Poer

Poer PTC10 WIRELESS Programmable Room Thermostat User Manual

Poer PTC10 WIRELESS Programmable Room Thermostat

Overview

  • This wireless programmable room thermostat kit can be used to control gas or oil boiler, a variety of valves and actuators.
  • II contains a wireless programmable room thermostat PTC10 and a wireless receiver PTR10, the two units are linked by Radio Frequency. (If your kit is Wi-Fi thermostat, there is a gateway PTG10 accessing your thermostat to internet)
  • This thermostat is a programmable room thermostat 5+2 Days / 7 Days/1 day product. 5+2 days allows you to set a program for weekdays and a program for the weekend. 7 days allows you to set a same program for every day of the week. 1 day functionality allows you to set a different program for every day of the week. Each program type allows you to set 7 time and temperature events.

Controls and Display Layout

  • A Days
    B Temperature
  • C Program setting time
  • D ECO
    + or – buttons for setting
  • F Confirm
  • G Return
  • H Auto, Manual, Holiday mode
  • RF
  • J Time
  • K Humidity
  • Copy
  • Clock set
  • Child lock
  • Program set
  • Forst protection
  • Heating
  • Low battery warning
  • Open window

System Installation

Install and Wiring Receiver

Install Receiver
Follow the installation diagrams to install and connect the receiver PTR10 correctly.

Note:

  • The installation and wiring should be operated by trained personal.
  • The Receiver should be mounted in a suitable location that is both accessible for the connection of mains and control wiring, and allows good reception of the RF signal. The Receiver needs a 100-240V AC mains supply to operate, and this should be fused appropriately (5A max.).
  • The Receiver should be mounted in a location where it will not come into contact with water, moisture or condensation

Wiring Receiver

Note:

  1. Install in accordance with local wiring regulations.
  2. The wiring should be operated by trained personnel.
  3. Observe ambient temperature and current limits(see product specification).
  4. These diagrams must be read in conjunction with any boiler or cylinder manufactures instructions.
  5. Poer accepts no liability for any loss or damage arising from any errors or omissions that may be inadvertently contained within these diagrams. They are proposal diagrams only, not certified wiring diagrams

Volt free contacts

Combi boiler

Burner(direct control)

Electric heater

Zone valve

Thermal actuator

Activate Batteries and Install Thermostat

Activate Batteries

Install Thermostat
This thermostat could be desk-stand if open the back support, you just need to place it on any flat surface allows to receive RF signal.

If you want to hang it on the wall, use the template provided.
Drill two holes in the wall and tighten the screws, ensuring two holes’ distance is 81.5mm; then, fix the thermostat’s back cover by putting it over the screw head.

System Check

RF Signal Pairing
The room thermostat has already been pre-bound with the receiver’s OVERRIDE I In kit PTC10/PTR10 when delivery. You may directly move to RF communication test, please refer to 2.3.2.

RF signal pairing between room thermostat and receiver

  • Preparation: thermostat and receiver should be powered/wired correctly, make sure the visible distance between the thermostat and receiver is not more than 5 meters.
  • Start the receiver’s RF pairing mode by hold-pressing the LEARN button until its light flashes.
  • Press OVERRIDE Ⅰor Ⅱ(you must choose according to your real wiring work on the receiver) to pair with the thermostat; when the light of OVERRIDE Ⅰor Ⅱ is flashing, it means OVERRIDE Ⅰor Ⅱ is ready to pair with the thermostat next.
  • The thermostat sends pairing command with receiver:
    • Long press to enter Menu Selection, select by pressing when are flashing, press to enter RF pairing interface

  • When is flashing on the screen’s left side, press to send the pairing command with the receiver;
    • Pairing is success if flashing on the screen’s right side, pairing failed if E01 or E02 is flashing on the screen’s right side, in this case, you need to send the pairing command to the receiver by pressing once again until pairing is success.

