Poer

Poer PTC20 WIFI Programmable Room Thermostat User Manual

PTC20 WIFI Programmable Room Thermostat

Overview

This wireless programmable room thermostat kit can be used to control gas or oil boiler, a variety of valves and actuators.

This thermostat is a programmable room thermostat 5+2 Days/ 7 Days/1 day product. 5+2 days allows you to set a program for weekdays and a program for the weekend. 7 days allows you to set a same program for every day of the week. 1 day functionality allows you to set a different program for every day of the week. Each program type allows you to set 12 time and temperature events.

Controls and Display Layout

Installation

Installation of PTC20
Follow the installation diagrams to install and connect the PTC26 correctly. This thermostat is adapted to 86mm hidden box and 60mm European box.

  1. The installation and wiring should be operated by trained personal.
  2. The PTC20 needs a 100~240V AC mains supply to operate, and this should be fused appropriately (SA max.).
  3. The PTC20 should be mounted in a location where it will not come into contact

Note: with water, moisture or condensation.

  1. Use a flat-blade screwdriver to open the front cover of the thermostat from snap hole at the bottom.
  2. Wiring the terminal correctly, then fasten the screws.
  3. Secure the thermostat back cover to the junction box with 2 screws.
  4. Close the front cover.

Wiring thermostat PTC20

Note

  1. Install in accordance with local wiring regulations.
  2. The wiring should be operated by trained personnel. A
  3. Observe ambient temperature and current limits (see product data sheet).
  4. These wiring diagrams must be referenced and combined with the corresponding instructions provided by the actual equipment manufacturer.
  5. Lancable accepts no liability for any loss or damage arising from any errors or omissions that may be inadvertently contained within these diagrams. They are proposal diagrams only, not certified wiring diagrams.

System settings

Thermostat WIFI settings

  1. Scan the QR code below or search “poersmart” in Google play or APP store to download and install ii. Aller installation, register the account as required.
  2. Add the thermostat PTC20 as prompted on the APP under registered account.

Thermostat operation

Time setting
Follow the installation diagrams to install and connect the PTC20 correctly. This thermostat is adapted to 86mm hidden box and 60mm European box.

  1. Enter Menu Selection by long pressinguntil there is a flashing , then enter Clock Setting by pressing
  2. Firstly set Year after entering Clock Setting, when appeared on Temperature Area, press to select the current year and pressto set.
  3. When appeared on Temperature Area, press to select current month and press to set.
  4. When appeared on Temperature Area, press to select current date and press set.
  5. When clock setting is flashing on Time Area, press 0 C=J to select current time and pressto confirm.
  6. Back to the last setting menu by pressing

Pre-set Program
This thermostat comes with the following default settings pre-programed for your convenience:

Working days’ pre-set program

Event 1 2 3 4 5 6 7
Time 00:00 6:30 8:30 12:00 14:00 16:30 22:30
Temperature 7 20 16 16 16 21 7

Weekend’s pre-set program (Sat., Sun.)

Event 1 2 3 4 5 6 7
Time 00:00 7:00 9:00 12:00 14:00 16:30 23:30
Temperature 7 20 18 21 18 21 7

To adjust the pre-set program
After adding the device, please operate it in the programming function of the app. For offline operation, please scan the QR code to view it.

AUTO mode
In AUTO mode, if you want to temporarily adjust the current temperature value, you can change the current temperature setting by operating the control panel.

  1. Under AUTO mode, enter Override mode by pressing AUTO MAN appeared on upper right when changing the setting., if you want to temporarily adjust the current temperature value, you can change the current temperature setting by operating the control panel.
  2. The current programming period is recorded when entering the override mode, and  the end time of the override mode is the programming end time of the period.

Temperature manually
Manual Mode-to set a constant room temperature manually.
Switch between AUTO and Manual Mode by pressing Adjust required temperature under MAN mode by pressing Setting temperature display to the bottom left of the display.

