Pro1 Technologies

Pro1 Technologies T715 Non-Programmable Thermostat Operational Manual

Pro1 Technologies T715 Non-Programmable Thermostat

Pro1 Technologies
P.O. Box 3377
Springfield, MO 65808-3377
Toll-Free: 888-776-1427
Web: www.pro1iaq.com
Hours of Operation: M-F 9 AM – 6 PM Eastern

Caution
Equipment damage hazard. Do not operate the cooling system if the outdoor temperature is below 50 ˚F (10 ˚C) to prevent possible compressor damage.

Thermostat Operation

  1. LCD Display
  2. Glow in the dark light button
  3. Fan Switch
  4. System Switch
  5. Temperature Setpoint Buttons
  6. User Buttons
  7. Easy change battery door
    1. LCD Display
      See page 4 for details about this display readout.
    2. Glow in the dark light button
      The glow-in-the-dark light button will self-illuminate for several hours after exposure to ambient light. This button turns on the display light when pressed.
    3. Fan Switch
      Select ON or AUTO. ON will run the fan continuously. AUTO will cycle the fan on only when the heating or cooling system is on.
    4. System Switch
      Selects the operation mode on your HVAC system. Selecting HEAT turns on the heat mode. Selecting COOL turns on the air conditioning mode. Selecting OFF turns both heating and cooling off.
    5. Temperature Setpoint Buttons
      Press the + or – buttons to select the desired room temperature.
    6. User Buttons
      Use these buttons to set up your programming options. Refer to the next page for detail.
    7. Easy Change Battery Door See page 5 for details.

Caution: When the battery icon appears replace your AA batteries immediately. Failure to do so may result in your heating & cooling system becoming inoperable. Freezing or overheating can occur.

Thermostat Quick Reference

Important: The low battery indicator is displayed when the AA battery power is low. If the user fails to replace the battery within 21 days, the screen will only show the low battery indicator but maintain all functionality. If the user fails to replace the batteries after an additional 21 days (days 22-42 since the first “low battery” display) the set points will change to 55˚F(Heating) and 85˚F(Cooling). If the user adjusts these setpoints away from these it will hold for 4 hours and then return to either 55˚F or 85˚F. After day 63 the batteries must be replaced immediately to avoid freezing or overheating because the thermostat will shut the unit off until the battery is changed.

Battery Door Information

Temporary and Permanent Hold Feature
When cool or heat is turned on, the thermostat will display HOLD and RUN SCHED on the left of your screen when you press the or button.
Temporary Hold: At this time if you do nothing, the temperature will remain at this setpoint until the next scheduled time period.
Permanent Hold: If you press the HOLD key on the left of your screen, you will see HOLD appear below the setpoint temperature in the display. The thermostat will now permanently stay at this setpoint and can be adjusted using the or keys.
To Return to Running Schedule: Press the RUN SCHED button on the left of your screen to exit either temporary or permanent hold.

Filter Change Reminder
If your HVAC contractor has configured the thermostat to remind you when the air filter needs to be changed, you will see FILT in the display when your air filter needs to be changed.
Resetting the filter change reminder: When the FILT reminder is displayed, you should change your air filter and reset the reminder by holding down the second button from the top left side of the thermostat for 3 seconds.

Set Time

  1. With the system switch set to OFF, press the MENU button
  2. Press SET TIME
  3. The day of the week will be flashing. Use the or key to select the current day of the week.
  4. Press NEXT STEP
  5. The current hour is flashing. Use the or key to select the current hour. When using 12-hour time, make sure the correct a.m. or p.m. choice is selected.
  6. Press NEXT STEP
  7. Minutes are now flashing. Use the or key to select current minutes.
  8. Press DONE when completed.

Set Program Schedule 5+1+1 or 7 Day

  1. Select HEAT or COOL with the system switch. Note: You have to program heat and cool each separately.
  2. Press the MENU button (If the menu does not appear first press RUN SCHED)
  3. Press SET SCHED. Note: Monday-Friday or (Monday if in 7 Days) is displayed and the WAKE icon is shown. You are now programming the waketime period for that day.
  4. Time is flashing. Use the or key to make your time selection for that day’s WAKE time period.
  5. Press NEXT STEP
  6. The setpoint temperature is flashing. Use the or key to make your setpoint selection for that day’s WAKE time period.
  7. Press NEXT STEP
  8. Repeat steps 4 thru 7 for that day’s LEAVE time period, RETURN time period, and SLEEP time period.

Set Program Schedule 5+1+1 or 7 Day (Continue…)
Saturday: Repeat steps 4 through 7 for the Saturday WAKE time period, LEAVE time period, RETURN time period, and for the Saturday SLEEP time period.

Sunday: Repeat steps 4 through 7 for the Sunday WAKE time period, LEAVE time period, RETURN time period, and for the Sunday SLEEP time period.If using 7-Day Programming use the previous steps for every individual day. You can also use these time-saving functions. You must be in Set Sched Programming Mode (Press Menu >> Press Set Sched) for the following functions to work:

  1. To copy ALL time periods and temperatures of the current system and day to ALL days, Press and Hold the 2nd button down on left until the Days and Time flash.
  2. To copy ALL time periods (only times) for ALL days to the opposite system (Heat to Cool / Cool to Heat), Press and hold the Glow in the Dark Light button down until Set Time and Time flash.

Warranty Information

Warranty Registration
Your new thermostat has a 5-year limited warranty. You must register your thermostat within 60 days of installation. Without this registration, the warranty period will begin on the date of manufacture. For warranty issues please contact the HVAC professional that installed this product. You can register your new thermostat in 2 ways:

Online
Go to the company website, select warranty registration, and fill out a short registration form.

Mail
Complete the form below and mail it to the address shown.

Warranty Registration

Thermostat Model: ————————————————-
Date Installed:————————————-
Complete the form and mail it to Thermostat Warranty Registration Pro1iaq———————————
P.O. Box 3377————————————–
Springfield, MO 65808-3377————————————

Cut Out For Warranty Registration www.pro1iaq.com

Reference

Download Manual:

Pro1 Technologies T715 Non-Programmable Thermostat Operational Manual

OTHER MANUALS

Pro1 Technologies T715 Non-Programmable Thermostat Installational Manual

Pro1 Technologies T715 Non-Programmable Thermostat Product Specifications Guide

Pro1 Technologies T715 Non-Programmable Thermostat Operational Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago