Robertshaw 8406 NON-PROGRAMMABLE Thermostat User Manual

Robertshaw 8406 NON-PROGRAMMABLE Thermostat

Application

The Robertshaw 8406 is a single-stage thermostat designed to control 24 VAC cooling systems.

Features

  • Low battery indicator
  • Large backlit display
  • Adjustable temperature differential: 1°F to 3.0°F (0.5°C to 1.5°C)
  • Compressor short cycle protection
  • Accuracy within ±1°
  • Zone system compatible as a master thermostat
  • Permanent memory retention
  • Fahrenheit/Celsius display option
  • Adjustable from 45°F to 90°F (7°C – 32°C)
  • Quick wire terminal block

WARNING

  • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat.
  • Read all the information in this manual before installing this thermostat.
  • DO NOT CONNECT TO 120 VAC. This is a 24 VAC low-voltage thermostat. Do not install on voltages higher than 30 VAC.
  • All wiring must conform to local and national building and electrical codes and ordinances.
  • Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty.
  • Do not connect ground to any terminal in this unit.

Recycling Thermostat

If this thermostat REPLACES a thermostat that contains mercury, DO NOT discard the old thermostat in the regular trash. Mercury is harmful to humans and the environment. For this reason, do not open, break, or crush the mercury cell. If mercury leaks from a damaged cell, DO NOT touch or handle mercury with bare hands. Use protective, non-absorbent gloves to place mercury into a sealable container. Fill the container with sand or another absorbent material and seal the container completely. Return the mercury or mercury products, in a sealed container, to Invensys Controls Americas or a local recycling center for proper disposal. If you have any questions, call Robertshaw technical support at 1-800-445-8299.Invensys Controls Americas 28C Leigh Fisher Blvd. El Paso, TX 79906 Attn: Mercury Recycling Center

Step 1: Replacing Existing Thermostat
Wiring Table

Old Terminal New Label Description
M,W,Rh,R5 or 5 Rh Heat transformer, hot side
V or Rc Rc Cool transformer, hot side
Y or Y6 Y1 Cooling control
F or G G Fan control relay
  1. Turn off power to heating and cooling system.
  2. Remove cover from old thermostat to expose wires (Figure 1).
  3. Disconnect wires one at a time from existing terminals. Use enclosed labels to mark existing wires. Refer to cross references in the Wiring Table if existing wiring does not directly match the labels.
  4. Remove existing thermostat base from wall.

Step 2: Installing Model 8406 Thermostat
NOTE:
FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON INSIDE WALL, FIVE FEET ABOVE THE FLOOR. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE LOCATIONS WILL AFFECT THERMOSTAT OPERATION.

  1. Turn power off to the heating and cooling systems.
  2. Place OFF-COOL in OFF position (Figure 2).
  3. Place AUTO-ON switch into AUTO position (Figure 2).
  4. Remove the cover using a coin or screwdriver (Figure 3). Set aside.
  5. Place thermostat against the wall at desired location. Make sure wires will feed through opening (Figure 4) on base of thermostat.
  6. Mark placement of mounting holes (Figure 4). Set base aside.
  7. If mounting on drywall, tap plastic anchors into wall.
    NOTE: Enclosed plastic anchors do not require a drilled hole for drywall.
  8. If mounting on a surface other than drywall, drill the marked holes using a 3/16″ (5mm) drill bit.
  9. Align base with plastic anchors and feed wires through opening.
  10. Secure base to wall with supplied screws. NOTE: The thermostat will mount horizontally on a single gang junction box.
  11. Strip end of wires 5/16” (8mm) if needed.
  12. Terminal screws are already loose and ready for wire insertion. Insert wires into terminal strip (Figure 4) matching the label to the corresponding terminal (see Wiring Diagrams). Tighten screws.

Wiring Diagrams

COOL ONLY 2-WIRE
SINGLE TRANSFORMER

TERMINAL LEGEND – 8406
TERM EQUIPMENT TO CONNECT REQ? TERMINAL FUNCTION
Rh 24VAC hot connection Yes For input of 24VAC hot side of heat transformer
Rc 24VAC hot connection Yes For input of 24VAC hot side of cool transformer
Y1 Compressor Connection Yes* Energizes on a call for cooling
G Indoor fan connection Yes Energizes with Y1 & W1 terminals or with FAN option switched to the ON position

  • Make sure wire connections are secure.
  • Push excess wire back through opening.
  • Set the Electric/Gas switch to ELEC (Figure 5).
  • Install two AA Energizer® brand batteries or equivalent into battery compartment as shown (Figure 5).
  • Replace thermostat cover by snapping into place.

Step 3: Testing the Thermostat
WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.

