As an Energy Star partner, Maple Chase has determined that this thermostat product meets the Energy Star guidelines for energy efficiency.
Replacing Existing Thermostat
Old Label | New Label | Description |
R, V-VR or VR-R | R | 24 VAC |
Y, Y1 or M | Y1 | 1st Stage Cooling Circuit |
O or R | O | Reversing Valve (Cooling Mode) |
B | B | Reversing Valve (Heating Mode) |
G or F | G | Fan Contactor Circuit |
Y2 | Y2 | 2nd Stage Cooling Circuit |
W2 or W-U | W2 | 2nd Stage Heating Circuit |
W1 | W1 | 1st Stage Heating Circuit |
C, X or B | C | 24 VAC, Transformer Common Side |
NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON THE INSIDE WALL, 4-5 FEET ABOVE THE FLOOR. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM-GENERATING FIX-TURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION.
IMPORTANT: THIS THERMOSTAT IS COMPATIBLE WITH 100% LOCKOUT SYSTEMS. TO RESET THE SYSTEM, TURN THE THERMOSTAT TO THE OFF POSITION FOR AT LEAST 60 SECONDS.
Set Time of Day, Day of Week, Temperature Differential, Residual Cooling
To change Residual Cooling
NOTE: THE RESIDUAL COOL FEATURE WILL KEEP THE SYSTEM FAN ON FOR AN ADDITIONAL 30, 60, OR 90 SECONDS AFTER THE COMPRESSOR CYCLES OFF. THE RESIDUAL COOL FEATURE CAN ONLY BE SET IN THE COOL MODE. Changing Fahrenheit (F) to Celsius (C)
NOTE: QuickSet™ will program all 7 days of the week with the same program.
Begin Programmed Operation
NOTE: WHILE IN THE COOL MODE ONCE THE THERMOSTAT TURNS THE SYSTEM OFF, A BUILT-IN DELAY KEEPS THE COMPRESSOR FROM TURNING ON FOR ABOUT 5 MINUTES. THIS PROTECTS THE COMPRESSOR. NO ADDITIONAL TIME DELAY RELAY (DELAY ON BREAK) IS NECESSARY. TO OVERRIDE THE 5-MINUTE DELAY FOR INSTALLATION, PRESS RESET. THIS WILL ERASE THE DELAY AS WELL AS ALL PROGRAMMING.
EER™ allows your system to operate at peak efficiency for optimal energy savings. EER™ looks up to 2 hours prior to the end of a set-back period to begin monitoring system performance and determine the most efficient time to turn on your system. During this period, the auxiliary stages of heating or cooling will be locked out. Only the most efficient stages will be utilized. At 20 minutes prior to the upcoming setpoint time, the auxiliary stages will be available to achieve temperature setpoint if required.
Temporary Program Override
To temporarily increase or decrease the temperature
Press
The Thermostat will automatically return to the program at the next scheduled setting change or after 4 hours.
To Reset the thermostat to factory pre-programmed conditions, press the reset button located directly to the right of the display.
To Test Thermostat
WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.
CAUTION: DO NOT SWITCH THE SYSTEM TO COOL IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY.
The LED indicator illuminates during a call for second-stage heating or cooling. The auxiliary stages are used to maintain comfort during extreme in weather conditions. If the LED is illuminated too frequently during periods of moderate temperature, check the differential settings (page 5). 9
Wiring Diagrams
The following is just a sample of the most common types of HVAC systems. Refer to your system’s installation manual for wiring information.
Maple Chase Company warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This warranty does not cover batteries, damage caused by batteries, or damage resulting from improper installation, alteration, misuse or abuse of the thermostat occurring after the date of purchase. Maple Chase Company agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period, postage prepaid, with proof of the date of purchase. The cost of thermostat removal or reinstallation is not the responsibility of Maple Chase Company.
Repair or replacement as provided under this warranty is the exclusive remedy of the consumer. Maple Chase Company shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, or under any other theory of liability. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Maple Chase Company 2820 Thatcher Road Downers Grove, Illinois 60515 United States of America
Download Manual: Robertshaw C9615 DIGITAL PROGRAMMABLE Thermostat Quick Start Installation and Programming
Robertshaw C9615 DIGITAL PROGRAMMABLE Thermostat Quick Start Installation and Programming
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…