As the product must be connected to a 230V power supply and to heating equipment, the installation must be carried out only by qualified personnel, in order to avoid irreparable damage to the product or the heating equipment to which it is connected. Also, the first configuration of the equipment should be performed by qualified personnel.

Technical specifications

Transmitter power supply 2 x AAA batteries 15.V
Receiver power supply 230VAC, max. 10A
Frequency 868 MHz
The interval of set temperature +5°C ~ +35°C
Interval of displayed temperature 0°C ~ +50°C
Display Yes, backlighted
Sensor NTC 3950, 10KOhm@25°C
Accuracy ±0.1°C
Step 0.5°C
Temperature measurement unit Only Celsius degrees
Water protection class IP30
Housing ABS with fireproof standard UL94-5

Installation instructions

The thermostat can be mounted in 2 ways: on the table or on the wall with the help of the brackets included in the package.

Description of keys and icons

Pairing transmitter and receiver

Note: the two units come paired from the factory. Make the pairing procedure only if there are communication problems.
Long press the pairing button on the receiver unit.
LED 1 flash frequently.
Turn off the transmitter unit by pressing the key.
Press and hold the MENU key on the transmitter unit until the pairing code appears on the display (for example FF FF 0). Immediately press the ▲ key. Another code will flash on the screen. If the pairing was successful, the code on the screen will disappear and LED 1 (green)will turn off. Turn on the transmitter unit. If the set temperature is higher than the room temperature, the transmitter unit will send an RF signal to the receiver unit, which, in turn, will send an ON command to the boiler. In this situation, LED 1 (red) will remain lit.
Set the time and day of the week
Hold down the MENU key for 3 seconds. The minute indicator will flash. Use the ▲ and ▼ keys to reach the desired value. Briefly press the MENU key to confirm and move to the time setting. The time indicator will flash. Use the ▲ and ▼ keys to reach the desired value. Briefly press the MENU key to confirm and move to the day of the week setting (1 to 7). Press the MENU key to exit.

Operation mode setup 
Briefly press the MENU key to set the operation mode: Scheduled, Manual or Holiday.
In Scheduled mode, the PRG icon appears on the right side of the screen as in the image below:

In Manual mode, only the time, day and temperature are displayed on the screen:

In Holiday mode (Economic), on the right side of the screen appears an icon in the form of a suitcase as in the image below:

Scheduled mode

Schedule by day
Briefly press the MENU key to set the Scheduled operating mode.
Long press the PRG key for 3 seconds to enter the programming menu.
The time* and temperature* will flash on the screen.
Each time you press the PRG key, the selected value will be confirmed and you will move on to the next setting. After setting the time and the temperature for the first period, it automatically switches to the second period, then to the third and fourth. Thus will continue with the setting of the 4 periods for each day of the week (1 – 7).

* Note: The time can be set from 15 to 15 minutes and the temperature from half to half a degree. For example, you can set the time to 07:15 or 07:30 or 07:45 and the temperature to 22.0°C or 22.5°C or 23.0°C.
Note: Briefly press the PRG key to confirm a setting. Press the MENU key to exit.
Default settings

Period 1 2
Hour Temp. Hour Temp.
12345(Mon-Fri) 07:00 22°C 08:30 19°C
6 (Sat) 08:00 22°C 08:30 22°C
7 (Sun) 08:00 22°C 08:30 22°C
Period 3 4
Hour Temp. Hour Temp.
12345(Mon-Fri) 17:00 22°C 17:00 19°C
6 (Sat) 17:00 22°C 22:00 19°C
7 (Sun) 17:00 22°C 22:00 19°C

Note: Press the ▲or ▼key to display the set temperature on the screen. Wait a few seconds, the screen will return to room temperature display mode.

Functions

Key lock function
If the Child protection function has been activated in the advanced settings menu (see page 12), the thermostat keys will lock as soon as the screen backlight turns off.
Press the MENU key for 5 seconds to temporarily unlock the keys.

Open window detection (OWD)
If the function has been activated from the advanced settings menu (see page 12), the thermostat will turn off the heating if the room temperature drops suddenly (default setting 2°C in 15 minutes). This sudden drop in temperature occurs when a window or door is opened while the boiler is operating. The OP icon appears on the screen.
The device will return to its original operating mode after 30 minutes. The OP icon disappears from the screen. By pressing any key, you will exit OWD mode.

Advanced settings
Switch off the thermostat by briefly pressing the key.
Press the MENU and ▲ keys simultaneously for about 6 seconds. 01 0.3°C will appear on the screen. Use the ▲ and ▼ keys to change the settings and the MENU key to move to the next setting.

Menu Description Range Default
01 Internal sensor temperature calibration -8°C~8°C 0°C
02 Setting the maximum temperature limit 5°~35°C 35°C
03 Set minimum temperature limit 5°C~35°C 5°C
05 Anti-freeze temperature 5°C~15°C 5°C
09 Hysteresis 0.1~6°C 0.3°C
10 Screen display 0: room temp.1: set temp. 0
11 Child protection 0: keys unlocked 1: keys locked 0
12 Open window detection 1: On0: Off 0
13 The time interval in which the sudden drop in temperature is detected 2~30 min. 15 min.
14 Degrees lost in the time interval set at menu 13 2°C 3°C 4°C 2°C
15 The time after which the device returns to its original mode of operation 10~60 min 30 min.
17 Reset 0: No 1: Yes. Press for 5 seconds. 0
Software version

Connection diagram

The connection of the receiver unit to a 230V power supply and to a heating system must be performed only by qualified personnel and only after prior consultation of the technical documentation of the thermostat and the heating system. The receiver unit has a relay type control (NO Normal Open and NC Normal Closed) without potential (non-energized) which executes the closing of a control circuit with a maximum current of 10A and a maximum voltage of 250VAC/DC. Find examples of connections with certain models of the heating systems at the end of the manual.

Connections examples

Ariston CLAS EVO SYSTEM

Ferroli DivaCondens 24/28

Vaillant Ecotec Pure

Simplified EU declaration of conformity

SC ONLINESHOP SRL declares that PNI CT60 Wireless Thermostat is in accordance with RED Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following website:
https://www.mypni.eu/products/8001/download/certifications

REFERENCE:

DOWNLOAD MANUALS:

PNI CT60 Wireless Thermostat User Manual

PNI CT60 Wireless Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago