Dear Customer, thank you for choosing our product.
The thermostat, suitable for all heating and/or cooling system, is fitted with a large and clear backlit display to keep all its functions under control in real-time. The fundamental feature is its easy-to-use menu navigation, which makes it extremely user-friendly despite its comprehensive range of functions. The thermostat is factory-set to adjust temperature in a Differential ON/OFF manner and hysteresis can be set from 0.2°C to 1.2°C to adapt to the thermal inertia of your specific installation. Alternatively, modulating Proportional operation may be selected with settable duration cycles (from 7 to 20 minutes): this system ensures the desired temperature is maintained more stable, increasing user comfort and is particularly suitable for installations with high thermal inertia such as, for instance, for underfloor radiant panels. The set temperature scale is in degrees Centigrade (Celsius) with the option to calibrate room temperature measurement by setting a correction value (from -3 to +3 °C). The thermostat can be connected to a separate remote controllable temperature probe (optional) which may then be set according to one’s installation needs: remote, floor, external. Special attention was devoted to energy saving: pausing for household cleaning, optional Set temperature (MAX/MIN) lock, adjustable anti-freeze temperature value, and control through an external contact (e.g. optional telephone programmer), are conducive to avoiding wasting energy with consequent savings. See the following pages for a description of these as well as of other features
WARNINGS!
FACTORY SETTINGS
The data entered in the thermostat called «FACTORY SETTINGS» refer to the operation defined as «Standard». The following chapters describe all customizable functions, in order to satisfy any ambient comfort need
FACTORY SETTINGS TABLE (default)
RESTORE «Installer RESET»
Restore many factory settings (default) RESTORE brings the thermostat back to factory settings with the exception of some items as shown in the table; to perform the operation follow the instructions in paragraph 11.13.
RESTART
Should the thermostat feature malfunction, wrong displays or other incorrect conditions, perform a «User reset». Simultaneously press for 4 secs. the menu and keys. The thermostat resumes normal operation.
Backlit display
Touching any key activates back-lighting, displaying the selection and navigation of the words , press the desired key within 6 sec. to vary the settings (touching any key reactivates a 6 secs. time-out).
DISPLAY FEATURES
DIMENSIONS
INSTALLATION EXAMPLE
Switch off mains power 230V~ to the device
Fasten the base of the thermostat with the screws supplied: to the wall, to the rounded or rectangular recessed box via the relatively paired holes A
Important: the installation and electrical connection of the devices and appliances must be implemented by qualified personnel and in conformity with current laws and regulations. The manufacturer declines all liability in connection with the use of products subject to special environmental and/or installation standards.
Examples of electrical connections
After having made the electrical connections:
All setting operations may be performed before fastening the device to the wall base; this means setting may be carried out while comfortably seated. The flashing ON indication with fixed winter or summer symbol and the item NO RELAY indicates that the thermostat is detached from the wall base. Should the thermostat setting take place before fastening to the wall base, upon completing installation the ON indication (off or flashing) on the display might not correspond to the actual relay status. Within 1 minute at the most after fastening the thermostat to the wall base, the relay activates with the indication ON (off or flashing) displayed
SIGNALLING BATTERIES LOW OR DOWN
When the symbol blinks, this indicates that the batteries are running out and as from this moment, there are 15 days to replace them. Note: the backlight of the display is automatically deactivated. If the discharged batteries are not replaced within this time the display will completely turn off. All thermoregulation is suspended and all settings are saved to be restored when the new batteries are inserted.
INSERTING OR REPLACING BATTERIES
Unhook the thermostat from the wall base (see previous paragraph) Insert the batteries, respecting the polarity. Hook and fix the thermostat to the wall base (see previous paragraph)
Upon the first insertion of the batteries, the thermostat performs a lamp test by switching on all display segments, displaying the installed software version for a few seconds. When this phase is over, the thermostat asks to select the language of use
The thermostat is operative, displaying: Winter «heating» mode, the temperature Set at 20°C COMFORT, and room temperature detected. From normal thermostat operation in standby, pressing a key lights up the display (unless back-lighting has been disabled) and the selection and navigation of the words appear. Within 6 secs., a variation is made the second time the desired key is pressed.
USE OF THE THERMOSTAT
Press the
MODIFICATION OF T Set TEMPERATURE SET
Directly press the
In the presence of max and min. temperature locks (see paragraph 11.6) it is not possible to set a Set t higher or lower than the entered locks. The display will signal the impossibility to perform the operation by displaying
TEMPERATURE CONTROL PAUSE (example for household cleaning)
Pressing the key connected user will switch off for a max 3- hour period during which the thermostat will enter antifreeze mode ( t ). After 3 hours the thermostat temperature control will resume. It is possible to restart temperature control before the 3 hours have elapsed, press «back»: theword «CLEANING» disappears.
