WARNING Follow Installation Instructions carefully. Disconnect Power to the Heater/Air Conditioner before removing the old thermostat and installing the new thermostat.
Remove and Replace the old thermostat
To install the thermostat properly, please follow these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.
Small flat blade screwdriver, Phillips screwdriver, wire cutters and wire strippers.
To remove the thermostat backplate:
Gently separate the display from the base by pulling from the center.
IMPORTANT: This thermostat requires both R (24 VAC Return) and C (24 VAC Common) be connected to the backplate terminals.
Ensure which switch is correct for your system. Dip switches are located on the back of the thermostat.
For Heat Pump Only
When the GAS/ELEC or HEATPUMP dip switch is configured for HEATPUMP, this dip switch (O or B) must be set to control the appropriate reversing valve. If O is chosen, the W1/O/B terminal will energize in cooling. If B is chosen, the W1/O/B terminal will energize in heating.
This dip switch configures the thermostat to control a conventional gas/electric system or a heat pump. If your system is anything other than a heat pump, leave this switch set for GAS/ELEC.
Conventional Heating and Cooling Systems
Heat Pump Systems
Setup Step Table
See User Manual for steps 1 – 8
FD = Factory Default Setting
Step# Description | Pg# | Range | Df | |
1 | Prog Mode | Non, 1 Day, 5/2 Day, 7 Day | 7 | |
2 | Available Modes | Heat/Cool/Auto/Off, Heat/Cool /Off, Heat/Off, Cool/Off | Heat/Cool /Auto/Off | |
3 | Backlight | On, Off | Off | |
4 | Backlight Level | Off thru 7 levels of brightness | Level 5 | |
5 | Night Dimmer | On/Off | Off | |
6 | Night Dimmer Brightness | Off thru 7 levels of brightness | 2 (20%) | |
7 | Night Dimmer Start Time | 12A-12A | 8:00P | |
8 | Night Dimmer Stop Time | 12A-12A | 6:00A | |
9 | Current Service Filter Runtime Hours | 0-1999 Hours | 0 | |
10 | Current Service Filter Calendar Days | 0-720 Days | 0 | |
11 | Current UV Lamp Calendar Days | 0-720 Days | 0 | |
12 | Set Service Filter Runtime Hours | 0-1950 hours | 0 | |
13 | Set Service Filter Calendar Days | 0-720 Days | 0 | |
14 | Set UV Lamp Calendar Days | 0-720 Days | 0 | |
15 | Language | English, Espanol, Francais | English | |
16 | Scrolling Method | “L-R Slow, L-R Fast, Word L-R Slow, Word L-R Fast, Whole Word L Slow, Whole Word R Slow, Whole Word Ctr. Fast, Whole Word Ctr. Slow” | “Whole Words Center Fast” | |
17 | Cycles Per Hour | No Limit, 2, 3, 4, 5, 6 | 6 | |
18 | Compressor Minimum Off Minutes | 0, 3, 5 Minutes | 5 | |
19 | Min. Heat/Cool Setpoint Difference | 0 – 6 Degrees | 2 | |
20 | Number of Heat Stages | 0 – 3 | 2 | |
21 | Number of Cool Stages | 0 – 2 | 1 | |
22 | Number of Aux Stages | 0, 1, 2 | 0 | |
23 | 1st Stage Deadband | 1 – 6 Degrees | 2 | |
24 | F/C | Fahrenheit (F), Celsius (C) | F | |
25 | Dry Contact Polarity | Open, Closed | Open | |
26 | Dry Contact Use | Condensate, Vacation, FDD | Vacation | |
27 | ProStat+ Web Portal | On, Off | On | |
28 | Local API | On, Off | Off | |
29 | ADR | On, Off | On | |
30 | Price Dependant Action | Observe Setpoint Offset, Observe Static Setpoints | Observe set- point offsets |
Step# Description | Pg# | Range | Df | |
31 | Event Max Cool Setpoint | 65 – 90 | 90 | |
32 | Event Min Heat Setpoint | 50 – 85 | 50 | |
33 | Static Cool Setpoint | 65 – 85 | 82 | |
34 | Static Heat Setpoint | 65 – 85 | 60 | |
35 | Cool Setpoint Offset | 1 to 10 | 4 | |
36 | Heat Setpoint Offset | -1 to -10 | -4 | |
37 | Press Fan To Clear All Messages |
How to Change Settings in the Setup Screens
To enter Advanced Setup, press the SETUP button, then press MODE. Use the WARMER or COOLER buttons to adjust the value of your selection. Press MODE to advance to the next setup step. Press SETUP again to leave the setup screens.
