PERRY

PERRY 1TP TE411/B DIGITAL THERMOSTAT User Manuals

PERRY 1TP TE411-B DIGITAL THERMOSTAT

TECHNICAL DATA

  • Supply voltage: 1/ B / Electronic
  • Type of action, disconnect and device: 1/ B / Electronic Relay with changeover contact NO / COM / NC
  • Type of output: Relay with changeover contact NO / COM / NC voltage free – max 5(2)A / 250 V
  • Output connection (load): 2 or 3 conductors
  • Inputs for “Reduction” control, remote: for voltage free contact
  • Wire section at terminals: min. 0,75 mm ÷ max. 1,5 mm
  • Insulation type: Class II
  • Protection degree: IP30
  • Pollution: Normal
  • Operating temperature limits: 0 °C ÷ +50 °C
  • Storage temperature limits: -10 °C ÷ +65 °C
  • Temperature adjustment range: +5 °C ÷ +30 °C
  • Temperature display range: – 5 °C ÷ +39 °C
  • Reduction temperature: – 4 °C from the set temperature (”Winter” operation) +4 °C from the set temperature (”Summer” operation)
  • Precision of reading of the temperature: ± 0,5 °C
  • Ambient temperature indicator resolution: 0,1 °C
  • Differential operation: t selectable: 0,3 °C – 0,5 °C – 0,7 °C – 0,9 °C
  • Thermal gradient: 1 °K/15 min
  • Reference standard for CE mark: LVD EN60730-2-9
  • (directives 73/23/CEE – 89/336/CEE): EMC EN60730-2-9

SIGNALS AND CONTROLS

Temperature display

  • Room temperature display
  • Temperature setting display

The display normally shows the detected room temperature. When setting the temperature with the knob, the display shows the set temperature; a few seconds after the end of the operation the room temperature is shown again. In mode the set temperature shown is the reduced temperature: “Reduction” -4 °C from the Winter/ set temperature (for Summer model: -4 °C on “ ” and +4°C on “ ”). Winter Summer

Blinking signals

Operation mode switch (according to model)

INSTALLATION GUIDELINES

Installation of thermostat: independent – fixed
Wall mounting

  • Install the thermostat at a height of 1,5 m ÷ 1,7 m from the floor, far from heat sources, air vents, doors or windows and anything else that could affect its operation.
  • Important: installation and electrical connections of devices and appliances must be carried out by skilled people and in compliance with current regulations.
  • The manufacturer declines any liability in connection with the use of products subject to special environmental and/or installation standards

FIXING BASE TO THE WALL

SWITCH MAINS SUPPLY OFF
Fix with screws the base of the thermostat to the back box (or to the wall), using the pairs of holes provided.

  • A- for round box (diam. 60mm) with claws
  • B- for round or square box (with screws)
  • C- for 3 spaces rectangular box (with screws)
  • D- knockouts allowing entry of wires (flexible only)

ELECTRICAL CONNECTIONS

SWITCHMAINS SUPPLY OFF

Connect 230 V power supply wires to the terminals

  • n° NEUTRAL
  • n° LINE

Connect the controlled device to the terminals:

  • n° common
  • n° normally open contact
  • n° normally closed contact

If you want to use remote selection of “ comfort” / “Reduction ” temperature, connect the exterior contact (potential-free – e.g.: from time switch) to the terminals and of the thermostat

Remote selection of “Comfort” or “Reduction – ” temperature

Comfort ” temperature = Open contact
Reduction ” temperature = Closed contact
N.B control is operational within one minute.

Note for the contractor
Make the electrical connections taking particular care in the event of surface mounting without box that the wires are correctly arranged and do not hinder a proper fit between the body and the base.

IN MULTIPLE INSTALLATIONS (offices, schools,houses)with a single, centralized “Reduction” control (es.: Time switch).

Thermostats supply voltage (230 V)

  • Connect NEUTRAL to all n° 6 terminals.
  • Connect LINE to all 7 n° terminals.

Inputs for “Reduction” control –

  • Connect terminals, ALL  A to terminal of the remote contact.
  • Connect terminals, ALL  B to terminal of the remote contact

TEMPERATURE DIFFERENTIAL VALUE SETTING
The thermostat operates in differential modes (ONOFF) with a modifiable differential value (factory-set to 0,5 °C).

Changing the differential: position the dip-switches, located on the back of the thermostat, for the required differential value.

FIXING THE THERMOSTAT TO BASE

Fit the body to the base Exert light pressure until you hear the click of the attachment hooks. To remove the device insert a smal screwdriver as a lever in the position corresponding to the attachment hooks

LIMITATION OF THE MAXIMUM ROOM TEMPERATURE

  • turn the knob to the 5 °C mark; then remove the knob
  • extract the JUMPER from its housing
  • Insert the JUMPER in the holes corresponding to the desired temperature
  • replace the knob, making certain it is positioned as before: 5 °C position coinciding with the index on the front of the case

REFERENCE:

DOWNLOAD MANUALS:

PERRY 1TP TE411-B DIGITAL THERMOSTAT User Manuals

PERRY 1TP TE411-B DIGITAL THERMOSTAT User Manuals

wpx_thermostats

Recent Posts

Free Money Online Casino No Deposit Canada

Free Money Online Casino No Deposit Canada However, and players have no control over it.…

2 weeks ago

Eureka Casino No Deposit Bonus Codes For Free Spins 2026

Eureka Casino No Deposit Bonus Codes For Free Spins 2026 Furthermore, and beginner-friendly as well.…

2 weeks ago

Top 10 Online Canada Casinos

Top 10 Online Canada Casinos Top 10 online canada casinos you can contact Easy Slots'…

2 weeks ago

2026 Canada Changes In Blackjack

2026 Canada Changes In Blackjack 2026 canada changes in blackjack an online casino reload bonus…

2 weeks ago

Mannheim Casino No Deposit Bonus Codes For Free Spins 2026

Mannheim Casino No Deposit Bonus Codes For Free Spins 2026 Don't miss out on this…

2 weeks ago

Slot Games For Real Money

Slot Games For Real Money I should start with a variety of gambling options, you…

2 weeks ago