Please take a moment to try out your touch screen itself.
To select a function on the touch screen, place your finger on the main temp display and give a short firm push. Try a “tap” of the finger or stylus. Your input must last long enough for the system to determine it is not an accidental ‘bump’.
Using the stylus is more comfortable for some users. Again allow the system enough time to recognize your inputs. When you are comfortable with touch inputs, proceed. Statement of use: The 6036 can be used with millivolt, 24VAC, single and 2 stage conventional systems, gas/oil/electric heat, 1 stage heat pumps, 2 stage heat pumps, zoned hot water (2 or 3 wire), zoned forced air, single and 2 stage cooling and hybrid systems.
Basic Screens
The MODE SWITCH of the 6036 must be in the HEAT or the COOL position to access all control functions. The 6036 Thermostat has 3 basic screens.
The HOME screen is displayed when unit is operating your system.
Touching the
HOME screen
MENU screen
PROGRAM screen
Displayed when the PROGRAM button is pressed.
Note: The Mode Switch must be in HEAT or COOL mode to configure.
Press MENU to configure the thermostat (from HOME screen).
Set day of the week
Touch the Day of the week area to cycle through the days of the week to select the current day.
Set time of day
Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting.
Set oC -oF display
Touch the oF and it will toggle to oC.
Set audible chirp
Touch the the musical note icon to select the chirp or no chirp.
EPA
Touch and hold for 4 sec to return to EPA Energy-Star program
Return HOME by touching the home icon.
This Thermostat comes preprogrammed with an Energy-StarTM approved program. This program is recommended by the EPA for energy efficiency.
We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not fit your needs you can always input a custom program.
EPA HEAT MORN 6:00am All Days 70oF | DAY 8:00am 62oF | EVEN 6:00pm 70oF | NITE 10:00pm 62oF | COOL | MORN 6:00am | DAY 8:00am | EVEN 6:00pm | NITE 10:00pm |
All Days | 78oF | 85oF | 78oF | 82oF |
NOTE: 60 Second Rule-During programming, if a button is not pushed in 60 seconds, the unit will return to the home screen. Everything you have changed while programming will automatically be saved.
Select the time of day
Touch the Time of Day arrows to move the time selection forward or backward until it displays the desired time. Touch and hold for faster time set.
Select the desired temperature
Return HOME by touching the home icon.
To program for cooling
Select COOL with the Heat/Cool MODE switch and repeat the above procedure.
MANUAL override screen
Note: The Mode Switch must be in HEAT or COOL mode to override.
Temporary OVERRIDE
HOLD
Swing
Swing setting determines the temperature difference in degrees from ON to OFF that the thermostat will command the HVAC system to run. With the MODE switch in HEAT or COOL, press the MENU button. Touch the SWING icon and the current setting of temp swing is shown on the display (default at .5o ).
To change the swing factor, touch the left or right arrows.
The furnace will cycle more at the lower numbers as it tries to maintain your temp.
Low Battery
When the batteries are low, the battery icon will flash. The two AAA Batteries in the unit need to be replaced. In some installations your heater system will stop functioning when the thermostat loses power. Replace batteries as soon as you see this warning. The thermostat programs will remain for 60 seconds while the batteries are changed.
Do not take longer than 30 sec to change the batteries in your unit or you will lose all custom settings and all programming. Only the EPA Energy-StarTM program will remain. Once the batteries are replaced, the system will return to normal in 2 seconds.
Lock
Allows you to to prevent any changes in custom settings. To Lock Level1, touch the LOCK icon on the MENU screen for 3 sec.Level1 allows temporary target adjustments but no program changes To Lock Level2, touch LOCK icon for 2 sec. Level2 allows no changes. To unlock, Touch the locked icon for 2 sec
The thermostat can display time in 12 or 24 hour formats. At the HOME screen touch the time to toggle from 12 to 24 hr display.
Filter Timer
The 6036 has a feature that keeps track of actual furnace run time and reminds you to periodically replace your system’s air filter.
If you have a heat pump with Auxiliary heat, the new sequential staging will give you faster recovery from set backs. The thermostat can be configured for Electric aux or gas/oil aux heat (see installation). If the heat pump cannot maintain your desired room temperature, the new system allows the Aux heat to help maintain your heat all the way to your desired room temperature.
When using a heat pump with Auxiliary heat, if the heat pump is not working, you can move the large jumper 3 from B
(lower) HEAT PUMP position to the A (upper) AUX ONLY position (reset is not necessary). The Auxiliary heat will then be your only source of heat. When the heat pump is again operational, be sure to change jumper 3 back to the B position as the Auxiliary heat is more expensive than the heat pump.
6036 Features
This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can be easily be set on the large touch screen with the UP/DOWN arrows. A minimum 4 minute off time protects heating and cooling systems from damage.
This thermostat uses a new technique called sequential staging for more comfort with faster reaction to requested temperature changes.
NOTE: Your thermostat comes from the factory calibrated to + or – 1oF actual temperature. It is an accurate instrument. If you want your thermostat to
display the same temperature as another thermometer in your home, you can adjust it. Maximum calibration is +/-6o .
To change the calibration:
With the switch MODE in HEAT or COOL.
Press the MENU button.
Press the Temp Up/Temp Down arrows to adjust the temperature reading. CALIBRATE DISPLAY ON will appear.
Press HOME to save the new setting.
Customer Support: 877-505-2353 or
Visit our website www.ritetemp-thermostats.com Printed in China
Download manual:
Ritetemp 6036 Touch Screen thermostat Operational Manual
OTHER MANUALS:
Ritetemp 6036 Touch Sceen thermostat Installational Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…