These setup steps allow the user to monitor equipment runtimes and program service alerts. Service alerts are displayed in the scrolling marquee.
Press and hold FAN to clear service alert messages from the scrolling marquee.
Current Service Filter Runtime Hours (Setup Step 9)
This counter keeps track of the number of hours of fan runtime in the Heating mode, Cooling mode, and in stand alone Fan operation. Press FAN to reset.
Current Service Filter Calendar Days (Setup Step 10)
This counter displays the total number of calendar days that have elapsed since the counter was reset to help the user track filter usage. Press FAN to reset.
Set Service Filter Runtime Hours (Setup Step 12)
This timer allows the user to specify the number of hours the fan will run before the “Replace Filter” alert will be displayed. Press COOLER continuously until 0 is displayed to disable this alert.
Set Service Filter Calendar Days (Setup Step 13)
This timer allows the user to specify the number of calendar days that will elapse before the “Replace Filter” alert will be displayed. Press COOLER continuously until 0 is displayed to disable this feature.
UV Lamp Runtime (Setup Steps 11, 14)
Current UV Lamp Calendar Days (Setup Step 11)
This counter displays the total number of calendar days that have elapsed since last reset to help the user track UV lamp runtime. Press FAN to reset.
Set UV Lamp Calendar Days (Setup Step 14)
This timer allows the user to specify the number of calendar days the UV Lamp will operate before the “Replace UV Lamp” alert will be displayed. Press COOLER continuously until 0 appears to disable this alert.
Language (Setup Step 15)
Setup step instructions on the scrolling display can be set for English, Spanish, or French.
Scrolling Display Method (Setup Step 16)
This option allows the user to choose how the scrolling text is displayed. Options are:
Cycles Per Hour (Setup Step 17)
The Cycles Per Hour setting may limit the number of times per hour your HVAC unit may energize. For example, at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes. The Cycles Per Hour limit may be overridden and reset by pressing the WARMER or COOLER buttons on the thermostat. Settings are No Limit, 2, 3, 4, 5, or 6.
Compressor Minimum Off Minutes (Setup Step 18)
This feature allows the user to set a minimum off time for the compressor. Settings are 5 mins., 3 mins., or 0 mins.
Minimum Heat/Cool Setpoint Difference (Setup Step 19)
This feature allows the user to set the minimum gap between Heat and Cool setpoints in AUTO mode. Select from 0 to 6. If setup step 2 is not set for AUTO-CHANGEOVER, this step will not appear.
Number of Heat Stages (Setup Step 20)
This setting assures proper stage callouts on the thermostat display for non-heat pump applications.
Number of Cool Stages (Setup Step 21)
This setting assures proper stage callouts on the thermostat display for non-heat pump applications.
Number of Aux Stages (Setup Step 22)
This feature is for heat pump applications only. This feature allows for proper Aux Heat Staging. (0-2 stages)
The Deadband is the number of degrees or minutes that the thermostat waits before it initiates each stage of heating or cooling.
1st Stage Deadband (Setup Step 23)
Specifies the minimum temperature difference between the room temperature and the desired setpoint before the first stage of heating or cooling is allowed to turn on (1 – 6 degrees). For example, if the heat setpoint is 68˚ and the 1st Stage deadband is set to 2 degrees, the room temperature will need to fall to 66˚ before the heat turns on.
Fahrenheit or Celsius (Setup Step 24)
This feature allows the thermostat to display temperature in Fahrenheit or Celsius.
NOTE: If a remote sensor is being used, the degree icon on the large room temperature display will blink.
Dry Contact Polarity (Setup Step 25)
Condensate Dry Contact Use (Setup Step 26)
If selected when the dry contact is active, the thermostat will lockout the compressor terminal(s) and CONDENSATE PAN OVERFLOW will appear on the display.
