,25 ºC)

On-Off: 32,9 ºF (+_32,45 ºF)

2 On-Off: 1,0 ºC (+_0,5 ºC)

On-Off: 33.8 ºC (+_32,9 ºF)

d02 Room temp offset -3,0 ºC to +3,0 ºC

-26,6 ºF to +37,4 ºF

Offset room temp measuring error (in 0,5 ºC / 32,9 ºF) 0.0ºC / 32 ºF

d05

Cooling Control

1 On-Off: 0,5 ºC (+_0,25 ºC)

On-Off: 32,9 º F(+_32,45 ºF)

2

2 On-Off: 1,0 ºC (+_0,5 ºC)

On-Off: 33,8 ºC (+_32,9 ºF)

d07 Valve Protection 0 Disable 1
1 Enable
d08 Frost Setpoint 5.0 – 17.0 ºC

41 – 62.6 ºF

5.0ºC / 41 ºF
d12 Max. Heating Setpoint 5.0 – 35.0 ºC

41- 95 ºF

35ºC / 95 ºF
d13 Min. Cooling Setpoint 5.0 – 40.0 ºC

41 – 104 ºF

5.0ºC / 41 ºF
d18 Heating/CoolingMode 0 No Connection 0
1 Connection
d19 Cooling Blocked 0 Cooling Allowed 0
1 Cooling Disabled
d20 Selecting the number of actuators 0 1 to 5 actuators loading 0

Setting the Thermostat

Note: The d20 will help you to reduce the power outlet on the thermostat.

Setting the hysteresis
You can set the hysteresis by entering the Installer Mode, accessing d01, and after that selecting the desired value ( PWM / 0.5°C or 32.9ºF / 1.0°C or 33.8ºF). If your device controls the UFH we recommend using the PWM algorithm.

Heating and Cooling Selection
Manually
This mode will be indicated by the flashing icons
Press or change between modes.

Auto
The CO terminal needs to be connected using the same phase as the power supply. After that the heating and cooling functions will be done automatically In Installer Mode, d18 has to be set to 1 (default is 0), when the CO wire is connected.

Setting the Thermostat

Cooling blocked
When the thermostat is set on Cooling Disabled (d19–>1) it will block the cooling function for single rooms until the device receives the heating command. During the periods of Cooling Blocked, no special indicator will be displayed on the LCD screen. The cooling mode indicator will also be turned off.

Protection
When the room temperature is over the limit of 36°C(96.8ºF), all heating outputs will be turned off regardless of the control pattern and delay timers. When the room temperature is under the limit of 4°C(39.2ºF), all cooling outputs will be turned off regardless of the control pattern and delay timers.

Factory Reset

Heating/Cooling Mode

Temperature Mode Heating Cooling
Sunny 20.0 °C / 68.0 °F 20.0 °C / 68.0 °F
Moon 17.0 °C / 62.6 °F 26.0 °C / 78.8 °F
Frost (heat system) 5.0 °C / 41 °F –.-

 

Temperature Offset (TemperatureCalibration)

Technical Data

Model: AHTR3024
Voltage 24 VAC, +/-10 %, 50/60 Hz
Operating performance 24 V, 18 W
Temperature setback Adjustable
Temperature range 5°C – 35°C (41ºF – 95ºF)
Span +/-0,5°C (32,9ºF) OR +/-0,25°C (32,45ºF)
Storage temperature -20°C to +60°C (-4ºF to +140ºF)
Ambient temperature 0 °C up to 45 °C(32ºF up to 113ºF)
Degree of protection IP 30
Conformity according to FCC and IC
Housing material PC, V2
Color RAL 9010 pure white
Connection Screw terminal
Weight 125 g net / 170 g gross (4.40oz/5.99oz)
Puls-wide-modulation (PWM) Yes
Profile Modes 3 ( Sun, Moon, Automatic)
Heating and Cooling Yes, automatically Change Over

on the Wiring Centre

Parameter adjustment Yes, in Installer Mode
Dimensions 85mm*85mm*25mm( 3.34in*3.34in*0.98in)

Warranty

SALUS NA warrants that this product (AHTR3024) will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS NA’s sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.

Customer Name: ………………………………………………………………………………………………………………………………….
Customer Address: ……………………………………………………………………………………………………………………………..
……………………………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………… Post Code: ………………………………………………………………..
Tel No: ………………………………………………………….. Email: ……………………………………………………………………………
Engineers Company: ………………………………………………………………………………………………………………………….
Tel No: ……………………………………………………………. Email: …………………………………………………………………………
Instalation Date: …………………………………………………………………………………………………………………………………..
Engineers Name: …………………………………………………………………………………………………………………………………
Engineers Signature: ………………………………………………………………………………………………………………………….

SALUS North America is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change the specification, design, and materials of products listed in this brochure without prior notice For the PDF Installation guide please go to: www.salusna.com

SALUS NORTH AMERICA,
850 MAIN STREET, REDWOOD CITY, CA 94063
EMAIL: SALES@SALUSNA.COM
TEL: +1-650-360-1725

REFERENCE

Download Manual

Salus AHTR3024 Digital Thermostat Installation Guide

Other Manual

Salus AHTR3024 Digital Thermostat Product specification Guide

Salus AHTR3024 Digital Thermostat Installation Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago