Many thanks for your selection of our products and services, and also for your trust and support to us.
earch for “Smart Life” Download the Wifi App with the following icon
For other languages, please scan the QR code above.
Support:service@moeshouse.com
Note: Cellphone and gateway must connect under the same WIFI router.
No: | keys | Represent |
D | 1.Short press to switch manual mode and auto mode 2.Long press to access setting interface3.Confirm key | |
E | – | 1. Decrease key 2. Long press to lock/unlock keys |
F | + | 1. Increase Key2. Long press access Boost function setting |
Install the actuator with the valve and power-on, all of the icons appear, and 3s later display program version NO.
Note: after actuator self-testing, under normal working status,if need to modify time, please choose
Continuous click
Error Code | Description |
E1 | Route is too short: in the adjustment process, the pin was stuck before it reach the destination of 2mm |
E2 | The temperature sensor is opened or damaged |
Flashing indicates low battery | |
Display version No. After power on,long displays means mould works,flashing means mould error. |
Note: After malfunction is solved press to self-testing again
Holiday mode: press 3s access to the setting interface, press -or+ until flashing,then press to confirm and enter temperature setting, press -or+ to adjust the value, press confirm and enter days setting press or to adjust the value. If you want to cancel holiday mode, press
Ventilation and energy saving: ventilation and energy saving function is defaulted off, if you want to open this function, please set in advanced options(The default settings will be restored when the battery is replaced )
BOOST: Press and hold+ access to BOOST, pressing any key to cancel BOOST mode
Press
period | Default period | Default temperature |
1 | 6:00-8:00 | 20℃ |
2 | 8:00-11:30 | 15℃ |
3 | 11:30-12:30 | 15℃ |
4 | 12:30-17:30 | 15℃ |
5 | 17:30-22:00 | 20℃ |
6 | 22:00-6:00 | 15℃ |
Press IIIabout 3-5s to access to setting interface, press -or+ until flashing,
Symbol | Setting item | Parameter | default |
A1 | Measuring temperature correction | -9-+9°C | 1°C accuracy correction |
A2 | Window ventilation function | 1:display means close window ventilation function close,presskey display 5°C means this function open(tempera- ture setting range: 5-25°C) | 1.default of power on is means close 2.:display 0:15 means valve closing time 15 minutes |
2:Valve closing time:0:05-1:00,timing starts when the valve is fully closed | |||
A3 | Automatic lock if no operation more than 10 minutes | 0:close 1:open | 0 |
A4 | The minimum limit of the setting temperature | 1-16°C | 5°C |
A5 | The maximum limit of the setting temperature | 16-70° | 35°C |
A6 | Extend BOOST running time, increase 100s for press+ every time | 100s-900s | 300(display 30) |
A7 | Check valve opening | 99 mean valve open 100% 5 mean valve open 5% Each increment is 5% | |
A8 | Heating start/stop Temperature hysteresis | 0.5-1.5 | 1 |
A9 | Display mode | 0:vertical display 1:horizontal display | 0 |
AA | Reset | Display 88, using -or+ to change to 00, press iii to reset, all of the icons appear means reset successfully. |
DOWNLOAD MANUALS:
MOES TS0601 Smart Radiator Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…