WARNING
CAUTION
MOUNTING THE THERMOSTAT
The thermostat mounts to a 4×4 box with a 2×4 mud ring.
System Button Operation
OFF All thermostat outputs are off.
AUTO The thermostat automatically selects the heating or cooling mode depending upon the set point and room temperature. The appropriate HEAT or COOL icons are illuminated if demand exists. A 3°F dead-band is provided to prevent short cycling between heating and cooling modes. After the changeover, the control point automatically shifts so that the control-off point equals the set point temperature.
F/C Button Operation
This button toggles from Fahrenheit to Celsius.
Speed Button Operation
Some models have a Speed button instead of an F/C button. Fan speed is determined by the manual selection of HI or LO. Holding this button in for 5 seconds will toggle the displayed temperature from Fahrenheit to Celsius.
HVAC SETBACK SYSTEMS
Install jumper JP3.
The T170 can be used with the PECO S200 series occupancy detection equipment. The occupancy and door switch inputs are designed to connect to the SB200 slave sensor and SE200 door switch. The Occupancy sensor switch is open when there is occupancy and closed when unoccupied. The Door Switch is open when the door is open and closed when the door is closed. This system requires both an Occupancy Sensor and a Door Switch. The operation is as follows:
FROM OCCUPIED MODE:
FROM UNOCCUPIED MODE:
In either mode, if the door is left open for more than 2 minutes the T170 will disable the HVAC system. A one-time ten-minute override can be initiated by pressing any thermostat keypad.
In an Occupied State, the thermostat operates normally and looks for a door close. In the Unoccupied State, the thermostat sets heating and cooling set points to setback values, as determined by factory or user settings. In this mode, the fan is automatically set to cycle with demand. The T170 will continue to monitor the occupancy sensor and will go to the occupied state anytime occupancy is detected.
Setback Operation
Remove jumper JP3. This is a low-level switch input that is normally open. When closed the T170 Heating and Cooling setback limits are used as temperature control points. Fan operation in the setback is cycled with demand. Pressing any button will override the setback for 1 hour. The setback will override any user setting except if the control is turned to OFF. Units with a controlled off-factory setting will override the OFF setting. Intelligent occupancy sensors like the SD200-001 and SD200-002 can be used with this input to set the HVAC system to control at setback limits.
Door Switch Only Operation
Install jumper JP3.
A stand-alone door switch can be connected to the T170 to disable the HVAC system if the door is left open for more than 2 minutes. A one-time ten-minute override can be initiated by pressing any thermostat keypad.
CONDENSATE OVERFLOW INTERRUPT
The remote probe input can be used with a condensate overflow switch (CO), either in conjunction with a remote probe (normally closed CO switch) or with local sensing (normally open CO switch). When condensate switch activates, the T170 will display the service wrench and disable all outputs.
FAN OPERATION
Your thermostat can be d for up to two fan speeds. Fan staging follows the Heat and Cool Staging Separation. Heat and Cool staging can be user selected to different values. The FAN button is used to select FAN AUTO or ON. In the Auto position the fan cycles on with the demand for heating or cooling. If ON is selected the fan will run continuously.
CONTROLLED OFF
FACTORY CONFIGURATION
A factory configuration may be provided to ensure minimum heat and cool requirements. With this configuration, the heat and cool outputs are automatically cycled on at the heat and cool setback limits. Your thermo-stat may not have this feature.
WIRING DIAGRAM
OUTPUT RA TINGS | ||
INPUT VOLTAGE | VOLTAGE | PILOT DUTY |
24 VAC | 24 VAC | 24 VA |
OUTPUT CONFIGURATION
A table is provided on the inside of the base to document the function of various outputs. The function of configurable outputs should be filled in when the unit is installed.
JP4 JUMPER SELECTION
This jumper is temporarily installed at initial power up to outputs 3 through 6. See Output Configuration.
JP3 JUMPER SELECTION
This jumper is shipped normally open. Placement of a jumper onto both pins allows for Occupancy Detection/ Door switch and Door Switch Only Operation.
JP1 JUMPER SELECTION
Removing this jumper allows the sensor to be located in a remote location. Accessory remote probe sensors are available in standard lengths but can be extended to meet application requirements.
SERVICE MENU
Access to the Service Menu:
Continuous Set Point Display
At this feature, either the F or C icon and the SETPOINT icon will be displayed. If the Continuous set point display is enabled the SETPOINT icon will flash. The Up or Down Arrow button will toggle between a continuous display of set point and a display of zone temperature.
Fan Off Delay
The FAN, OFF and digits are displayed. Digits represent the number of seconds the fan will stay on after the heating and cooling outputs are turned off. The Up or Down Arrow button can be depressed to increase/decrease value from 0-255 seconds.
Range Limit LO
The display reads the current minimum range setting, SETPOINT icon, and LO icon. The Up or Down Arrow button can be depressed to increase/decrease value..
Range Limit High
The display reads the current maximum temperature range adjustment, SETPOINT icon, and HI icon. The Up or Down Arrow button can be depressed to increase/decrease value.
Setback Heat
The display reads the current temperature range adjustment, the SETBACK icon, and the HEAT icon. The Up or Down Arrow button can be depressed to increase/decrease value.
Setback Cool
The display reads the current Cool setback value, the SETBACK icon, and the COOL icon. The Up or Down Arrow button can be depressed to increase/decrease value.
Zone Temperature Offset
The display reads ones and tenths (0.0) with leading minus sign. The Up or Down Arrow button can be depressed to increase/decrease value +/- 9F. Increments are made in 1F and 0.5C.
Keypad Lockout
The ON and OFF icons are displayed. The enabled icon is flashing. OFF is the default. ON disables the keypad except for entry into the service menu. The Up or Down Arrow button can be depressed to select the mode.
Heat Stage Separation
The AUX, HEAT, and current separation icons are displayed. The value can be changed from 0-12F using the Up or Down buttons.
A- Cool Stage Separation
The AUX, COOL, and current separation icons are displayed. The value can be changed from 0-12F using the Up or Down buttons.
Note: These values are stored and recalled in the event of a power failure.
OUTPUT CONFIGURATION MENU
Four of the six TC170 relay outputs can be field configured for heat stag-ing, cool staging, up to 2 fan speeds and a single outside air damper. Heat stage 1 and Fan low are permanently configured at the factory. The user is allowed to assign the remaining outputs. Your specific thermostat may come with a custom configuration for outputs 3-6. These can be reconfigured in the field.
Output Configuration
Assigning an output is accomplished as follows:
CO1 HEAT STAGE 2 HEAT and MED
CO2 HEAT STAGE 3 HEAT and HI
CO3 COOL STAGE 1 COOL and LO
CO4 COOL STAGE 2 COOL and HI
CO5 FAN HIGH FAN and HI
CO6 OUTSIDE AIR AUX and FAN
Use the UP/DOWN arrows to select the output number to be assigned. See Output Designations below.
Output
NO. Wire Color Configuration
Push/ Select the F/C key to assign the output to the menu item
The associated relay will energize when the output is assigned. Note: If you do not push the F/C key the output will not be assigned. When a function is assigned to an output, any previous functions that were assigned to that output will be disabled and become unassigned. When the configuration is complete turn the power off and remove JP4. The unit is now ready for operation and checkout.
NOTE: With JP4 installed no other control operation is available.
Download Manual:
PECO TC170 STAGING THERMOSTAT Installational Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…