VACATION – The HOME/AWAY feature allows the thermostat to use temporary, energy saving settings without having to change regular programming. Vacation setup/programming at the local thermostat is limited to the number of days employing Home/Away settings. When the optional Wi-Fi module is detected in the thermostat, local Vacation programming is not allowed. In this case Vacation setup and programming is accomplished with the ProStat+ web portal. The ProStat+ web portal gives the user extensive control over Vacation settings.
Press the Vacation button to enter Vacation/Away programming (no Wi-Fi Module detected).
If there is not a period active:
Use the Warmer and Cooler buttons to choose the number of days desired to run the Vacation feature. To confirm your settings and advance to the next step, press the Vacation button again. Choose the desired Vacation Cool set point. Press Vacation. Then choose the desired Vacation Heat set point. Press Holiday to return to the main screen.
FDD
If FDD is selected when the dry contact is active, the scrolling display will read EQUIPMENT FAULT. This error message will disappear when the Dry Contact is idle.
REMOTE
No action is taken at the thermostat. The dry contact status is simply communicated to the ProStat+ web portal.
ProStat+ Web Portal (Setup Step 27)
If set to ON, the thermostat may communicate and receive data from the ProStat+ web portal.
Local API (Setup Step 28)
Turning the local API to ON allows 3rd party software to interface with your thermostat such as a building automation system.
ADR (Setup Step 29)
Controls whether you want the thermostat to respond to signals from a utility provider. Select ON to allow this and to have steps 76-82 appear.
Price Dependent Action (Setup Step 30)
Allows the user to determine what action is taken when the price rises above the set threshold. Note that the threshold price is only adjustable via Skyport.
Specifies the range of allowable setpoint adjustments to be enforced when any ADR signal has been received from the utility. Since you might be paying more for energy while an event is active, you can impose tighter limits on setpoint ranges that are only enforced during the event.
Specifies the setpoints that will come into use during an event when the PRICE DEPENDENT ACTION is set to OBSERVE STATIC SETPOINT
Specifies how much the current setpoints in effect prior to an event will be altered during an event when the PRICE DEPENDENT ACTION is set to OBSERVE SETPOINT OFFSETS. The heat setpoint can be automatically lowered by 1 to 10 degrees while the cool setpoint can be automatically raised by 1 to 10 degrees.
DISPLAY INDICATIONS WHEN AN ADR EVENT IS HAPPENING
After setting your desired values for use during an ADR event, the scrolling display will give a little information when an event is pending or active. For instance, when an ADR event has been sent to your thermostat, you might see ADR STARTS at 4:15 to notify you of a pending event. Once active, you might see ADR STOPS at 5:30. If you have configured a threshold for cost of energy past which you want to trigger an event, you will see PRICING EVENT on the display. When an event is active, you can press any of COOLER, WARMER or MODE buttons, followed by the WARMER to opt out of the event.
Press Fan To Clear All Messages (Setup Step 37)
This feature allows the user to clear all current error messages from the display.
Locking/Unlocking the Keypad
To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the WARMER and COOLER buttons together, and the
To unlock the keypad, press and hold the MODE button. While holding the MODE button, press the WARMER and COOLER buttons together, and the
If, for any reason, you desire to return all the stored settings back to the factory default settings, follow the instructions below.
WARNING: This will reset all Time Period and Advanced Programming to the default settings. Any information entered prior to this reset will be permanently lost.
To enter Technician Setup, press and hold the SETUP button for 10 seconds. After all the icons appear, press MODE. The version number of the thermostat will appear in the scrolling text. Press MODE to advance to the next step.
Use the WARMER or COOLER buttons to adjust the value of your selection.
To leave Technician Setup, press SETUP.
Technician Setup is for diagnostic and testing purposes and is intended for use by a qualified technician. See next page for more detailed instructions.
Technician Setup contains the following options:
To enter Technician Setup, press and hold the SETUP button for 10 seconds until all the icons appear. Follow the next steps to view settings and test equipment.
PSP Series – Thermostat Models:
PSP1100, PSP1152, PSP2100, PSP2152, PSP2270, PSP2270C, PSP2111, PSP4272, PSP4273, PSP4271C, PSP4272C, PSP4272RT, PSP4273RT, PSP4272CT, PSP4273CT
Who Is Providing The Warranty?
This warranty is provided to you by Goodman Manufacturing Company, L.P. (“Goodman”), which warrants all parts of this thermostat (“control”), as described below.
To What Type Of Installations Does This Warranty Apply?
This warranty applies to controls installed in owner-occupied residences.
What Units Does This Warranty Not Cover?
This warranty does not apply to:
This Warranty Cover?
This warranty covers defects in materials and workmanship that appear under normal use and maintenance.
This warranty is in lieu of all other express warranties. ANY IMPLIED WARRANTIES BY GOODMAN, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THIS WARRANTY. NO AFFILIATE OF GOODMAN GIVES ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, ON THIS UNIT. Some states and provinces
do not allow the exclusion of express warranties and/or limitations on how long an implied warranty lasts, so the above exclusion and/or limitation may not apply to you.
For further information about this warranty contact Consumer Affairs at (877) 254-4729 or by mail to 19001 Kermier Rd, Waller, Texas 77484
What Problems Does This Warranty Not Cover?
Goodman is not responsible for:
When Does Warranty Coverage Begin?
Warranty coverage begins on the “installation date.” The installation date is one of two dates depending on the circumstances of purchase:
How Long Does Warranty Coverage Last?
The warranty lasts for a period up to 1 YEAR.
The warranty period does not continue after the control is removed from the location where it was originally installed. The replacement of a part under this warranty does not extend the warranty period. In other words, Goodman warrants a replacement control only for
the period remaining in the applicable warranty that commenced on the installation date.
What Will Goodman Do To Correct Problems?
Goodman will furnish a replacement control, without charge for the control only, to replace any control that is found to be defective due to workmanship or materials under normal use and maintenance. Furnishing of the replacement control is Goodman’s only responsibility under this warranty and the furnishing of the replacement control is the owner’s only remedy.
THE OWNER AGREES THAT THESE REMEDIES ARE THE OWNER’S EXCLUSIVE REMEDIES FOR BREACH OF ALL WARRANTIES, EXPRESS OR IMPLIED.
What Won’t Goodman Do To Correct Problems?
Goodman will not pay for:
WHETHER ANY CLAIM IS BASED ON NEGLIGENCE OR OTHER TORT, BREACH OF WARRANTY OR OTHER BREACH OF CONTRACT, OR ANY OTHER THEORY, NEITHER GOODMAN NOR ANY OF ITS AFFILIATES SHALL IN ANY EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOST PROFITS, LOSS OF USE OF A CONTROL, EXTRA UTILITY EXPENSES, OR DAMAGES TO PROPERTY.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply to you.
How Can The Owner Receive Warranty Service?
If there is a problem with the control, contact a licensed contractor.
To receive a replacement control, a licensed contractor must bring the defective control to a Goodman heating and air conditioning products distributor.
For more information about the warranty, contact Consumer Affairs at 877-254-4729 or write to Consumer Affairs, 19001 Kermier Rd, Waller, TX 77484.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.
Quebec Residents
The arbitration provisions of this warranty shall not apply to residents of Quebec.
Non-Owner Occupied Warranty
Products installed in non-residential buildings or in residences not occupied by the owner are warranted
for a period of 1 YEAR. THIS WARRANTY IS PROVIDED IN LIEU OF ANY OTHER WARRANTIES, WHETHER BY GOODMAN OR ANY OF ITS AFFILIATES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Subject to the additional limitations set forth in this paragraph, all other provisions of the Limited Warranty apply to products installed in non-residential buildings or in residences not occupied by the owner.
Where Can Any Legal Remedies Be Pursued?
ARBITRATION CLAUSE. IMPORTANT. PLEASE REVIEW THIS ARBITRATION CLAUSE. IT AFFECTS YOUR LEGAL RIGHTS.
Innovation, Science and Economic Development Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NM8-3(B)
Download manual:
Prostat PSP2111 Residential Smart Wi-Fi Thermostat Installation Manual
Prostat PSP2111 Residential Smart Wi-Fi Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…