The MCO Home Z-Wave thermostat MH7H-EH is suitable for controlling electric underfloor heating and other electric heating devices such as infrared heating panels, fan heaters or connectors. With the integrated Z-Wave module, this thermostat can be integrated into many Z-Wave enabled home automation systems. Thanks to the Z-Wave standard, products from a wide range of manufacturers can be used together in a wireless network (Z-Wave-capable Smarthome control unit required, please check compatibility in advance). This means that the MCO Home Z-Wave thermostat can also be used with many other Z-Wave products from other manufacturers in a common Z-Wave radio network. Alternatively, the thermostat can also be set and operated without a Z-Wave central unit using the device buttons.
Safety instructions and measures
Mounting and installation diagram
The thermostat is intended for indoor mounting only. It is recommended to mount the thermostat at a height of approx. 1.5 m above the floor, where it corresponds approximately to the average room temperature. It should be protected from direct sunlight, covers or heat sources to avoid incorrect temperature readings.
Switching On/Off
After applying power, the unit displays “OFF”, all outputs are forcibly switched off. Touch key 3 to switch the operating mode (Manual / Off / Automatic). Confirm the selection made by touching key 2. After switching on, the unit displays the day of the week, time, operating mode, current temperature, output status, etc.
Note: If the backlight has gone out, please press key 3 first to switch on the backlight. Then press the 3 key again for the corresponding operating mode.
Setting the temperature
In normal operating mode, press the S4 or S5 key to enter the temperature setting interface. The setting range is from 5-37°C. Press the S4 or S5 keys to set the value. Press the S3 key or wait 25 seconds without pressing a key so that the setting is saved and the unit returns to the normal operating interface.
Key lock
If you press the S1 and S4 buttons for a long time during normal operation, a
Operating mode Manual / Automatic
In the normal display interface, you can switch between manual and automatic mode by touching the S3 key. Pressing the S2 key saves the setting. Automatic mode: The unit automatically follows the preset time periods and temperature settings. Manual mode: The appliance follows the manual temperature settings.
Vacation mode
Press and hold the S2 button while in manual or automatic mode to activate vacation mode. When vacation mode is active, a
Setting the time
In the normal work interface, keep the S1 key pressed for a long time to enter the time setting. Then press the S4 or S5 buttons to set the “week, hour and minute” parameters and confirm each entry with the S1 button.
Setting switching times and temperatures for automatic mode
In the normal work interface, briefly press the S1 key to activate the setting of the time periods. Four time periods can be set for each day of the week. Press the S2 key to switch between “hours, minutes, temperature value”. Press the S4 or S5 button to change the value. After you have finished setting the 4 time periods on Monday, press S1 and proceed in the same way to set the time periods of the next days. After all time periods have been set, press S1 or wait 25 seconds without pressing any buttons to save the setting and return to the normal display. The unit will then operate with the new setting.
Default Settings: | Day | Period 1 | Period 2 | Period 3 | Period 4 | ||||
Mon – Fri | 5:00 | 28°C | 7:00 | 24°C | 17:00 | 28°C | 22:00 | 24°C | |
Sat – Sun | 5:00 | 28°C | 9:00 | 24°C | 17:00 | 28°C | 22:00 | 24°C |
High temperature protection
Frost protection function (optional)
Note: If the unit is not connected to an external temperature sensor, only the indoor temperature symbol is displayed. If the unit is connected to an external temperature sensor, it displays the indoor temperature and the high temperature protection symbol.
Humidity display
In the normal work interface, press and hold the S1 and S5 keys to enter the humidity display. If you long press the S1 and S5 buttons again, the unit will return to the normal display.
Z-Wave operation
Advanced settings
When the unit is switched off (OFF), you can access the advanced settings by simultaneously pressing the S3 and S5 buttons for a long time. This level is secured with the code 1234. You can change the numerical values with keys 4 and 5. With key 3 you jump to the next digit. As soon as you have set the code 1234 in the display, press key 2 to confirm.
The parameters that can be set are listed below:
Z-Wave Parameters
ASSOCIATION GROUP
PARAMETER SETTING
Disposal note
Do not dispose of this appliance in household waste! Electronic devices must be disposed of in accordance with the Waste Electrical and Electronic Equipment Directive via the local collection points for waste electronic equipment.
Note on conformity
The CE mark is an over-the-counter mark that is addressed exclusively to the authorities and does not imply any assurance of properties.
Documentation © 2021 Mi-Heat Heizsysteme GmbH
All rights reserved. No part of this manual may be reproduced or duplicated in any form without the written consent of the publisher. It is possible that this manual contains typographical defects or printing errors. We accept no liability whatsoever for errors of a technical or printing nature and their consequences.
Download Manual:
MI-HEAT MH7H-EH Z-Wave Thermostat INSTALLATION INSTRUCTIONS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…