Caution:
When the battery icon appears, replace the alkaline AAA batteries immediately to avoid damage to your HVAC system. Freezing or overheating could occur
Battery Door Information
Filter Change Reminder
The thermostat can be configured to remind you when the air filter needs to be changed. The filter change reminder can be adjusted to up to 2000 hours in 50 hour increments.
If the installer configured the thermostat to issue this reminder, FILTER will be displayed when it is time to change the air filter. When FILTER is displayed, you should change the air filter and reset the Filter Change Reminder by holding down the second button from the top left side of the thermostat for 3 seconds.
Set Time
Set temperature
Feature | Filter Change Reminder | Room Temperature Calibration | Minimum Compressor On Time | Compressor Short Cycle Delay | Cooling Differential | Heating Differential |
Adjustment Options |
The filter change reminder can be adjusted from OFF to 2000 hours in 50 hour increments. |
The room temperature display can be adjusted to read 3° above or below the factory calibrated temperature. | The minimum compressor run time can be adjusted from OFF to 3, 4, or 5 minutes. If 3, 4, or 5 is selected, the compressor will run for at least the selected time before turning off (although the fan may continue to run for a short time). |
The compressor short cycle delay setting can be removed by selecting OFF. |
The cooling differential setting is adjustable from 0.2°F to 2°F |
The heating differential setting is adjustable from 0.2°F to 2°F. |
Feature | Filter Change Reminder | Room Temperature Calibration | Minimum Compressor On-Time | Compressor Short Cycle Delay | Cooling Differential | Heating Differential |
Factory default settings | OFF | 0°F | OFF | On | 0.5°F | 0.4°F |
Feature Description |
This setting will flash FILT in the display after the elapsed run time to remind the user to change the filter. The OFF setting will disable this feature. |
This setting allows the installer to change the calibration of the room temperature display so that, for example, the thermostat would read 72°F instead of 70°F. |
The installer can select the minimum run time for the compressor to help protect the compressor from short-cycling. |
The compressor short cycle delay setting will not allow the compressor to be turned on for 5 minutes after it was last turned off in order to protect the compressor. | The cooling differential is factory preset at 0.5°. This means that whenever the room temperature heats by 0.5° full degree from the temperature setting, the cooling system will turn on. If the cooling system turns on too often, increase the temperature differential. | The heating differential is factory preset at 0.4°. This means that whenever the room temperature cools by 0.4° from the temperature setting, the heating system will turn on. If the heating system turns on too often, increase the temperature differential. |
LCD will show | Next Step
Prev Step Done | Next Step
Prev Step Done | Next Step
Prev Step Done | Next Step
Prev Step Done | Next Step
Prev Step Done | Next Step
Prev Step Done |
Note:
In many systems with no emergency heat relay, a jumper can be installed between E and W2.
Customer Service +1.800.304.6563 Technical Service +1.800.445.8299 HVACCustomerService@robertshaw.com
www.robertshaw.com • 352-00301-001352-00310-001 Rev. B
© 2021 Robertshaw Controls Company.
Robertshaw® is a trademark of Robertshaw Controls Company.
DOWNLOAD MANUALS
Robertshaw RS8210 Non-Programmable Thermostat Operation Manual
other manuals:
Robertshaw RS8210 Non-Programmable Thermostat Installation Manual
Robertshaw RS8210 Non-Programmable Thermostat product Specifications Guide
Robertshaw RS8210 Non-Programmable Thermostat Operation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…