CAUTION: DO NOT SWITCH SYSTEM TO COOL OR LEAVE IN COOL MODE IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY.

  1. Place the OFF-COOL switch into the COOL position. The will be displayed.
  2. Press the button until the temperature setting is at least 3 degrees below the room temper-ature. The air conditioning system should turn on within a few seconds.
  3. Put the OFF-COOL switch into the OFF position. The air conditioning system should turn off.
  4. Put the OFF-COOL switch into the OFF position. The air conditioning system should turn off.AUTO-ON switch into the ON  position. The blower fan should turn on. The display will show a .
  5. Put the AUTO-ON switch into the AUTO position. The blower fan should turn off.

Step 4: Customizing the Thermostat

Settings System

  • System
    Cool: The thermostat controls the cooling.
    Off: The heating and cooling systems are off.
  • Fan
    Auto: Equipment controls the fan.
    On: The fan operates continuously.

Temperature Differential
The temperature differential is factory set at 1.0°F (.5°C). This means that whenever the room temperature changes by one degree Fahrenheit from the temperature setting, the system will turn on. If the system turns on too often, increase the temperature differential

Changing Fahrenheit (°F) to Celsius (°C), the Temperature Differential, and the Filter Monitor

  1. The thermostat is preset to display the temperature in degrees Fahrenheit (US models) or degrees Celsius (Canadian models). The temperature display can be changed. Press and hold both the and buttons for three seconds. The display will flash either an F or C. Release buttons. Press the or button to switch the display.
  2. Wait five seconds or press and the display will switch to the differential setting.
  3. The display will read diFF. The temperature differential is factory set at 1.0°F (0.5°C). Press the or button to adjust the differential up or down.
  4. Wait five seconds press and the display will switch to the filter monitor setting.
  5. CHECK FILTER and the length of hours for the filter monitor will be displayed.
  6. Use the or to adjust the filter timer from 0 (OFF) to 9900 hours.
    NOTE: The filter timer is based on equipment run time. Select the length of time based on the recommended service interval for your filter.
  7. Press the to return to normal operation

Check Filter Reset

Once the filter timer has expired, the CHECK FILTER will turn on and stay on. To clear the message and reset the timer:

  1. Press the and buttons and hold for 3 seconds. CLr will appear in the time display.
  2. Press any key to clear the message. The display will transition to the temperature scale display as described in the previous section.
  3. No further input is needed. Within a few seconds, the display will return to normal operating mode.

 Backlit Display
This thermostat is equipped with a backlight to make nighttime temperature adjustments quick and easy. Press the button to activate the backlight. The backlight will turn off after about 10 seconds of inactivity.

 Reset
To reset the thermostat press the RESET button located above the upper left corner of the display.

Step 5: Troubleshooting

Symptom Remedy
Thermostat does not turn on system. Check wiring (see Installation

section).

Thermostat turns system on and off too frequently. Increase temperature differential (see Changing the Temperature Differential section).
Display is blank, flashing or constant LO BATT. Replace batteries.
Thermostat does not display proper room temperature. Check F/C (Fahrenheit/Celsius) setting. See Changing Fahrenheit

(F) to Celsius (C).

Note: Although the thermostat has a low battery indicator, replace the batteries once a year to prevent leakage and to prevent the thermostat and heat/cooling system from shutting down due to a lack of battery power in the thermostat.
If problems with the thermostat cannot be resolved, call: Technical Support: at (800) 445-8299
Monday-Friday 7:30 AM – 5:30 PM CST
For after-hours service, a 24-hour automated helpline is available.

Two-Year Limited Warranty

Invensys Controls Americas warrants to the original contractor installer, or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of two (2) years from the date of purchase. This warranty and our liability do not apply to batteries or merchandise that has been damaged by misuse, neglect, mishandling, alterations, improper installation, or use in a way other than in accordance with Invensys Controls America’s recommendations and instructions.

Invensys Controls Americas agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period, postage prepaid, with proof of the date of purchase. The cost of thermostat removal or reinstallation is not the responsibility of Invensys Controls Americas.

Repair or replacement as provided under this warranty is the exclusive remedy of the consumer. Invensys Controls Americas shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, or under any other theory of liability. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty.

Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For warranty returns, send thermostat, shipping prepaid to:
Invensys Controls Americas
Warranty Claims Department 515 S.
Promenade Corona, CA 92879-1736

Controls Americas
191 E. North Avenue
Carol Stream, Illinois 60188
United States of America

Reference:

Download Manual:

Robertshaw 8406 NON-PROGRAMMABLE Thermostat User Manual

Robertshaw 8406 NON-PROGRAMMABLE Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago