WARNING:
Replacing Existing Thermostat
Old Terminal | New Label | Description |
M,R,Rh,R5 or 5 | R | Heat transformer, hot side |
H,W, or 4 | W | Heating control |
F or G | G | Fan control relay |
If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the garbage. Contact your local waste management authority for instructions regarding proper disposal of the thermostat. If you have any questions, call Robertshaw technical support at 1-800-445-8299.
TERMINAL LEGEND – 9405 | |||
TERM | EQUIPMENT TO CONNECT | REQ? | TERMINAL FUNCTION |
R | 24VAC hot connection | Yes | For input of 24VAC hot side of heat transformer |
W | Heat connection | Yes* | Energizes on a call for heating |
G | Indoor fan connection | Yes | Energizes with W terminal or with FAN option switched to the ON position |
Testing the Thermostat
Settings
Temperature
Heating: The default temperature for heating is 70°F (21°C). To change the default setpoint, put the system switch in HEAT and press the or button to adjust the temperature setting up or down. The display will show SET. The display will return to the current room temperature three seconds after the last input and the new setpoint will be saved
Temperature Differential
The temperature differential is factory set at 1.0°F (.5°C). This means that whenever the room temperature changes by one degree Fahrenheit from the temperature setting, the system will turn on. If the system turns on too often, increase the temperature differential
Changing Fahrenheit (°F) to Celsius (°C), and the Temperature Differential
Backlit Display
This thermostat is equipped with a backlight to make nighttime temperature adjustments quick and easy. Press the button to activate the backlight. The backlight will turn off after about 5 seconds of inactivity.
Reset
To reset the thermostat press the RESET button located at the lower left corner of the base
Symptom | Remedy |
Thermostat does not turn on system. | Check wiring (see Installation section). |
Thermostat turns system on and off too frequently. | Increase temperature differential (see Changing the Temperature Differential section). |
Display is blank, flashing or constant LOW BATT. | Replace batteries. |
System fan does not operate properly. | Move fan option switch to either gas or electric, to match system (see Installation section). |
Thermostat does not display proper room temperature. | Check F/C (Fahrenheit/Celsius) setting. See Changing Fahrenheit (F) to Celsius (C). |
Two Year Limited Warranty
Maple Chase warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of two (2) years from date of purchase. This warranty and our liability does not apply to batteries or merchandise that has been damaged by misuse, neglect, mishandling, alterations, improper installation, or use in a way other than in accordance with Maple Chase recommendations and instructions. Maple Chase agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period, postage prepaid, with proof of the date of purchase. Cost of thermostat removal or reinstallation is not the responsibility of Maple Chase. Repair or replacement as provided under this warranty is the exclusive remedy of the consumer. Maple Chase shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, or under any other theory of liability. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For warranty returns, send thermostat, shipping prepaid to:
If problems with thermostat cannot be resolved, call:
DOWNLOAD MANUAL
Robertshaw 9405 Non-Programmable Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…