Holiday Mode 

  1. Make a holiday plan, it will keep your room at the pre-set temperature until your return time is coming. The default temperature for Holiday Mode is 7 C, you also can change this default value in User Options or APP.
  2. Offline local setting holiday mode Please scan the QR code to view it.

ECO Mode

It is an quick access to energy saving but also maintain comfort. Under ECO Mode, the room will be always kept at a pre-set temperature unless you exit this mode. The default temperature is 9 C, you can change this default value in User Options or APP.

  1. Enter ECO Mode by pressing
  2. Exit ECO Mode by pressing

OFF Mode (Frost Protection)
Under OFF Mode, your room’s Frost Protection will be automatically turned on unless you exit the mode; The default temperature is 7 C, you can change this default value in User Options.

  1. Enter OFF Mode by long pressing
  2. Exit OFF Mode by pressing

Child Lock
To avoid wrong operation by child, this thermostat has Child Lock function; once started this function, there will be no reaction if short press on any button.

  1. Long press to enter Menu Selection, select by confirm by pressing to enter Child Lock function when is flashing.
  2. Cancel Child Mode by long pressing

Turn off the display
Long press and  simultaneous to turn off the display, Press to turn on the display.

User Option

You may change user option after entering User option by Pressing when User option is flashing under Menu Selection.

  1. Under User Option, the option ID is showing on Temperature Area(screen left side), the Option Content is shown on Time Area(screen right side).
  2. Option ID is flashing under User Option(details to see User Options Table below ), press to scroll through selectable options, select the target Option ID by pressing then, adjust the User Option by pressing and set it down by pressing . Press GJ U to set other User Options.
  3. To cancel User Operation’s setting, press when Option Content flashing.
  4. To exit User Operation’s setting, presswhen Option ID flashing.

User Options Table

ID Option Content Min. Max. Default
1 Change 12h or 24h clock 12 24 24
2 Change to another pre-set program 1 3 1
4 Change temperature offset°C (0.5°C / step) -10 10 0
5 Restore the factory Settings OFF ON OFF
6 To disable Off function OFF ON OFF
7 Frost Protection OFF ON ON
8 Pre-set the lowest temperature 0 5 5
9 Pre-set the highest temperature 32 60 32
10 Pre-set the ECO temperature 5 32 9

 

11

Valve Protection(unit: min., if the valve has not been opened for 24hours, it will be automatically opened every 1O:OOam ; “O” means no Valve Protection. )

 

0

5

 

0

12 Change degrees Celsiusor or Fahrenhieit C F C
17 Change humidity offset -30 30 0
18 PIO control function OFF ON OFF
19 PIO control hysteresis adjustment 0.1 1.0 0.3 ( ±0.3 °C )

20

Temperature control hysteresis adjustment

0.1

1.0

0.3 ( ±0.3 °C )

21 Window opening function OFF ON OFF
22 Window opening stop heating time 0 60 60 (minute)

23

OFF mode target temperature range setting

ld8

ld9

s0  c
Warning: User option 19, 20 substantial reduction in sensitivity may lead to frequent on and off heating, especially when using automatic PIO control, in the worst case it may damage the heat source.

Thermostat PTC20

Operating Temperature o – so0    c
Control mode Heating system
Display LCD with backlight
Temperature control range 5′ C – 32’C (0.5’C/step)adjustable in useroption from O’ C to 60’C
Temperature control accuracy ±0.3°C/adjustablefrom ±0.1°C to ± 1.0°c
Antifreeze temperature s0   c
Humidity range 10to90%RH
Humidity accuracy ±5%RH
Time display 12 hour/24 hour
Dimensions (HxWxD) 86 x 86 x 40.5mm
IP class lp30
Standard CE
Power 2W
Power supply 100VAC – 240VAC, 50Hz
Switch rating 240VAC 50Hz , 5A
Switch type SPOT relay

Technical specifications are subject to change without notice

Reference

Download Manual:

Poer PTC20 WIFI Programmable Room Thermostat User Manual

Poer PTC20 WIFI Programmable Room Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago