Midea

Midea KJR-29B-BK-E Wireless THERMOSTAT USER MANUAL

Midea KJR-29B-BK-E Wireless THERMOSTAT

Wired controller specifications

Model KJR-10B/DB(T)-E
Power Supply Voltage 5.0V DC
Ambient Temperature Range -5°C~43°C
Ambient Humidity Range RH40%~RH90%

Performance Features

  • Operating mode: Cool, heat, dry, fan and auto.
  • Set the mode through buttons.
  • Indoor setting temperature range: 17°C ~30°C.
  • LCD (Liquid Crystal Display).
  • Touch-style key

Function summarize
KJR-29B is the touch-style key-wired controller.

New function Basic function
Air filter cleaning reminder function ON and OFF the air-conditioner
Indoor unit address setting function Auto-restart function
Remote control receiver function Time ON and Time OFF setting
Lock the wired controller Clock setting
26℃ operation shortcut setting and 26℃ operation lock Setting the Operating mode, Temperature
Follow me The fan speed and Swing functions

Wired controller appearance

Remote signal-receiving function
There is the signal receiver for the wireless remote controller on the KJR-29B. You can use the wireless remote controller to control the air-conditioner through the wired remote controller when the system has been powered on.

Notes: The wired controller will not receive the swing controlling instruction. For the indoor unit with swinging function, you can directly use the remote controller to control swinging through the display panel of the indoor unit, or use the swing button on the wired remote controller to control the indoor unit for swinging.

ON/OFF Button
Press the ON/OFF button to control the indoor unit on and off status. When the unit is turned off, press the ON/OFF button, the unit will be turned on and the operating icon lights up. When the unit is turned on, press the ON/OFF button, the unit will be turned off and the operating icon lights off.

Mode Button
Press the mode button to set the operating mode, after each button press the operation mode will circle as follow:

Fan speed setting
Under COOL, HEAT and FAN modes, press the fan speed button can adjust the fan speed setting. After each fan speed button press will circle as follow:

AUTO→LOW→MID→HIGH→AUTO

Under AUTO and DRY modes, the fan speed is not adjustable and the default fan speed is auto

Temperature setting
Under AUTO, COOL, DRY, and HEAT modes, press the Temp adjust Up/Down buttons to set the temperature, the adjusting range is 17℃~30 ( ℃ or 62℉~88 ). The setting temperature cannot be adjusted under FAN mode. ℉

Timer on and Timer offsetting
Press the timer/clock setting button, then enter into the timer on setting status, and the screen will display the timer icon . You can press Temperature setting buttons to adjust the time. When the time setting is less than 10 hours, each press the Temp setting buttons will increase or decrease by 0.5 hours. When the timer setting is more than 10 hours, each press Temp setting buttons will increase or decrease 1 hour, the maximum timer setting is 24 hours. After finish adjusting the time on set, press the 26℃/OK button or wait for 5 seconds to confirm and exit the time on setting.

Notes: If the wired remote controller has been set timer on/ off, press the ON/OFF button to turn on/ turn off the unit then the timer will be canceled simultaneously.

Clock setting
Long press the timer/clock setting button for 3 seconds, and then enter into the clock setting status. The hour position of the clock will flash, and can press Temp setting buttons to adjust the hour value. After finish the hour setting, press left button or right button to switch to minute position setting, then the minute position will flash, press Temp setting buttons to adjust the minute value. After finish the clock setting, press the button or wait for 5seconds to confirm and exit the setting state.

26℃/OK button
Under AUTO, COOL, DRY, HEAT modes, press the 26℃/OK button can set the operating temperature to 26℃. Long press this button for 3 seconds, the wired controller will lock the setting temperature to 26℃, and the locking icon will be lighted up. Under the 26℃ operation locking state, the wired controller cannot adjust the setting temperature through the temperature setting buttons, and also will not respond to the temperature adjusting instruction from the wireless remote controller. Long press 26℃/OK button for 3seconds, can unlock the 26℃operation locking state.

Wired controller locking
Press the temperature adjusting UP and DOWN buttons simultaneously, the wired controller enters into locking state, and the locking icon will be lighted up. Under the locking state, the wired controller will not respond to buttons by pressing and the control instruction from the wireless remote controller. Simultaneously press temperature adjusting buttons again can cancel the locking state.

Air filter cleaning reminding function
The wired controller records the total running time of the indoor unit, when the accumulated running time reaches the pre-set value, air filter cleaning reminding icon will be lighted up, to remind that the air filter of the indoor unit needs to be cleaned. Long press left button for 3 seconds, and clear the reminding icon and the wired controller will re-accumulate the total running time of the indoor unit.

Notes: The default setting value of reminding function is 2500 hours, and it can change to be 1250 hours, 5000 hours or 10000 hours. The setting methods please refer to the installation manual.

Swing Function
If the indoor unit supports swing function, press the right button to adjust the air outlet direction of the indoor unit. Long press this button for 3 seconds can turn on or turn off the auto-swing function. When the auto-swing Control system function is turned on, the swing icon will be lighted up.

Follow me function

When the system is running and the operating mode is AUTO. COOL or HEAT, press the left button will activate the Follow Me function. Press left button again will cancel follow me function. When the operating mode is changed, and then will cancel this function as well. When the Follow Me function is activated, the icon will be light up, and the wired controller will display room temperature read from the local sensor, and transmit the temperature value to the indoor unit every 3 minutes.

