This device is a Z-Wave sensor and a Z-Wave actuator which can integrate a water based room radiator into a Z-Wave network. Click on the
Please refer to the chapters below for detailed information about all aspects of the products usage.
This device is a Z-Wave controlled electronic radiator thermostat. It is mounted on wall heating valves and controls them by a motor. The device accepts a setpoint that is either set manually using buttons on the device or wirelessly using Z-Wave. Afterward, the device will regulate the warm water supply to the wall radiator and compare the detected temperature to ensure, that the temperature in the room is kept at the desired level. A small LCD panel on the device displays the setpoint temperature on request.
The device has an internal scheduler, that allows defining up to 9 setpoints for up to 7 week days. Once programmed, these setpoints will be activated without any further manual or wireless interaction. Beside setting a desired temperature the device will support special heating schemes, such as energy saving and frost protection and intelligent functions like a valve training function to ensure that valves are still operational after longer periods.
The Popp radiator thermostat can be mounted to valves with standard M30x1.5 connector or RA2000.
Opposite to the Danfoss TRV this device will report the room temperature as detected and calculated by the device’s temperature sensor.
1. Start by mounting the appropriate adapter. |
|
2. Tighten RA adapter using the Allen key, hand-tighten the K adapter (max. 5 Nm). | |
3. Screw the thermostat onto the adapter and tighten by hand (max. 5 Nm). | |
4. A large |
Behavior within the Z-Wave Network
On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion mode. Please refer to your primary controller’s manual on how to turn your controller into inclusion or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network – i.e. being excluded – sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to be reset first.
Quickly press and release the function button for Inclusion/Exclusion. Observe both controller and Popp radiator thermostat for status of the process.
The radiator thermostat is operated by wireless commands from a Z-Wave controller. It is operated in two different modes:
The actual temperature set point is shown in the LCD display and can be overwritten by using the arrow keys on the device. If this is done, the thermostat sends a message to the controller, which then synchronizes other thermostats in the same room.
The device will also recognize an open window (sudden temperature drop within short period of time) and turn down the heat for 30 minutes to save energy.
Link Test
If the thermostat has been removed from the radiator and needs to be reinstalled (after being used), it is necessary to activate installation mode to prevent damage to the thermostat.
To enter the installation mode:
If the thermostat is moved to another room, make sure to make the necessary changes in the controller.
Factory Reset
Remove the battery cover and take out one battery. Press and hold the fuction button for approx. 5 seconds, while re-inserting the battery. The Popp radiator thermostat is now factory reset and in mounting mode.
The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. A simple click on the function button sends a NIF.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, …). In case the event happens all devices stored in the respective association group will receive a common wireless command.
Association Groups
Battery Type | 2*AA |
Frequency | 868.4 MHz…869.3 MHz |
Wireless Range | On average up to 40 m inside buildings |
Explorer Frame Support | Yes |
SDK | 4.55 |
Device Type | Slave |
Generic Device Class | Thermostat |
Specific Device Class | Setpoint Thermostat |
Routing | No |
Firmware Version | 1.0 |
Explanation of Z-Wave specific terms
The product contains batteries. Use only batteries of correct type. Never mix old and new batteries in the same device. Used batteries contain hazardous substances. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging health and well-being.
Should you encounter any problem, please give us an opportunity to address it before returning this product. Most questions regarding Z-Wave wireless communication standard can be answered through the international community at www.z-wave.info.
If your question can’t be answered there, please use www.popp.eu/support or contact us by email: info@popp.eu
© 2016 POPP & Co.
While the information in this manual has been compiled with great care, it may not be deemed an assurance of product characteristics. Popp & Co. shall be liable only to the degree specified in the terms of sale and delivery.
The reproduction and distribution of the documentation and software supplied with this product and the use of its contents is subject to written authorization from Popp & Co. We reserve the right to make any alterations that arise as the result of technical development.
Phone: +44 (0) 20 7419 5726
eMail: info@popp.eu
Web: www.popp.eu
Download manual:
Popp 010101 Radiator Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…