The thermostat is an electronic PWM/PI thermostat for temperature control by means of an NTC sensor located either externally or internally within the thermostat. The thermostat is for flush mounting in a wall box. A baseplate for wall mounting is also available. This thermostat can be used as a controller for electric room heating pursuant to EN 50559.
CONTENTS
To avoid electric shock, disconnect the heating system power supply at the main panel before carrying out any work on this thermostat and associated components. Protection against electric shock must be guaranteed by appropriate mounting. The requirements of Class II are fulfilled after appropriate mounting (reinforced insulation). Installation must be carried out by qualified personnel in accordance with appropriate statutory regulations (where required by law). Installation must comply with national and/or local electrical regulations.
Caution
This instruction must be observed, otherwise, the liability of the manufacturer shall be voided. Any changes or modifications made to this thermostat shall void the liability of the manufacturer. Maximum product lifetime is achieved if the product is not turned off but set at the lowest possible set point/frost protection when heat is not required.
Notice
The language used in the original documentation is English. Other language versions are translations of the original documentation. The manufacturer cannot be held liable for any errors in the documentation. The manufacturer reserves the right to make alterations without prior notice.
PLACEMENT OF THE THERMOSTAT
The thermostat should be mounted on the wall approx. 1.5 m above the floor in such a way as to allow free air circulation around it. Draughts and direct sunlight or other heat sources must be avoided.
OPENING THE THERMOSTAT
Activated by a 230V signal, possibly through an external control, clock, or timer connected to the S terminal.
ON/OFF: To turn the thermostat ON, open the front cover, and push the ON/OFF switch up (left side of the thermostat).
Settings: Press ”
Factory reset: Press ”
Schedule: Press ”
Child lock: Press ”
Manual override: To activate or deactivate manual override, quickly press and release ”
Navigation: ”
Settings | Options | Factory setting | |
CLc (Clock) | 00:00 – 24:00 | 00:00 | |
Day (Day) | Mon, Tue, WEd, Thu, Fri, Sat, Sun | Mon | |
5chE (Schedule) | 5-2, 6-1, 1E2, 1E4, 7E4 | 5-2 | |
Lcd1 (Lcd) | Set, CLC, — | CLC | |
Lcd2 (Lcd) | Set, tP | Set | |
rCt (Remote controlled temp.) | 5°C – 25°C | 10°C | |
OPEn (Open window) | On/Off | On | |
AdAP (Adaptivestart) | On/Off | On | |
Adj (Adjust) | -9.9°C – +10°C | 0°C | |
-5U (Software Version) | Readout value | Readout value | |
-FtP (Floor temp.) | Readout value | Readout value | |
-RtP (Room temp.) | Readout value | Readout value | |
PLi (Power Limit) | 0-30 | ||
PuL5 (Pulse Width Modulation) | About | CYHi: 10-60 CYLo: 10-30 | 30 15 |
Off | Diff: 0.3°C – 10°C | 0.4 | |
On | CYcL: 10-60 | 30 | |
FLLo (Floor limit low) | 0°C – 40°C | 15°C | |
FLHi (Floor limit high) | 0°C – 40°C | 27°C | |
tLLo(Temp.limit low) | 0°C – 40°C | 0°C | |
then (Temp. limit high) | 0°C – 40°C | 40°C | |
APP (sensor application) | R | Room |
rF |
F | Floor | ||
C | Regulator | ||
RF | Room w. floor limits | ||
RE | External room sensor | ||
donE (Done) |
The thermostat is maintenance-free. Keep the air vents of the thermostat clean and unobstructed at all times. The thermostat must only be cleaned with a dry cloth.
Regulations
OJ Electronics A/S hereby declares that the product is in conformity with the following directives of the European
Parliament:
Applied standards and approvals
Classification
Protection from electric shock must be assured by appropriate installation. Must be installed according to the requirements of Class II (reinforced insulation).
Protect the environment by disposing of the package in compliance with local regulations for waste processing.
Recycling of obsolete appliances
Equipment containing electrical components must not be disposed of along with domestic waste. It must be separately collected together with electrical and electronic waste in accordance with current local regulations.
Purpose of control | Electrical underfloor heating |
Mounting method | Flush or surface mounted |
Supply voltage | 230-240VAC, 50/60 Hz |
Max. pre-fuse | 16 A |
Built-in circuit breaker | 2-pole, 16 A |
Enclosure rating | IP 21 |
Wire size, terminals | Current ≤ 13 A – 1.5 mm2, solid core wire Current > 13 A to 16 A – 2.5 mm2, solid core wire |
Output relay | Max. 16 A / AC 230V |
Output, load | Max. 16 A / 3600 W |
Control principle | PWM/PI* |
Standby consumption | ≤0.75 W |
Dimensions | 84mm (H), 84mm (W), 40mm (D)Installation depth <20mm Weight ≤150 g |
Display | 21 x 21mm LCD |
Control pollution degree | 2 |
Overvoltage category | III |
Type of action | 1.B |
Software class | A |
Rated impulse voltage | 4kV |
Ball pressure-temperature (TB) | 125°C |
EU registered design | DM/089 338 |
Advanced control without any hysteresis.
The trademark is registered and belongs to OJ Electronics A/S · © 2022 OJ Electronics A/S
DOWNLOAD MANUALS:
OJ ELECTRONICS MCD3 Digital thermostat Instruction Manual
OTHER MANUALS:
OJ ELECTRONICS MCD3 Digital thermostat Product Specifications Guide
OJ ELECTRONICS MCD3 Digital thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…