Note: in the event antifreeze temperature has been permanently disabled or in “Summer” operation, the connected user (e.g. boiler or air conditioner) will remain disabled for 3 hours maximum
OFF (disabling the thermostat)
STRUCTURE OF THE MAIN MENUS (use and configuration)
From normal thermostat operation, press the Menu key for 3 secs. to access the first available menu.
SET WINTER OR SUMMER MODE
MODIFICATION OR DISABLING OF SET ANTIFREEZE TEMPERATURE
To disable antifreeze temperature, go below+5.0 °C (41.0 °F).
Password modification or cancellation
Press MENU for 3 secs., and enter the previously set password; follow the procedure described above to access the User PASSWORD SEtmenu:
ACCESS TO THE CONFIGURATION MENU
From normal thermostat operation, access the menus by pressing and holding the «Menu» key.Select with the
CHANGESET LANGUAGE
The selectable languages are: ITALIAN=It (default), ENGLISH=En, FRENCH=Fr, GERMAN=dE, SPANISH=ES.
TYPE TEMPERATURE ADJUSTMENT METHODS
Note: adjustable from 0,2 °C to 1,2 °C (from 0,3 °F to 2,1 °F).
CHANGE UNIT OF MEASURE FOR TEMPERATURE READING
The thermostat is pre-set in the factory to display temperatures in degrees Centigrade (Celsius), it is possible to switch to the Fahrenheit scale or vice versa with the following procedure
CORRECTION OF ROOM TEMPERATURE READING
If for any reason the thermostat must be installed in a position where the measured room temperature might be affected (e.g. perimeter wall which is on average colder in winter and warmer in summer than the rest of the dwelling) the device has 2 separate parameters to adjust the room temperature measured in the Winter and Summer modes.
OFFSET for winter mode( )
MAX AND MIN SET TEMPERATURE LOCK (Winter and Summer mode)
In certain thermostat installations (public buildings, hotels, etc.) it might be useful to limit the maximum and minimum temperature set points. This avoids incorrect settings by unauthorized personnel (energy savings). It is possible to limit (lock) the maximum, minimum, or both temperature values settable on the thermostat. The restriction may be applied either to the Winter or summer mode.
General rule
PROBE MENU
In addition to the internal probe of the thermostat, it is possible to connect to terminals 6 and 7 «AUX 1» (see wiring diagrams in ch. 5.4) a supplementary probe (optional) which may be set to read temperature in various modes. Press for 3 secs. the key Menu, and through the path ->CONFIGUR SEt ->PROBE SEt, press OK to enter the menu. Selectable functions are as follows
Select the desired type of probe with the keys and confirm with OK.
NO CONNECTION TO SEPARATE PROBE
Should you wish to disable the previously active separate temperature probe and go back to using the standard internal one (default), follow this procedure: key Menu down for 3 secs. and through path -> CONFIGURE SEt ->PROBE SEt ->select itemPROBE nO (NO) and press OK to confirm. Press the back key to exit.
SETTING SEPARATE REMOTE PROBE
This is a remote probe to detect the temperature in a different room from the one where the thermostat is installed, for instance in the event of unfavorable installation or in premises unsuitable to reading and adjusting the temperature. The remote probe has the same parameters and reading range as the internal probe. Reading range: -5.0°C÷+37,7°C (+23°F÷+99,9°F). It completely replaces the internal thermostat probe and the product will control room temperature through this remote probe. After connecting the remote temperature probe to the thermostat, it may be activated through the path: Menu key for 3 secs. ->CONFIGUR Set ->PROBE SEt ->select itemREMOTE. Press «OK» to confirm. Press the back key to exit
SETTING FLOOR PROBE
This is a separate and remote controllable temperature probe, buried in the screed of an underfloor heating system with radiating panels, to monitor the temperature and turn off the system in case the temperature read exceeds a pre-set threshold value. After connecting the separate temperature probe to the thermostat, it may be activated by holding down the Menu key for 3 secs.->CONFIGUR SEt ->PROBE SEt ->select item FLOOR. Confirmwith the OK key.
The thermostat displays and controls the room temperature detected by the internal probe:
at the same time the separate probe also detects the floor temperature, which will be compared with the threshold set by the installer, to prevent this temperature from exceeding the safety threshold. Should this occur the thermostat will switch off the system even if Set t temperature is not reached; the display signals this condition by displaying the code tP and the set threshold value flashes
SETTING SEPARATE EXTERNAL PROBE
This is an additional probe to read the temperature outside the dwelling (tE). It does not have any home temperature control features, which are controlled by the internal thermostat probe After connecting the external temperature probe to the thermostat, it may be activated by pressing the Menu key for 3 secs. and through the path CONFIGUR SEt ->PROBE Set ->select itemEXTERNAL. Press «OK» to confirm. Press the back key to exit External probe reading range:: – 9.9°C ÷ +60.0°C (+14.2°F ÷+140.0°F).
CONNECTION TO EXTERNAL CONTACT FOR REMOTE THERMOSTAT SWITCHING ON/OFF
A remote device may be connected to the thermostat (e.g. telephone programmer, hourly switch, switch) able to remotely enable/disable the thermostat. From normal thermostat operation, access the menus by pressing and holding the key for 3 secs. «Menu» and through the path CONFIGUR SEt ->, select itemINPUT SEt. PressOKto confirm. Various operation modes may be selected depending on the type of contact free from potential (NO or NC) and type of device connected to the terminals 8 and 9 «AUX 2» (see par. 5.4 electrical connections )
ACTIVATION / DISABLING WITH A TELEPHONE PROGRAMMER
After connecting the Telephone programmer (optional) to the thermostat, it will be possible to select the nC (normally closed contact) or nA ( normally open contact «NO») contact type setting on the telephone programmer. Press the Menu key for 3 secs. and through the path, CONFIGURE SEt ->display item INPUT SEt, press «OK» and with keys choose item PHONE nC or PHONE nA. Press «OK» to confirm. Press the back key to exit.
Example of remote thermostat switching on/off, connected to a telephone programmer with «nA» contact (NO normally open)
Programmer contact closure (change of state): causes temperature t1 COMFORT override and displaying associated symbols/setpoints and the steady icon “ ” indicating incoming telephone override. After that it will be possible to change the operation mode on the spot by manually acting on the thermostat keypad, even if the telephone programmer contact remains closed; the icon “ ” it will remain on (steady), indicating that the contact is still closed.
Programmer contact opening (change of state): causes operation status override OFF (par. 7.4 – Thermostat disabling)with antifreeze function unless it is disabled; the display shows OFF (steady) and icon “ ” flashing, indicating incoming telephone override. After that itwill be possible to go back to normal thermostat operation by pressing the key , the icon “ ” will go out indicating the end of telephone override.
«nA» DUTY – for normally open contact (NO)
By selecting this function it is possible to connect a NO remote contact which upon closing sets the thermostat in the OFF mode with antifreeze temperature t , unless it has been previously disabled. In this condition, it will not be possible to act on the thermostat keys to change the operation status. Open the contact and the thermostat resumes operation mode active before overriding. Press the Menu key for 3 secs., follow the path CONFIGUR SEt ->INPUT SEt ->select items DUTY. Press «OK» to confirm. Press the back key to exit.
«nC» DUTY – for normally closed contact (NC)
By selecting this function it is possible to connect an NC remote contact which upon opening sets the thermostat in the OFF mode with antifreeze temperature t , unless it has been previously disabled. In this condition itwill not be possible to act on the thermostat keys to change operation status. Close the contact and the thermostat resumes operation mode active before overriding. Press theMenu key for 3 secs., follow the path CONFIGURE SEt ->INPUT SEt ->select items DUTY. Press «OK» to confirm. Press the back key to exit the DESCALING CYCLE
DISPLAY CONTRAST ADJUSTMENT
8 adjustment levels are available. Level 6 is set in the factory. From normal thermostat operation, press the Menu key for 3 secs., follow the path CONFIGURE SEt ->use
BACKLIGHTING
It lets you enable or disable timed display backlighting. From the normal operation of the thermostat press the Menu key for 3 secs., follow the path CONFIGUR SEt ->use
Press OK to confirm. With the keys
ENTERING AND MANAGING PASSWORDS
Some functions of the thermostat may be protected by a user Password (Ut) and/or an installer (Inst), so that they may be only modified by authorized persons. No password is active in factory settings.
ENTERING THE NEW PASSWORD
PASSWORD MODIFICATION OR CANCELLATION
When required, enter the previously created User or Installer password; follow the above procedure and access itemPASSWORD SEt Ut or InSt : – enter 4 hyphens (- – – -) to cancel the password – enter 4 new digits to modify the password
SYSTEM SOFTWARE INFORMATION
DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT
DOWNLOAD MANUALS:
PERRY 1TP-TE028B DIGITAL THERMOSTAT INSTRUCTION MANUALS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…