Setting addresses

  • Press the Temp. UP and DOWN button simultaneously for more than 8 seconds, then the controller gets into address setting mode.
  • In the address setting mode, there are 2 main functions:
  • Querying address: Press MODE button, the corresponding indoor unit will display its address.
  • Setting address: Use the UP and DOWN buttons to choose an address you want. Then press the FAN button to set the indoor unit’s address. The corresponding indoor unit will display the new address and record it. After about 4 seconds, this displaying will fade out and indoor units turn to normal display mode.
  • After setting addresses, users can press the 26℃/OK button can exit the address setting mode.
  • After each setting address and enter the query / set mode again, it will display the last set of address, but if re-power, this address will be cleared.
  • In the address setting mode, wired controller does not respond to any command from remote controller

Preparation before Installation:
Make sure the following pasts has been prepared.

NO. Name QTY. Remarks
1 Wired Controller 1 /
2 Cross round heat wood

Mounting Screw

3 M4×20(For mounting on the wall)
3 Cross round heat

mounting Screw

2 M4×25(For Mounting on the electrical switch box)
4 Installation Manual 1 /
5 Owner’s Manual 1 /
6 Plastic expansion pipe 3 For Mounting on the Wall
7 Plastic screw bar 1 For fixing on the 86 electrician box
8 Switching wires for

signal receiving board

1 For connecting the signal receiving board and 4-core shielding wire
9 Switching wires for wired

controller signal

1 (If needed) For connecting the main control panel and 4-core shielding wire

Prepare for the following at installation site.

NO. Name Qty.(embedded into wall) Specification remarks (only for reference) Remarks
1 4-core Shield Cable 1 RVVP-0.5 mm2×4 0.05 mm2×5 cable

no more than 12M

2 86 electrician box 1 / /

3

Wiring Tube (Insulating Sleeve and Tightening

Screw)

1

/

/

Dimensions

Wiring principle sketch

Wiring figure

Connect two terminals of embedded 4-core shielding wire with the switching wires of wired remote controller and signal receiving board. Make sure the sequence of 4 terminals (A/B/C/D) should correspond to the wire sequence of signal switching wires (A/B/C/D).

If embedded 4-core shielding wire cannot go through the wired controller, it can use signal switching for connection and make sure the wires are reliable and firm. The tightening torque range of the screw is0.8~1.2N .m (8~12 kgf . cm).

Back cover installation

  • Use straight head screwdriver to insert into the buckling position in the bottom of a wired controller, and spin the screwdriver to take down the back cover. (Pay attention to spinning direction, if not you maybe damage the back cover.)
  • Use three GB950-86 M4X20 screws to directly install the back cover on the wall.
  • Use two M4X25 GB823-88screws to install the back cover on the 86 electrician box, and use one GB950-86 M4X20 screw for fixing the wall
  • Adjust the length of two plastic screw bars in the accessory to be the standard length from the electrical box screw bar to the wall. Make sure when install the screw bar to the electrical box screw bar, make it as flat as the wall.

Notes:

  • Use cross-head screws to fix the wired controller bottom cover in the electric control box through the screw bar. Make sure the wired controller bottom cover is on the same level after installation, and then install the wired controller back to the bottom cover.
  • Fasten the screw will lead to deformation of the back cover

Wiring

Wiring, three outlet positions

Avoid water enters into the wired controller, use trap and putty to seal the connectors of wires during wiring installation. When under installation, reserve a certain length of the connecting wire for convenient to take down the wired controller while during maintenance.

Front cover installation

  • After adjusting the front cover and then buckle the front cover; avoid clamping the communication switching wire during installation.
  • Correct install the back cover and firmly buckle the front cover and back cover, if not you maybe make the front cover drop off.

Wired controller initial parameters setting

  • Change the related functions of the controller by adjusting the initial parameters, details refer to table 1
  • The wired controller initial parameter includes two codes “XY”, the first code “X” means function class, and the second code “Y” means the detailed configuration of this function.

Setting method

  • simultaneously press the “Mode” and “Fan” buttons of the wired controller for 5 seconds to enter the parameter setting state;
  • The value of this first code “X” is “0”; press the temperature setting button UP and DOWN to adjust the second code value;
  • After setting the second code value, press 26/OK button to switch the first code to the next value;
  • When the first code value is “6”, press the 26/OK button again to exit the parameters set.
  • The parameters setting function only under the situation which needs to adjust the default functions’ setting states; otherwise there is no need to do the setting.
First code Functions Second code
0 1 2 3 4
0 Cool-only/ Cool-Heat

selection

Cool-Heat

(Default)

Cool-only / /

1

Indoor unit communication

address setting

Yes (Default)

None

/

/

/

2 Auto-restart Yes

(Default)

None / / /
3 Air filter cleaning

reminding function

Cancel the

reminding function

1250 hours 2500 hours

(Default)

5000hours 10000

hours

5 Remote receiving

function

Yes

(Default)

None
6 Centigrade/

Fahrenheit display

Centigrade Fahrenheit / / /

REFERENCE:

DOWNLOAD MANUALS:

Midea KJR-29B-BK-E Wireless THERMOSTAT USER MANUAL

Midea KJR-29B-BK-E Wireless THERMOSTAT USER MANUAL

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago