MOUNTING OF WALL MOUTING PLATE
For best performance, do not mount the timer on metal wall boxes and leave at least 30 cm distance from any metal objects including wall boxes and boiler housing. The digital timer is fixed on the wall with the wall plate which is supplied with the product.
All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this timer consult either with a qualified electrician or heating Engineer. Do not remove or refit the appliance onto the backplate without the mains supply to the system being isolated. All wiring must be in accordance with IEE regulations. This product is for fixed wiring only.
Internal wiring
Standard Connection to Combi Boiler
(with Service shut-down if enabled of heating only)
Connection to Combi Boiler
(with Service shut-down if enabled of both heating & hot water)
On the wall
On the table stand
Recommended locations for your room thermostat.
To ensure that your room thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc.
NB: In order to ensure proper operation of the product, ensure that the room thermostat is not positioned near to an area which could be affected by interference from another source. E.g.: a wireless transmitter or receiver, TV, PC, etc.
Important: The room thermostat measures the temperature of the place where it is installed.
It does not take into account the temperature differences that may exist between different locations in the house if the temperature is not uniform.
PAIRING PROCEDURE
The room thermostat and the timer are not bonded together at the factory. To bond the transmitter and the timer together, proceed as below:
PLEASE READ BEFORE PROGRAMMING YOUR THERMOSTAT
WHAT IS OPTIMISATION – OPTIMUM START?
Historically, most UK heating systems waste vast amounts of energy by firing unnecessarily early for most of the year. Homeowners tend to set their boiler on times based on when they wake up by guessing what time they feel that their boiler should fire in order to reach the requested target temperature; for example turning the boiler on at 6am in order to have a warm room/ home by their wake up time at 7am.
Optimization function, priority to comfort: Depending on various parameters: room inertia, ambient temperature, desired temperature, the thermostat calculates and optimizes the programming for each heating period:
In OPTI mode, priority to comfort
In OPTI mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum comfort during the COMFORT programme.
The processor within the thermostat starts the boiler operation at the optimum time to achieve the setpoin temperature at the start of the occupancy period.
In this mode, the priority is given to anticipating and maintaining the comfort temperature periods of occupancy. Instead of using a fixed start time, Optimum Start calculates how long the house will take to warm up depending on the temperature of the home, then fires the boiler automatically at the most efficient moment in order to reach your target temperature by your programmed time.
HOW DOES OPTIMUM START WORK?
Optimum Start works on a daily basis. You set the time that you want to be warm and Optimum Start will do the rest; for example – if you wake up at 7:30AM, then set your thermostat’s start time for 7:30AM. Optimum Start ensures that you are warm when you want to be (and not before), reducing wasted energy and saving money (up to 10% of energy costs).
When the product is in an optimisation period, the or will blink until the beginning of the on/off or time.
To able on/off enable the optimisation, refer to the installation instructions/ advanced installer settings.
Access
Move the mode slider to off position.
Move the programming slider to position.
Press simultaneously and- and Review for 5 seconds.
7 advanced settings can be modified.
Press until correct option is in display then use or to select your choice.
Setting number Description
Set 12/24 hours clock (2)
The pre-set value is 12 hours clock.
Auto Summer/Winter change over (3)
The auto Summer/Winter change over default is ON.
Set number of ON/OFF periods (4)
You can adjust the number of ON/OFF switching time periods. The pre-set number is 2.
Installation operating (5)
The digital timer can manage Central Heating or 1 zone. The pre-set choice is CH.
Backlight (6)
The backlight can be switched Off. The pre-set value is ON.
Optimization (7)
The optimization can be switched Off; the pre-set value is ON.
Type of control (8)
The type of control can be switched to 2 points; the pre-set value is TPI.
Note regarding the Advanced installer settings: If programming slider is moved, it will save changes and exit installer mode.
Timer
Environment:
Maximum range in the home:
15m is typical but this varies depending on the building construction E.g. plasterboard lined with metal foil, the number of walls and ceilings that the signal has to pass through, and by the surrounding electromagnetic environment.
Signal sending:
Every 10 minutes, maximum time lag 1 minute after setpoint temperature has been changed.
Environment:
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2017 No. 1206 (Radio Equipment Regulations), 2012 n°3032 (ROHS) and following designated standards listed below:
Neomitis Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
contactuk@neomitis.com
EU declaration of conformity: We, Imhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below:
Imhotep Creation: ZI Montplaisir – 258 Rue du champ de courses – 38780 Pont-Evêque – France –
contact@imhotepcreation.com
Neomitis Ltd and Imhotep Creation belong to Axenco Group.
The symbol, affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.
Download manual:
NEOMITIS TMR7RFa DIGITAL THERMOSTAT INSTALLATION INSTRUCTION
OTHER MANUALS:
NEOMITIS TMR7RFa DIGITAL THERMOSTAT OPERATING Instruction
NEOMITIS TMR7RFa DIGITAL THERMOSTAT INSTALLATION INSTRUCTION
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…