WIRELESS DIGITAL 7 DAY PROGRAMMABLE ROOM THERMOSTAT AND RECEIVER
MOUNTING OF WALL MOUTING PLATE
MOUNTING OF THE RECEIVER
Recommended locations for your thermostat. To ensure that your thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc. NB: In order to ensure proper operation of the product, ensure that the thermostat is not positioned near to an area that could be affected by interference from another source. E.g.: a wireless transmitter or receiver, TV, PC, etc.
On the wall
On the table stand
Note: the receiver is usually located near your boiler. If you want to check the signal strength, move the mode slider to position and then press and release the RF test button. RF icon blinks for 10 seconds then signal strength appears. 10 is the best signal strength.
WHAT IS OPTIMISATION- OPTIMUM START?
Historically, most UK heating systems waste vast amounts of energy by firing unnecessarily early for most of the year. Homeowners tend to set their boiler on times based on when they wake up by guessing what time they feel that their boiler should fire in order to reach the requested target temperature; for example, turning the boi- ler on at 6 am in order to have a warm room/ home by their wake up time at 7am. Dual function optimization, priority to comfort or energy savings, the choice is yours: Depending on various parameters: room inertia, ambient temperature, de- Sired temperature, the thermostat calculates and optimizes the programming tor each heating period whether set to Comfort or Savings (Eco)
In OPTI COMFORT mode, priority to comfort
In OPTI ECO mode, priority to energy savings
HOW DOES OPTIMUM START WORK?
Optimum Start works on a daily basis. You set the time that you want to be warm and Optimum Start will do the rest; for example – if you wake up at 7:30AM, then set your thermostat’s start time for 7:30AM. Optimum Start ensures that you are warm when you want to be (and not before), reducing wasted energy and saving money (up to 10% of energy costs). To change the optimisation type, refer to the installation instructions/ advanced ins- taller settings.
ADVANCED INSTALLER SETTING
Access
Move the mode slider to position. Select the Programming slider position and press Enter for 5 seconds to go into the dedicated installer setting.
Set 12/24 hours clock
Enable/disable automatic summer/winter change over
Set C/’F temperature
Set calibration
Program lock
Select 2 points/TPI
Note regarding the Advanced installer settings: If MODE slider is moved or no press/ rotation for 15 seconds, it will discard changes and exit installer mode.
Overview
Dual function optimization, priority to comfort or energy savings, the choice is yours:
Depending on various parameters: room inertia, ambient temperature, desired tem- perature, the thermostat calculates and optimizes the programming for each heating period whether set to Comfort or Savings (Eco)
Optimisation Choice
Turn the dial to select the desired mode:
Display disappears on thermostat.
The heating does not come on or does not go off.
Radio transmission is not working properly:
1-The receiver is not picking up the code sent by the thermostat.
2-The receiver does not recognize transmitter’s code.
3- The receiver or the transmitter is affected by interference:
You want to change the operating mode but when you move the mode slider nothing happens.
The thermostat is in Auto Mode but programs are not being executed by the boiler:
The radio link between the thermostat and the receiver is lost.
The thermostat does not control properly.
Receiver:
Maximum range in the home: 15m is typical but this varies depending on the building construction eg plasterboard lined with metal foil the number of walls and ceilings that the signal has to pass through and by the surrounding electromagnetic environment. Signal sending: every 10 minutes, maximum time-lag 1 minute after set-point temperature has been changed.
Environment
N.B.: this room thermostat is one part of a complete radio system and will only work with the 230V AC receiver.
UKCA declaration of conformity: We, Neomitis Ltd, hereby declare under our sole responsibility that the products described in these instructions comply with statutory instruments 2017 No. 1206 (Radio Equipment Regulations), 2012 n°3032 (ROHS) and following designated standards listed below:
Neomitis Ltd: 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM- contactuk@neomitis.com
EU declaration of conformity: We, Imhotep Creation, hereby declare under our sole responsibility that the products described in these instructions comply with the provisions of Directives and harmonized standards listed below:
RED:
Control class and energy contribution, according to ERP 2009/125/EC and related regulations
Class IV- PID Room Thermostat, for use with on/off heating devices. Electronic room thermostat that controls both the cycle time of the thermostat and the ratio between on and off periods during the same cycle of the heating device, depending on the room temperature. PID control reduces the average water temperature, improves the accuracy of room temperature control and increases system efficiency.
The symbol, affixed on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources.
DOWNLOAD MANUAL
NEOMITIS RT7RFBPLUS Wireless Programmable Room Thermostat INSTALLATION Instruction
OTHER MANUALS:
NEOMITIS RT7RFBPLUS Wireless Programmable Room Thermostat OPERATING Instruction
NEOMITIS RT7RFBPLUS Wireless Programmable Room Thermostat INSTALLATION Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…