The thermostat is designed for control of electric heating devices (Built in sensors for measuring room temperature and external sensor for high temperature protection , to prevent heating device burned due to high temperature).
Anti-frozen function
In the state of shutdown, the thermostat will turn on the heating device automatically When the room temperature is below 5℃. when the room temperature is above 7℃, the thermostat will turn off the heating device automatically.
Programming: 6 –event time and temperature
In the shutdown state, long press mode key “
Advanced setting (qualified person preferred)
Press” M “and”V “at the same time to enter the mode of advanced setting immediately when thermostat is turned off. The following seven functions can be chosen by” M “key
Mounting Location Recommended
The heating thermostat should be mounted on the wall with air flowing freely around. Warning: The mounting location should not be influenced by other heat source(e.g. sunlight), air flow through doors& windows or temperature of outer wall.
Common failure handling
Failure | Handling |
Crash | 1.Check the power supply wiring is correct or not . 2.Check the power key . |
LCD display garbled | 1.The shell is deformed after installation,can be reinstalled. |
Display normal No output | 1. Check whether the wiring between the MPU and the power board is damaged. 2.Check whether the null line of live line is connected wrong. |
Remote failure | Check if the remote control battery has enough power , if not replace the battery. |
Temperature display error | Adjust the panel temperature display by the first option in the Advanced tab. |
Sensor failure | Check the sensor for damage Er1: Built-in sensor disconnected or fault with it. Er2 External sensor disconnected or fault with it. |
Icon Description
Thermostat networking steps
Press and hold the up and down keys for about 5 seconds when the thermostat is turned off . When you hear the buzzer ringing 3 sounds, the thermostat enters the distribution network interface. After the screen displays full display(or press the power button to exit)the thermostat has entered the network initialization status .When the WiFi symbol ” ” of the thermostat does not flash, it indicates that the connection is successful. Please note that the router or the corresponding WiFi device is turned on and within 5 meters of the thermostat.
Mobile phone networking steps:
Before configuring WIFI , please make sure your phone is connected to 2.4GHz WIFI.
Thermostat and mobile phone Exit the network:
Press and hold the up and down button for about 5 seconds while the thermostat is off. When the buzzer sounds 3 times into the distribution network interface, the screen displays full display. At this time (or press the power button to exit) the control panel has entered the network exit state (also the distribution network state).
DOWNLOAD MANUALS:
MANOMANO ME81AH Heating Thermostat User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…