Roth

Roth Softline Room Thermostat Installation Manuals

Roth Softline Room Thermostat

Installation

  • Push lightly on the snap lock with a finger or screwdriver (if mounted on the wall) to slide the backplate of the thermostat.
  • Insert batteries (included), be aware of +/- polarity.
  • It is possible to connect a floor sensor to the thermostat (floor sensor not incl.). Push gently on the terminals while you put the cable into the terminal. The sensor must be drawn in a tube and the tip placed directly beneath the top floor cover, in the middle between the floor heating pipes
  • Mount backplate on the wall (screws not incl.) thermostat slides onto the back plate
  • If you want to use the thermostat as a free-standing, the supplied foot can be mounted in the back plate before it’s mounted again
  • The thermostat can be connected to all Controllers in the Softline series. Pairing/registering is made the same way on all Controllers using the same buttons. On the pictures the panel of the Softline Controller, master is shown

Pairing/registering the thermostat to a zone (channel). All connections must be made to the Controller (pump, actuators and optionally potential free relay) before start-up. Please see controller manual for details. Attention! Do not press the buttons on the front of the thermostat whilst pushing the pairing button on the rear

Once the thermostat is connected to the Zone/Channel, the overview shows: –
Temperatures on the thermostat (setpoint 22,0°C, actual 25,0°C) , battery (99%), signal strenght (100% – must be at least 10%) and mode of operation (CON = continously). For more info on the display, see the controller manual. Repeat registration for other thermostats, by choosing one of the other zones (2 to 8) until required number of thermostas are connected.

Attention! If a thermostat is paired to the wrong zone, do not delete the thermostat. Pair the thermostat to the correct/new zone and the old pairing will be deleted.

If the thermostat has a floor sensor connected, this must also be paired/registered as shown below (picture 21, must be two quick presses).

In the overview, you can see both the thermostat (setpoint 22,0°C, actual 25,0°C) and the actual floor temperature (21,0°C). Repeat this for all other zones/channels (2 to 8) with a floor sensor.

Operation

  • Operation/setting of the floor sensor is carried out on the display of the Controller.
  • Floor sensor operation can be set up as either ”Floor protection” (standard) or ”Comfort” (min. Floor temp.).
  • Set sensor as ”Floor protection”. Choose operation mode and choose ”Floor protection”.
  • Set max. floor temperature to protect your floor.
  • Confim with ”Menu”.
  • Set sensor as ”Comfort”.
  • Choose operation mode and choose ”Comfort”.
  • Set min. floor temperature for your comfort level.
  • Confirm with ”Menu”. Min. temperature is set as described above.

Operation of thermostat

ROTH UK Ltd

REFERENCE:

DOWNLOAD MANUALS:

Roth Softline Room Thermostat Installation Manuals

Roth Softline Room Thermostat Installation Manuals

wpx_thermostats

Recent Posts

Free Money Online Casino No Deposit Canada

Free Money Online Casino No Deposit Canada However, and players have no control over it.…

1 week ago

Eureka Casino No Deposit Bonus Codes For Free Spins 2026

Eureka Casino No Deposit Bonus Codes For Free Spins 2026 Furthermore, and beginner-friendly as well.…

1 week ago

Top 10 Online Canada Casinos

Top 10 Online Canada Casinos Top 10 online canada casinos you can contact Easy Slots'…

1 week ago

2026 Canada Changes In Blackjack

2026 Canada Changes In Blackjack 2026 canada changes in blackjack an online casino reload bonus…

1 week ago

Mannheim Casino No Deposit Bonus Codes For Free Spins 2026

Mannheim Casino No Deposit Bonus Codes For Free Spins 2026 Don't miss out on this…

1 week ago

Slot Games For Real Money

Slot Games For Real Money I should start with a variety of gambling options, you…

1 week ago