Recommended locations or your thermostat.
To ensure that your thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold
draughts, etc.
Important: The thermostat measures the temperature of the place where it is installed.
It does not take into account the temperature differences that may exist between different locations in the house if the temperature is not uniform.
For best performance, do not mount the thermostat on metal wall boxes and leave atleast 30 cm distance from any metal objects including wall boxes and boiler housing.
MOUNTING OF WALL MOUNTING PLATE
The digital room thermostat is fixed on the wall with the standard wall plate which is supplied with the product.
All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this thermostat consult either with a qualified electrician or heating Engineer. Do not remove or refit the thermostat onto the backplate without the mains supply to the system being isolated.
All wiring must be in accordance with IEE regulations. This product is for fixed wiring only.
NOTE: The unit is double in insulated so does not require and earth but a terminal is supplied for the spare wire.
PLEASE READ BEFORE PROGRAMMING THE THERMOSTAT
WHAT IS OPTIMISATION- OPTIMUM START?
Historically, most UK heating systems waste vast amounts of energy by firing unnecessarily early for most of the year. Homeowners tend to set their boiler on times based on when they wake up by guessing what time they feel that their boiler should fire in order to reach the requested target temperature; for example turning the boiler on at 6am in order to have a warm room/ home by their wake up time at 7am.
Dual function optimisation, priority to comfort or energy savings, the choice is yours: Depending on various parameters: room inertia, ambient temperature, desired temperature, the thermostat calculates and optimises the programming for each heating period whether set to Comfort or Savings (Eco):
In OPTI COMFORT mode, priority to comfort
In OPTI COMFORT mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum comfort during the COMFORT programme.
The processor within the thermostat starts the boiler operation at the optimum time to achieve the setpoint temperature at the start of the occupancy period.
In this mode, the priority is given to anticipating and maintaining the comfort temperature during periods of occupancy.
In OPTI ECO mode, priority to energy savings
In OPTI ECO mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum energy savings throughout the ECO programme.
In this mode, a slight drop in the temperature level at the beginning and end of the comfort period is allowed to maximise energy savings.
PLEASE READ BEFORE PROGRAMMING THE THERMOSTAT
Instead of using a fixed start time, Optimum Start calculates how long the house will take to warm up depending on the temperature of the home, then fires the boiler automatically at the most efficient moment in order to reach your target temperature by your programmed time.
HOW DOES OPTIMUM START WORK?
Optimum Start works on a daily basis. You set the time that you want to be warm and Optimum Start will do the rest; for example – if you wake up at 7:30AM, then set your thermostat’s start time for 7:30AM. Optimum Start ensures that you are warm when you want to be (and not before), reducing wasted energy and saving money (up to 10% of energy costs).
To change the optimisation type, refer to the installation instructions/ advanced ins- taller settings.
Access
Slider position | Installer mode access |
1 | Set 12 or 24 hours clock |
2 | Enable/disable automatic summer/winter change |
3 | Set °C/°F temperature unit |
4 | Set calibration of the temperature displayed |
5 | Program lock |
6 | Select the type of control: 2 points or TPI |
9 | Optimization choice |
SET 12/24 HOURS CLOCK
The pre-set value is 12 hours clock.
ENABLE/DISABLE AUTOMATIC SUMMER/WINTER CHANGE OVER
The summer/winter change will be performed automatically by the room thermostat.
SET C/F TEMPERATURE
The pre-set temperature is Celsius (C).
Important: This operation is reserved for professional installers only; any wrong Oroa OJeJOI9 changes would result in control anomalies.
Change should only be made if the temperature measured (measured by a reliable thermometer) is different by at least 1″‘C compared to the setpoint temperature of the room
thermostat.
The calibration adjusts the temperature measured by the ambient temperature sensor to compensate for a deviation from +3°C to – 3*’C in increments of 0.5°C.
IMPORTANT: Before carrying out the calibration it is recommended to wait for 4h after a setpoint temperature modification to insure that the ambient temperature is
stabilized.
The pre-set calibration value is 0.
PROGRAM LOCK
The product is unlocked by default, OFF is displayed.
When program lock function is turned on then following functions will be disabled:
SELECT 2 POINTS/TPI
2 points = ON/OFF regulation. TPI = Proportional control algorithm.
The pre-set control algorithm is TPI.
Note regarding the Advanced installer settings: If MODE slider is moved or no press/rotation for 15 seconds, it will discard changes and exit installer mode.
Overview
Dual function optimisation, priority to comfort or energy savings, the choice is Prog O eJOl Run yours: Depending on various parameters: room inertia, ambient temperature, desired temperature, the thermostat calculates and optimises the programming for each heating period whether set to Comfort or Savings (Eco):
In OPTI ECO mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum energy savings throughout the ECO programme.
In this mode, a slight drop in the temperature level at the beginning and end of the ECO period is allowed to maximise energy savings. The processor within the thermostat stops the boiler operation at the optimum time to slightly reduce the setpoint temperature before the end of the occupancy period.
In this mode, a slight drop in the temperature level at the beginning and end of the comfort period is allowed to maximise energy savings.
In OPTI COMFORT mode, the thermostat’s inbuilt algorithm optimises in order to guarantee maximum comfort during the COMFORT programme. The processor within the thermostat starts the boiler operation at the optimum time to achieve the setpoint temperature at the start of the occupancy period.
In this mode, the priority is given to anticipating and maintaining the comfort temperature during periods of occupancy.
Optimisation choice
The OPTI COMFORT mode is activated by default.
Display disappears on thermostat. Check that the wiring is well done. All electrical installation work should be carried out by a suitably qualified Electrician or other competent person.
The heating does not come on or does not go off.
The thermostat is in Auto Mode but programs are not being executed by the boiler:
Environment:
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2016 No.1101 (Electrical
Equipment safety Regulations), ), 2016 No.1091 (Electromagnetic Compatibility Regulations), 2012 n’3032 (ROHS) and following designated standards:
Neomitis Ltd: 16 Great Queen Street, Covent Garden, London, WC28 5AH UNITED KING-DOM- contactuk@neomitis.com
EU declaration of conformity: We, Imhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with thee provisions of Directives and harmonized standards listed below: CE
Imhotep Creation: ZI Montplaisir – 258 Rue du champ de courses-38780 Pont-Evêque France contact@imhotepcreation.com
Neomitis Ltd and Imhotep Creation belong to Axenco Group.
Control class and energy contribution, according to ERP 2009/125/EC and related regulations
Class V- PID Room Thermostat, for use with on/off heating devices.
Electronic room thermostat that controls both the cycle time of the thermostat and the ratio between on and off periods during the same cycle of the heating device, depending on the room temperature. PID control reduces the average water temperature, improves the accuracy of room temperature control and increases system efficiency.
The symbol, affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE
2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.
NEOMITIS LIMITED – 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 –
Fax: +44 (0) 2071 250 267-
E-mail: contactuk@neomitis.com
www.neomitis.com
Download manual:
Neomitis RTE7SD PROGRAMMABLE ROOM THERMOSTAT Installation Instruction
OTHER MANUALS:
Neomitis RTE7SD PROGRAMMABLE ROOM THERMOSTAT Operation Instruction
Neomitis RTE7SD PROGRAMMABLE ROOM THERMOSTAT Product Specifications Guide
Neomitis RTE7SD PROGRAMMABLE ROOM THERMOSTAT Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…