Caution Equipment damage hazard. Do not operate the cooling system if the outdoor temperature is below 50 ˚F (10 ˚C) to prevent possible compressor damage.
Battery Door Information
Caution:
When the battery icon
Important:
The low battery icon is displayed when the AA battery power is low. Whenever the thermostat detects low battery voltage from the AA batteries, the low battery icon will begin flashing on the screen for 21 days (if the batteries are not changed). If the batteries are not changed 22 days after the thermostat detects low battery voltage, the thermostat screen will only show the flashing battery icon until buttons are pressed. If the batteries are not changed 43 days after the thermostat detects low battery voltage, the thermostat screen will only show the flashing battery icon until buttons are pressed and the set points will offset to 85°F/29°C in cooling and 55°F/13°C in heating. At this stage, set point changes can be made temporarily but, the set points will change back to defaulted values after a 4-hour period. The thermostat will continue to perform this low battery flashing, temperature offset condition until the internal voltage threshold is reached. When the thermostat internal voltage threshold is reached, all relays will be opened and the thermostat will become inoperable until new batteries are installed.
Set Time (If using programming)
Follow the steps below to set the day of the week and current time:
(WAKE, LEAVE, RETURN, SLEEP)
To customize your 5+1+1 Program schedule, follow these steps:
Weekday:
Saturday:
Repeat steps 4 through 7 for the Saturday WAKE time period, for the Saturday LEAVE time period, for the Saturday RETURN time period, and for the Saturday SLEEP time period.
Sunday:
Repeat steps 4 through 7 for the Sunday WAKE time period, for the Sunday LEAVE time period, for the Sunday RETURN time period, and for the Sunday SLEEP time period.
To customize your 7 day Program Schedule, repeat steps 4 through 8 for the Tuesday, Wednesday, Thursday, Friday, Saturday and Sunday time periods.
A Note About Programmable Fan:
The programmable fan feature will run the fan continuously during during any time period when it is programmed to be on. This is the best way to keep the air circulated and to eliminate hot and cold spots in your building.
Temporary Hold:
The thermostat will display HOLD and RUN SCHED on the bottom of your screen when you press the
Permanent Hold:
With a temporary hold set, if you press the HOLD key at the bottom of your screen, you will see HOLD appear below the setpoint temperature in the display. The thermostat will now permanently stay at this setpoint and can be adjusted using the
To Return To Program:
Press the RUN SCHED key at the bottom of your screen to exit temporary and permanent holds.
Keypad Lockout Note:
If
A Note About Auto Changeover:
When in Auto you have the ability to switch between auto heat or auto cool by pressing the system key. This can be done once the current mode has reached its setpoint. For example: if in auto heat, the heat setpoint must be satisfied before the thermostat will allow you to switch to auto cool. You can switch out of auto by holding down the system key. To get back into auto, you must toggle the system key to auto.
Filter Change & Other Reminders
If your HVAC contractor has configured the thermostat to remind you when the air filter needs changed, you will see a reminder in the display when your air filter needs to be changed.
Resetting The Filter Change Reminder: When the reminder is displayed, you should change your air filter and reset the reminder by holding down the Set Time/Next Step button of the thermostat for 3 seconds.
Warranty Registration
Your new thermostat has a 5 year limited warranty. You must register your thermostat within 60 days of installation. Without this registration the warranty period will begin on the date of manufacture. For warranty issues please contact the HVAC professional that installed this product. You can register your new thermostat in 2 ways:
Online
Go to the company website, select warranty registration and fill out a short registration form.
Mail
Complete the form below and mail it to the address shown.
Warranty Registration
Thermostat Warranty Registration
Pro1iaq
P.O. Box 3377
Springfield, MO 65808-3377
www.pro1iaq.com
Download Manual:
Pro1 Technologies T805 Non-Programmable Thermostat Operational Manual
OTHER MANUALS
Pro1 Technologies T805 Non-Programmable Thermostat Installational Manual
Pro1 Technologies T805 Non-Programmable Thermostat Product Specifications Guide
Pro1 Technologies T805 Non-Programmable Thermostat Operational Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…