  • Exit pairing mode: Exit pairing mode by pressing LEARN button; thermostat’s HOME page can be returned by keep pressing 
  • Once the thermostat and receiver were paired successfully, their RF communication started normally, will show up on the top right corner of the thermostat’s screen

Automatically pairing thermostat with gateway by App on mobile phone

  • Open the App. which is already connected with the gateway(how to add a gateway on App. please refer to gateway’s manual for details), choose Add Thermostat from the interface;

  • Add thermostat by scanning its QR code or typing MAC ID manually.
  • Pairing process between the thermostat and gateway might take about 1 minute. Once the thermostat is paired with the gateway successfully, will show up on the top right corner of the thermostat’s screen; App. the interface also shows up the added thermostat’s

Manually paring thermostat with gateway

  • Preparation: Powered gateway correctly by plug-in socket, the LED on gateway will be blinking rapidly (LED blinking rapidly means no connection between gateway and server).
  • Start gateway’s pairing mode by hold pressing until its LED is blinking slowly.
  • Thermostat send pairing command with gateway.
  • Long press to enter Menu Selection, when are flashing, press to enter RF pairing interface

  • On RF pairing interface, select by pressing on until flashing show up on screen’s left side, press to send thermostat’s paring commend to gateway; pairing success if flashing on screen’s right side, pairing failed if E01 or E02 is flashing on screen’s right side, in this case, you need to send the paring command with gateway by pressing once again until pairing success.

  • Gateway is still under paring mode even one thermostat’s paring succeed, if you had more thermostats need to be paired, you may continue to pair them with gateway manually. (1 gateway could RF communicate with 10 thermostats at one time).
  • Exit pairing mode by hold-pressing until the LED recover to its status before pairing.
  • Once thermostat and gateway was paired successfully, their RF communication started normally, will show up on the top right corner of thermostat’s screen; App. interface also show up the added thermostat’s information.

RF communication test

To make sure RF communication between thermostat and receiver, thermostat and gateway before using them regularly, you should take a RF communication test.

RF communication test between thermostat and receiver
Enter RF Communication Test by long pressing, when show up on screen’s left side, press to test RF communication between the thermostat and receiver; test result is good if shows up on the screen’s right side, otherwise, will show up on the screen’s right side, in this case, you need to relocate the thermostat and do the test once again.

RF communication test between thermostat and gateway
Enter RF Communication Test by long pressing , when show up on screen’s left side, press to test RF communication between thermostat and gateway; test result is goodif show up on screen’s right side, otherwise, will show up on screen’s right side, in this case, you need relocate the thermostat and do the test once again

Operation Thermostat

Clock Setting
Clock setting should be done if thermostat was used for the first time or after batteries changed; automatically clocking setting will be done if thermostat was connected with Internet via Gateway

  • Enter Menu Selection by long pressing , select by until there is a flashing , then enter Clock Setting by pressing

  • Firstly set Year after entered Clock Setting, when appeared on Temperature Area, press to select current year and press to set.

    • When appeared on Temperature Area, press to select the current month and press to set.
    • When appeared on Temperature Area, press to select current date and press to set
    • When clock setting is flashing on Time Area, press to select current time and press to confirm.

 

  • Back to the last setting menu by pressing

Program Setting

Pre-set Program

This thermostat comes with the following default settings pre-programmed for your convenience:

Working days’ pre-set program

Weekend’s pre-set program (Sat., Sun.)

To adjust the pre-set program

  • Enter Program Setting by Pressing when is flashing.
  • Enter 5+2 days/7 days/1 day program when Days flashing, select by press to confirm.
  • Temperature flashing in Temperature Area, press to adjust the required temperature, press to confirm.
  • Time flashing in Time Area, press to adjust the 1st time as required, press to confirm.
  • Once the temperature and 1st time has been set, temperature flashing in Temperature Area again, then you repeat to set the next temperature and time periods, as above steps  howing (checking from Step 3).
  • To cancel the program by pressing , go back to Menu Selection by keeping pressing.
  • Long press can copy the current flashing day’s program setting to other day; select target day by pressing , press to confirm and paste

Override Mode-to change temperature for a short period under AUTO mode

  • Under AUTO mode, enter Override mode by pressingBappeared on upper right.
  • Adjust the required temperature by pressing confirm the Noverride temperature after flashing for 7 sec. or pressing, then continue to show current temp-erature.
  • Exit Override Mode until next change in the preset program

Manual Mode-to set a constant room temperature manually

  • Switch between AUTO and Manual Mode by pressing
  • Under Manual mode MAN, appeared on upper right and temperature flashing. Figure as following.

  • Adjust required temperature by pressing , confirm after flashing for 7 sec. or pressing , then continue to show current temperature.

Holiday Mode
Make a holiday plan, it will keep your room at the pre-set temperature until your return time is coming. The default temperature for Holiday Mode is 7℃, you also can change this default value in User Options.

  • Enter Holiday Mode by keep pressing until showing on upper right.

  • Pre-set date and time for holiday start and return.

  • Holiday Mode will start automatically when the holiday start time is coming, otherwise, it continue AUTO Mode.
  • To cancel Holiday Mode’s setting by keep pressing.

ECO Mode

  • Enter ECO mode by pressing, Following is the figure:
  • Exit ECO mode by pressing

OFF Mode (Frost Protection)

  • Enter OFF Mode by long pressing, following is the figure:
  • Exit OFF Mode by pressing

Child Lock

  • Long press to enter Menu Selection, select by , and confirm by pressing to open Child Lock function when is flashing.
  • Cancel Child Mode by long press

User Option

  • You may change user operation after entered User Operation by Pressing when USER is flashing under Menu Selection.

  • Under User Option, the option ID is showing on Temperature Area(screen left side), the Option Content is shown on Time Area(screen right side).

  • Option ID is flashing under User Option(details to see User Options Table below), press to scroll through selectable options, select the target Option ID by pressing; then, adjust the User Option by pressing and set it down by pressing
  • To cancel User Operation’s setting, press when Option Content flashing.
  • To exit User Operation’s setting, press when Option ID flashing

User Options Table

ID Option Content Min. Max. Default
1 Change 12h or 24h clock 12 24 24

2

Change to another pre-set programme

1

3

1

3 Switch on/off summer/winter time OFF ON ON
4 Change temperature offset℃ -5 5 0
5 Restore the factory Settings OFF ON OFF
6 To disable Off function OFF ON OFF
7 Frost Protection OFF ON ON
8 Pre-set the lowest temperature 5 32 5
9 Pre-set the highest temperature 5 32 32
10 Pre-set the ECO temperature 5 32 9

 

11

Valve Protection(unit: min., if the valve has not been opened for 24hours, it will be automatically opened every 10:00am; “0” means no Valve Protection

 

0

 

5

 

0

12

Activate Smart Remote Control (App remote control)

OFF

ON

OFF

(ON for Wi-Fi thermosta)

13

Change degrees Celsiusor or Fahrenhieit

C

F

C

Product Specification

Operating Temperature 0 to 50°C
Control mode Heating system
Display LCD with backlight
Transmitting frequency 868 MHz(433 MHz-PTC10-433),

2 way

Communication Range (open space)

100 meters

Power supply 2 x AA alkaline batteries
Battery life Typically 2 years
Temperature setting range 5°C to 32°C (0.5°C step)
Temperature control accuracy +/-0.3°C
Measurement interval every minute
Frost protection temperature 7°C
Humidity range 10 to 90%RH
Humidity accuracy +/-5%RH
Time display 12 hour/24 hour
Dimensions(HxWxD) 117.2 x 87.2 x 26.6mm
IP class IP30
Standard CE
Weight 211g with battery
Operating Temperature 0 to 50°C
Transmitting frequency 868 MHz(433 MHZ, PTR10-433),

2 way

Communication Range (open space)

100 meters

Power 2W
Power supply 100VAC~240VAC, 50Hz
Switch rating 240VAC 50Hz, 5A resistive, 2A inductive
Switch Type SPDT relay
Dimensions (HxWxD) 98.3x 98.3 x 31.3mm
IP class IP30
Standard CE
Weight 145g

Reference

Download Manual:

Poer PTC10 WIRELESS Programmable Room Thermostat User Manual

Other Manual:

Poer PTC10 WIRELESS Programmable Room Thermostat Product Specification Guide

Poer PTC10 WIRELESS Programmable Room Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago