Robertshaw

Robertshaw RS8210 Non-Programmable Thermostat Operation Manual

Robertshaw RS8210 Non-Programmable Thermostat

THERMOSTAT OPERATION

  • LCD Screen
  • Fan Switch
  • System Switch
  • Temperature Set-Point
  • Buttons User Buttons
  1. LCD Screen
    See page 4 for details about this display readout.
  2. Fan Switch
    Select ON or AUTO. ON will run the fan continuously. AUTO will cycle the fan on only when the heating or cooling system is running.
  3. System Switch
    Selects the HEAT or COOL for your HVAC system. Selecting HEAT turns on the heat mode. Selecting COOL turns on the cool mode. Selecting OFF turns both heating and cooling off. Selecting EMH (for heat pumps with auxiliary heat) will lock out the compressor and control emergency/auxiliary heat.
  4. Temperature Set-Point
    Buttons Press the to the desired temperature.
  5. User Buttons
    Use these buttons to set up programming options.

THERMOSTAT QUICK REFERENCE

Caution:
When the battery icon appears, replace the alkaline AAA batteries immediately to avoid damage to your HVAC system. Freezing or overheating could occur

Battery Door Information

Filter Change Reminder
The thermostat can be configured to remind you when the air filter needs to be changed. The filter change reminder can be adjusted to up to 2000 hours in 50 hour increments.
If the installer configured the thermostat to issue this reminder, FILTER will be displayed when it is time to change the air filter. When FILTER is displayed, you should change the air filter and reset the Filter Change Reminder by holding down the second button from the top left side of the thermostat for 3 seconds.

Set Time

  1. Press the MENU button.
  2. Press SET TIME.
  3. Day of the week will be flashing. Use to select the current day of the week.
  4. Press NEXT STEP.
  5. The current hour will be flashing. Use to select the current hour. Note the correct a.m. or p.m. indicator is selected.
  6. Press NEXT STEP.
  7. The minutes will be flashing. Use to select the current minutes.
  8. Press DONE when completed.

Set temperature

  1. Use to select set temperature.

INSTALLER SETUP MENU

  1. Press MENU.
  2. Press and hold TECH SET for 3 seconds.
  3. Configure the installer options as desired using the table below.
  4. Use and to change settings and the NEW STEP or PREV STEP to move from one option to another.
    Note: Only press DONE when you want to exit the Installer Setup Options.

Feature

Filter Change Reminder

Room Temperature Calibration Minimum Compressor On Time Compressor Short Cycle Delay

Cooling Differential

Heating Differential

 

 

 

 

 

 

Adjustment Options

 

 

The filter change reminder can be adjusted from OFF to 2000 hours

in 50 hour increments.

 

 

The room temperature display can be adjusted to read 3°

above or below the factory calibrated temperature.

The minimum compressor run time can be adjusted from

OFF to 3, 4, or 5

minutes. If 3, 4, or 5 is selected, the compressor will run for at least the selected time before turning off (although the fan may continue to

run for a short time).

 

 

The compressor short cycle delay setting can be removed by selecting OFF.

 

 

 

The cooling differential setting is adjustable from 0.2°F to 2°F

 

 

 

The heating differential setting is adjustable from 0.2°F to 2°F.

Feature

Filter Change Reminder Room Temperature Calibration Minimum Compressor On-Time Compressor Short Cycle Delay

Cooling Differential

Heating Differential

Factory default settings OFF 0°F OFF On 0.5°F 0.4°F

 

 

 

 

 

 

 

Feature Description

 

 

 

This setting will flash FILT in the display after the elapsed run time to remind the user to change the filter.

The OFF setting will disable this feature.

 

 

This setting allows the installer to change the calibration of the room temperature

display so that, for example, the thermostat

would read 72°F instead of 70°F.

 

 

 

 

The installer can select the minimum run time for the compressor to help protect the compressor from

short-cycling.

 

 

 

The compressor short cycle delay setting

will not allow the compressor to be turned on for 5 minutes after it was last turned off in order to protect the compressor.

The cooling differential is factory preset at 0.5°. This means that whenever the room temperature heats by 0.5°

full degree from the temperature setting, the cooling system will turn on.

If the cooling system turns on too often, increase the temperature

differential.

The heating differential is factory preset at 0.4°. This means that whenever the room temperature cools by

0.4° from the temperature setting, the heating system will turn on. If the heating system turns on too often, increase the temperature differential.

LCD will show

Next Step

 

 

 

Prev Step Done

Next Step

 

 

 

Prev Step Done

Next Step

 

 

 

Prev Step Done

Next Step

 

 

 

Prev Step Done

Next Step

 

 

 

Prev Step Done

Next Step

 

 

 

Prev Step Done

  • FILTER Setting: Display SE Fl, flashing 1000 (the default value 1000 hours), and select from 50-2000 hours.
  • Temperature Calibration: Display CAL and flash 0°F (the default value 0), select from -3-3°F.
  • The minimum compressor on time: Display AN ON and flashing OFF (default setting), select from OFF, 3, 4 or 5 minutes.
  • Compressor Delay Time Setting: Display CO OF and flashing ON (default setting), select from ON or OFF.
  • Cooling Differential Setting: Display df CO and flashing 0.6, choose from 0.2-2.0 (factory default setting: 0.6°F).
  • Heating Differential Setting: Display df HE and flashing 0.5, choose from 0.2-2.0 (factory default setting: 0.5°F).
  • °F/°C Selection: Setting F (Fahrenheit) or C (Celsius).
  • 24H/12H Selection: Setting the 24-hour or 12-hour time format. ELEC/GAS Selection: Select the ELEC or GAS.

TERMINAL DESIGNATIONS

  • W2………..Auxiliary heat relay
  • Y…………..Compressor relay
  • G…………..Fan relay
  • O………….. Heat pump reversing valve energized in cooling
  • RH………..24VAC Power
  • C…………..Common wire (if applicable)
  • B…………..Heat pump reversing valve energized in heating
  • E…………..Emergency heat relay

Note:
In many systems with no emergency heat relay, a jumper can be installed between E and W2.

Customer Service +1.800.304.6563 Technical Service +1.800.445.8299 HVACCustomerService@robertshaw.com
www.robertshaw.com • 352-00301-001352-00310-001 Rev. B
© 2021 Robertshaw Controls Company.
Robertshaw® is a trademark of Robertshaw Controls Company.

Reference

DOWNLOAD MANUALS

Robertshaw RS8210 Non-Programmable Thermostat Operation Manual

other manuals:

Robertshaw RS8210 Non-Programmable Thermostat Installation Manual

Robertshaw RS8210 Non-Programmable Thermostat product Specifications Guide

Robertshaw RS8210 Non-Programmable Thermostat Operation Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago