The CSQ-TRV is a battery-powered, mini-size thermostatic radiator valve (TRV) controller using ZigBee wireless communication. Simply replace the existing, passive head on the standard radiator valve with the CSQ-TRV (referred to from now on as the unit). Use the unit with the CSQ-RFW/STAT series of wireless thermostats and a CSQ-GATEWAY
Product Compliance
This product is CE compliant and meets the following EC Directives: Electro-Magnetic Compatibility directive 2014/30/EU; 2014/53/EU and 2011/65/EU.
Safety Information
Use in accordance with the regulations. The unit is to be used for the control of room temperature inside the house.
This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
To achieve the best control from the unit and thermostat, we recommend they are used with the OMNIE system receiver configured to RX1. The system receiver will turn the boiler on or off when requested by the thermostat. See your boiler receiver manual for more information about the RX1 configuration
Checking the compatibility of your heating system
The OMNIE CSQ-TRV is compatible with the majority of thermostatic radiator valves. Before fitting, please check your valve is suitable for use with the OMNIE TRV.
Checking the compatibility of your heating system
Installing the Unit
Pairing the Unit
Note: After you have deleted the unit from the wireless network, you must reinstall the TRV see Installing the unit.
Auto Lock Function
Auto lock function is disabled until you have gone through the pairing process. After pairing, the TRV will auto lock after 5 minutes if no buttons have been pressed.
Unlocking the Buttons
To unlock the buttons, press the pairing and close buttons together for 3 seconds.
Opening the Valve Manually
Press the open button for 3 seconds. The LED flashes green once and the valve opens.
Closing the Valve Manually
Press the close button for 3 seconds. The LED flashes red once and the valve closes.
Entering Fail-Safe Mode
In fail safe mode, the unit opens the valve 25% for water flow to maintain room temperature. To enter fail-safe mode, press and hold the open and close buttons together for 3 seconds. To exit fail safe mode, press the:
Restoring Factory Default Settings
Press the pairing, open, and close buttons together for 10 seconds.
Protecting against Frost
When you have manually closed the valve, the unit automatically enables frost protection. Frost protection starts only when the temperature in the room drops below the frost temperature setpoint. The unit does all this automatically when connected to a thermostat and you don’t have to do anything.
Detecting Open Windows
The unit checks the rate of temperature drop in the room in which it is located. If the drop is rapid, it assumes a window in the room has been opened. This only works if the unit is paired to the thermostat and is in automatic mode and the battery in the unit is not low. The unit does all this automatically when connected to a thermostat and you don’t have to do anything. It works between 0 and 40⁰C.
Protecting against Lime Scale
Do not leave a valve open for a long time because this could cause a build up of lime scale. The unit has a lime-scale protection feature to prevent against this. The valve motor automatically starts once a week if no valve movement has been detected within a 14- day period. Lime-scale protection will continue to operate in automatic, manual open, and manual close modes and you don’t have to do anything.
Auto Adaptation
Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed it will auto adapt to the valve
Button Usage
To do this… | Press the… |
Leave the network | Pairing button for 10 seconds (when unit already in network) |
Pair with thermostat | Pairing button for 10 seconds |
Put unit in automatic mode | Short press Pairing button |
Fully open the valve | Open button for 3 seconds |
Fully close the valve | Close button for 3 seconds |
Restore factory default settings | Open, pairing, and close buttons together for 3 seconds |
Lock and unlock the buttons | Pairing and close buttons together for 3 seconds |
LED Indications
When… | The LEDs… | Valve | |
Power switched on or after reset | Software Version indication | A sequence of red and green LEDs flashing displayed indicates the software version | |
Unit adapting to valve | Red flashes then goes steady. Green flashes (or red flasheson failure to adapt). Green steady. Green and red flash (or red flashes on failure to adapt) | ||
Unit has not joined network or has not paired to thermostat | Auto mode | Green and red flash alternately after short press on open or close button | 25% open |
Manual open | Green flashes twice after short press on open or close button | 100% open | |
Manual close | Red flashes twice after short press on open or close button | 0% open | |
Unit paired to thermostat and in auto mode | No LED | ||
Leaving network | Red and green on together for one second | ||
Identifying the network | Green flashes for up to 10 minutes | ||
Wireless link to thermostat lost | Auto mode | Green and red flash alternately after short press on open or close button | |
Manual open | Green flashes twice after short press on open or close button | 100% open | |
Manual close | Red flashes twice after short press on open or close button | 0% open | |
Normal operation | Auto mode | Green flashes once after short press on open or close button | 1 to 100% open |
Auto mode | Red flashes once after short press on open or close button | 0% open | |
Manual open | Green flashes twice after short press on open or close button | 100% open | |
Manual close | Red flashes twice after short press on open or close button | 0% open | |
Window open mode active | Green and red flash twice every 10 seconds | 100% open | |
Battery low | Red flashes three times every 10 seconds (less if the battery is low) | 25% open | |
Error installing | Green and red flash alternately |
To remove the unit from auto mode, follow the steps below. If the buttons are locked, unlock them by pressing the pairing and close buttons together for 3 seconds.
Model | CSQ-TRV |
Type | Hydraulic Radiator Valve DC Motor M30 x 1.5 |
Input | Three push buttons: • Manual open/status indication • Manual close/status indication • Pairing |
LED Indicator | Bi-Colour, Red/Green |
Valve Adaptation | Automatic |
Power Source | 2x AA Batteries |
Battery Life | 14 Months (low battery indication) |
Control Method | Modulating |
Communication | 2.4GHz ZigBee wireless |
Operating Temperature | 0 to 45ºC |
Storage Temperature | -20 to 60ºC |
Operating Humidity | 5 to 95”RH |
Protection | IP30 |
Size (mm) | H 88.6, W 51 |
OMNIE warrants that this product will be free from any defect in materials and shall perform in accordance with its specification, for a period of five years from the date of installation. OMNIE sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
DOWNLOAD MANUALS:
OMNIE CSQ-TRV Radiator Thermostat Installation Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…